2. Introducing SCPI Commands

In 1975, the IEEE standardized a bus developed by Heweltt-Packard originally called HPIB (Hewlett-Packard Interface Bus), later changed to GPIB (General Purpose Interface Bus). The standard was called IEEE 488 (IEEE 488.1) and it defined mechanical aspects of the bus. The later IEEE 488.2 defined its protocol properties. What was missing were set of rules between the manufacturers on commands to control the instruments. Sometimes these varied even between different models from the same manufacturer.

In 1990 SCPI Consortium released the first SCPI standard (Standard Commands for Programmable Instruments) as an additional layer for the IEEE-488.2 standard.

SCPI commands are ASCII strings, which are sent to instrument over the physical communication layer. They can perform:

  • Set operations, for example the *RST command (resetting the instrument).
  • Query operations, for example the *IDN? query (querying the instrument’s identification string).

Some SCPI commands exist as both set commands and query commands. An example is an oscilloscope’s acquisition time command "TIMebase:ACQTime". You can set it with the SCPI command "TIM:ACQT 10ms", and also query its current value with the "TIM:ACQT?".

The format mentioned in Rohde & Schwarz user manuals e.g.: "TRIGger<m>:LEVel<n>[:VALue] <Level>" is called canonical form. Here are the most important rules to remember:

  • The parts within square brackets are not mandatory and can be left out.
  • The capital letter parts are mandatory; the small letters can be omitted. This is called short form. An example of the above command in the short form is "TRIG1:LEV2 3.5". You can use either the short form, or the long form "TRIGGER1:LEVEL2 3.5", but nothing in between, e.g. "TRIGGE1:LEVE2 3.5".
  • The SCPI commands are case-insensitive. You can also use the short form "trig1:lev2 3.5" or or the long form "trigger1:level2 3.5"
  • Combine multiple commands into one string using selmicolon ';'. For example, a combined string of "TRIG1:SOUR CH1" and "TRIG1:LEV2 3.5" is "TRIG1:SOUR CH1;LEV 2". Notice that the second command does not have the "TRIG1:" part. The reason is, that the command tree path does not change within one string. If you want to reset the command tree path to the root, use the colon character at the beginning of the second command: "TRIG1:SOUR CH1;:CHAN2:STATe ON".
  • Create query forms by adding a question mark, mostly to the end: "TRIG1:LEV2?" Sometimes there is an additional parameter placed after the question mark. There must be a space character between the question mark and the additional parameter. For example: "TRACE:DATA? ALL"
  • Numeric parameters without specifying the units are considered based units. In our case, the numeric parameter 3.5 means 3.5 Volts.

The complete SCPI standard is available here: SCPI-99

Rohde & Schwarz instrument user manuals contain a section called Remote Control Commands. It contains general explanation, conventions used and all the SCPI commands supported by the instrument. It also describes whether a command is available as a set command or a query command or both. There are also many SCPI programming examples included. The screenshot below is taken from the RTO online version of the user manual:

How do you find a SCPI command in our User Manual? Although you can always use full text search, the fastest way is to go to chapter List of Commands. It contains alphabetically sorted list of all the SCPI commands and cross-references to their descriptions:

CH2_UserManual_ListOfCommands_16x9.png

Chapter 3 explains how you can actually connect to your instrument, send SCPI commands and read the instrument responses.

Запросить информацию

У вас есть вопросы или вам нужна дополнительная информация? Просто заполните эту форму, и мы свяжемся с вами в ближайшее время..

Я хочу получать информацию от Rohde & Schwarz по

Согласие на получение маркетинговых материалов

Что именно это означает?

Я соглашаюсь с тем, что ROHDE & SCHWARZ GmbH & Co. KG и предприятие ROHDE & SCHWARZ или его дочерняя компания, указанная на данном Веб-сайте, может обращаться ко мне выбранным способом (по электронной или обычной почте) с целью маркетинга и рекламы (например, сообщения о специальных предложениях и скидках), относящейся в числе прочего к продуктам и решениям в области контрольно-измерительной техники, защищенной связи, мониторинга и тестирования сети, вещания и средств массовой информации, а также кибербезопасности.

Ваши права

Настоящее заявление о согласии может быть в любое время отозвано путем отправки электронного письма с темой «Unsubscribe» (отказ от подписки на рассылку) по адресу: news@rohde-schwarz.com.Кроме этого, в каждом отправляемом вам письме имеется ссылка на отказ от подписки на рассылку будущих рекламных материалов.Дополнительная информация об использовании персональных данных и процедуре отказа от их использования содержится в Положении о конфиденциальности.

Обязательное поле Предоставляя свои персональные данные, я подтверждаю их достоверность и свое согласие на их обработку Обществом с ограниченной ответственностью «РОДЕ и ШВАРЦ РУС» (ОГРН 1047796710389, ИНН 7710557825, находящемуся по адресу: Москва, Нахимовский проспект, 58) в следующем объеме и следующими способами: обработку с использованием средств автоматизации и без таковых, сбор, систематизацию, классификацию, накопление, хранение, уточнение, обновление, изменение, шифрование с помощью любых средств защиты, включая криптографическую, запись на электронные носители, составление и переработку перечней и информационных систем, включающих мои персональные данные, маркировку, раскрытие, трансграничную передачу моих персональных данных, том числе, на территории стран всего мира, передачу с использованием средств электронной почты и/или эцп, в том числе, передачу с использованием интернет-ресурсов, а также обезличивание, блокирование, уничтожение, передачу в государственные органы в случаях, предусмотренных законодательством, использование иными способами, необходимыми для обработки, но не поименованными выше до момента ликвидации / реорганизации Компании либо до моего отзыва настоящего согласия.

Ваш запрос отправлен. Мы свяжемся с вами в ближайшее время.
An error is occurred, please try it again later.