R&S®ENY81 Coupling Network

For measurement of asymmetrical (common-mode) disturbance voltage

Key facts

  • Eight-wire network
  • Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz)

Brief description

The R&S®ENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs.

Specifications

Frequency range
Radio disturbance measurements R&S®ENY81

Key facts

  • Eight-wire network
  • Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz)
  • Compliance with CISPR 16-1-2
  • Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces
  • High transmission bandwidth for wanted signal (100 MHz)

Brief description

The R&S®ENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs.

Specifications

Frequency range
Radio disturbance measurements R&S®ENY81 150 kHz to 30 MHz
Asymmetrical impedance
Impedance R&S®ENY81: 0.15 MHz to 30 MHz 150 Ω ± 20 Ω
Phase angle 0.15 MHz to 30 MHz 0° ± 20°
Voltage division factor in asymmetrical circuit 150 kHz to 30 MHz typ. 10 dB ± 1 dB (calibration data supplied)
  > 30 MHz to 80 MHz typ. 10 dB ± 2 dB
Transmission bandwidth 3 dB >100 MHz (for 100 Ω source and load impedances
Longitudinal conversion loss (LCL)
55 dB adapter LCL (dB) 55 dB – 10 log (1 + (f/5)2) dB
  tolerance ±3 dB, for 0.15 MHz ≤ f ≤ 30 MHz
65 dB adapter LCL (dB) 65 dB – 10 log (1 + (f/5)2) dB
  tolerance ±3 dB, for f < 2 MHz, –3/+4.5 dB, for 2 MHz ≤ f ≤ 30 MHz
Decoupling attenuation 150 kHz to 1.5 MHz > 35 dB to 55 dB (increases linearly with logarithm of frequency)
  1.5 MHz to 30 MHz > 55 dB
Crosstalk (PSELFEXT, EUT/AE) 1 MHz to 100 MHz ≥ 61 dB to ≥ 21 dB (increases linearly with logarithm of frequency)
Maximum values
Max. permissible RF input voltage   < 15 V
Max. permissible DC voltage between line and ground   100 V
Max. permissible AC voltage between line and ground   63 V
Max. permissible DC current   600 mA (current on each individual wire of one pair or on different pairs)
Connectors
Output to test receiver/input from signal generator   BNC female
Connectors for EUT and AE   adapter with 1 mm connectors and RJ-11 or RJ‑45 connectors
General data
Temperature range operating temperature +5 °C to +40 °C
  storage temperature –20 °C to +70 °C
Overall dimensions (B × H × T) base unit 105 mm × 65 mm × 110 mm (4.13 in × 2.56 in × 4.33 in)
  base unit with adapters 105 mm × 65 mm × 190 mm (4.13 in × 2.56 in × 7.48 in)
Weight base unit with adapters 520 g (1.15 lb)
  R&S®ENY81 case with basic adapter set 1640 g (3.62 lb)
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website