R&S®NGE100B Power supply series

Reduced to the max

R&S®NGE103B, front view
Open Lightbox
R&S®NGE102B, front view
Open Lightbox
R&S®NGE100B series, rear view
Open Lightbox
R&S®NGE103B, front view R&S®NGE102B, front view R&S®NGE100B series, rear view

Key facts

  • R&S®NGE102B with two or R&S®NGE103B with three channels
  • Max. output power of 66 W with R&S®NGE102B, 100 W with R&S®NGE103B
  • Max. output voltage of 32 V per channel
  • Electronic fuse (OCP), overvoltage (OVP)/ -power(OPP)/ -temperature protection (OTP)
  • USB interface (VCP/TMC), optional LAN (LXI), optional wireless LAN, optional digital I/O (4bit)
  • 3-years-warranty

Reduced to the max

The R&S®NGE100B DC Power supply series consists of robust, high-performance, affordable instruments. They offer high efficiency combined with low ripple plus a variety of comfort functions that are not usually found in this class of power supplies.

Features & benefits

All channels galvanically isolated and earth-free

The circuitry of each single channel is completely separated from the others, there is no connection to chassis ground. This makes it easy to combine the channels to drive bipolar circuitries that might need +12 V/–12 V, for example, and avoids any ground problems in complex DUTs.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Driving a bipolar circuit

Combine channels to drive bipolar circuitries that might need + 12 V and – 12 V, for example, without ground problems in complex DUTs.

Parallel and serial operation

Because all channels are electrically equivalent, they can be combined in serial mode to achieve higher voltages. Up to 96 V can be achieved with the R&S®NGE103B, up to 64 V with the R&S®NGE102B. In parallel mode, the channels can be bundled for higher current. Up to 6 A can be achieved when combining two channels. Using all three channels of the R&S®NGE103B, even 9 A are possible.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Parallel and serial operation

The output channels can be combined in serial or parallel to achieve higher voltages or higher currents.

Protection functions

For each channel, users can separately set the:

  • Maximum current (electronic fuse, overcurrent protection, OCP)
  • Maximum voltage (overvoltage protection, OVP)
  • Maximum power (overpower protection, OPP)

If such a limit is reached, the affected output channel will be automatically switched off and a message will be displayed. The overcurrent protection can be linked to other channels (FuseLink function). In this case, the channel exceeding the maximum current level and all linked channels will be switched off.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Protection functions

If a limit is reached, the affected output channel will be automatically switched off and a message will be displayed.

Color-coding of operating conditions

All operating conditions are shown clearly on the 3.5" QVGA display (320 × 240 pixel), including the output power and the status of any protective functions. Colors indicate the different operating conditions:

  • Active outputs are shown in green when working in constant voltage mode and in red when working in constant current mode
  • Inactive outputs are displayed in white. Whenever a channel is in the setting mode, the number to be set is marked by a blue background.
R&S®NGE100B DC Power Supply Series
Open Lightbox

The operating conditions are marked by colors

Constant voltage is indicated in green, constant current in red, inactive channels are shown in white, a blue background indicates a channel in setting mode.

Connectivity

  • Front connectors with 4 mm safety binding posts
  • USB interface (virtual COM port and TMC class)
  • LAN interface (LXI) with integrated web server (R&S®NGE-K101 option) 
  • Wireless LAN, unique in this class (R&S®NGE-K102 option)
  • Digital trigger in/out (4-bit) on the rear (R&S®NGE-K103 option)
R&S®NGE100B DC Power Supply Series
Open Lightbox

Digital I/O

Channel 1 of the optional digital I/O interface is used as a trigger input.

Available models

Available models

  • Model name

    R&S®NGE102B

    Order number 5601.3800.02

    Number of output channels
    2
    Max. output power
    66 W
    Output voltage per channel
    0 V to 32 V
    Output current per channel
    0 A to 3 A
    Starting at
  • Model name

    R&S®NGE103B

    Order number 5601.3800.03

    Number of output channels
    3
    Max. output power
    100 W
    Output voltage per channel
    0 V to 32 V
    Output current per channel
    0 A to 3 A
    Starting at
Specifications
Electrical specifications
Number of output channels   2/3
Total output power   max. 66 W/100 W
Maximum output power per channel   33,6 W
Output voltage per channel   0 V to 32 V
Maximum output current per channel   3 A
Voltage ripple and noise (20 Hz to 20 MHz)   typ. < 1.5 mV (RMS)
    < 20 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz)   < 2 mA (RMS) (meas.)
Load recovery time*1)   < 200 µs (meas.)
Programming/readback resolution Voltage 10 mV
  Current 1 mA
Readback accuracy (± (% of output + offset)) Voltage < 0.1% + 20 mV
  Current < 0.1% + 5 mA
Special functions
Measurement functions   voltage, current, power, energy
Protection functions   OVP, OCP, OPP, OTP
FuseLink function  
Fuse delay at power-up  
Sense function   -
Sink mode   -
Output sequencing   -
Trigger input/output   -
Arbitrary function   ● (EasyArb)
Analog/modulation interface  
Data logging   -
Display and interfaces
Display   3,5" QVGA
Rear panel connections    
Remote control interfaces   standard: USB; optional: LAN, WLAN
General data
Dimensions (W × H × D)   222 × 97 × 310 mm
Weight   4.9 kg/5.0 kg
Rack installation   R&S®HZC95 option
*1) 10% to 90% load change within a band of ± 20 mV of set voltage.

Available options

General analysis
Product Description
Ethernet Remote Control

R&S®NGE-K101

Order number 5601.2204.03

Description

Ethernet Remote Control

Wireless LAN Remote Control

R&S®NGE-K102

Order number 5601.2210.03

Description

Wireless LAN Remote Control

Digital Trigger I/O

R&S®NGE-K103

Order number 5601.2227.03

Description

Digital Trigger I/O

General accessories
Product Description
19" Rackmount kit

R&S®HZC95

Order number 5800.2054.02

Description

19" Rackmount kit, 2HU,for R&S®HMC family 

Further information

Flyer: Power supplies. Versatile and compact.

Unique features for better results. Different power supply classes. Connectivity – everything you need.

Download now

Teaching-Software for Multi-User Student Labs

The R&S®CDS campus dashboard software simplifies teaching of student groups in laboratories with multiple workbenches.

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

I want to receive information from Rohde & Schwarz via

Marketing permission

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.