Analyze passive low frequency components

With a Rohde & Schwarz oscilloscope

RTM3004

Your task

Vector network analyzers are perfect for analyzing passive or active components, such as filters, amplifiers, mixers and multiport modules. However, low frequency componentdesigners’ requirements include lower start frequencies – sometimes even down to a few Hertz. Traditional network analyzers usually have start frequencies in the kHz range.

Rohde & Schwarz solution

Easily and quickly analyze low frequency response on your oscilloscope with the R&S®RTx-K36 frequency response analysis (Bode plot) option. Characterize the frequency response of a variety of electronics, including passive filters and amplifier circuits. The R&S®RTx-K36 frequency response analysis (Bode plot) option uses the oscilloscope’s built-in waveform generator to create stimulus signals ranging from 10 Hz to 25 MHz. Measuring the ratio of the stimulus signal and the output signal of the DUT at each test frequency, the oscilloscope plots gain and phase logarithmically.

Measurement setup

The frequency response of RF networks is defined as the ratio between the output signal (termed as B wave) over the injected signal (termed as A wave).

Measuring the frequency response of a network requires a source generating signals across certain frequencies. The amplitude and phase of the input signal as well as at the output of the DUT must be measured for the calculation.

Use the Bode plot application to turn your Rohde & Schwarz oscilloscope into a frequency response analyzer.

Device setup

Connect the oscilloscope’s generator and one oscilloscope channel to the DUT input, and another oscilloscope channel to the DUT output.

Setup connection
Setup connection

Start the application:

  • Set start and stop frequency between 10 Hz and 25 MHz and determine the generator output level.
  • Set the points per decade to improve and modify the resolution of your acquisition. The oscilloscope supports up to 500 points per decade.
  • For analyzing the phase and gain shift of digital filters, the R&S®RTx-K36 option allows you to set an additional hold off time before each decade step.
  • Press run to start your measurement. The measurement results are plotted as gain/phase over frequency. Set your markers to your point of interest.

Measurement results

Gain and phase waveforms displayed in the Bode plots represent the transmission function of the DUT. Gain shows the amplitude frequency response frequency range in dB. The phase waveform displays the phase characteristics over frequency, measured in degrees.

Drag markers to the desired positions directly on the plotted trace. A legend displays the coordinates of the markers. To determine the cutoff frequency of a low pass filter, activate two markers. The cutoff frequency is defined as the frequency for which the output of the circuit is 3 dB below the nominal passband value.

Summary

Engineers use oscilloscopes as a primary measurement tool. Equip your oscilloscope with a Bode analysis option to determine the frequency response of passive components.

The R&S®RTx-K36 frequency response analysis (Bode plot) option for the R&S®RTB2000, R&S®RTM3000 and R&S®RTA4000 oscilloscopes provides a low-cost alternative to low frequency network analyzers or dedicated standalone frequency analyzers. With their 10-bit ADC, low noise and 25 MHz generator, the R&S®RTB2000, R&S®RTM3000 and R&S®RTA4000 oscilloscopes ideally meet the high dynamic range requirements of this measurement task.

Frequency response of a bandpass filter
Frequency response of a bandpass filter (blue trace: gain; orange trace: phase)