Key facts

  • Bandwidth: 100 MHz to 1GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 80 Msample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

Starting at 45 700 SEK

  • Promo oscilloscopes
  • 10 years oscilloscopes
  • 3-year warranty extension
  • EDN Hot 100 product

See more of your signal with the power of 10

Designed as daily problem-solving tool, the R&S®RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for all Rohde & Schwarz probes.

  • Four times more vertical resolution than standard 8-bit ADCs
  • Maintains fast sampling rates at all times
  • 10.1" touchscreen with gesture support

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures a vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

40 Msample standard and 80 Msample interleaved

The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.

40 Msample standard memory
Open Lightbox

40 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 80 Msample standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 400 Msample with history function

The R&S®RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size the 400 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis.

400 Msample segmented memory
Open Lightbox

400 Msample segmented memory

Capture the longest time periods with class-leading 400 Msample memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTM-B1 option turns every R&S®RTM3000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and timecorrelated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

4-bit DAC signal change
Open Lightbox

4-bit DAC signal change

The R&S®RTM3000 captures and analyzes analog and digital signals synchronously and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTM-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTM3000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTM3000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

FFT of a square wave
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTM3000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest signal details of a high dynamic signal matter for power measurements. Verification of RDS(on) of a MOSFET is one example. The high ADC resolution of the R&S®RTM3000 oscilloscopes increases the vertical resolution up to 10 bit. Previously unseen signal details become visible and measurable. In the example of RDS(on), it makes it possible to measure the slope of the drain-to-source-voltage while the switch is closed.

Power analysis
Open Lightbox

Power analysis

Analyze the input, output and transfer function of switched-mode power supplies

Available models

Available models
Models
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Starting at

R&S®RTM3002

Order number 1335.8794.02

Bandwidth
100 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
45 700 SEK

R&S®RTM3004

Order number 1335.8794.04

Bandwidth
100 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
54 400 SEK

R&S®RTM3002 + RTM-B222

Order number 1335.8794P22

Bandwidth
200 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
54 700 SEK

R&S®RTM3004 + RTM-B242

Order number 1335.8794P24

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
60 700 SEK

R&S®RTM3002 + RTM-B223

Order number 1335.8794P32

Bandwidth
350 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
94 100 SEK

R&S®RTM3004 + RTM-B243

Order number 1335.8794P34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
112 900 SEK

R&S®RTM3002 + RTM-B225

Order number 1335.8794P52

Bandwidth
500 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
119 200 SEK

R&S®RTM3004 + RTM-B245

Order number 1335.8794P54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
152 400 SEK

R&S®RTM3002 + RTM-B2210

Order number 1335.8794P62

Bandwidth
1 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
142 900 SEK

R&S®RTM3004 + RTM-B2410

Order number 1335.8794P64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Starting at
189 300 SEK
Specifications
Vertical system
Analog channelsR&S®RTM3002; R&S®RTM30042; 4
Digital channels (opt.)16
Bandwidth (-3 dB)R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options)100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise timeR&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options)3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivitymax. bandwidth in all rangesat 1 MΩ: 500 μV/div to 10 V/div
at 50 Ω: 500 μV/div to 1 V/div
ADC resolution10 bit, up to 16 bit with high resolution decimation
DC gain accuracyoffset and position = 0, maximum operating temperature change of ±5°C after self-alignmentinput sensitivity > 5 mV/div: ±1.5 % of full scale
input sensitivity > 5 mV/div: ±2 % of full scale
Acquisition system
Realtime sampling rate2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memorystandard: 40 Msample (80 Msample interleaved)
with R&S®RTM-K15 option: 400 Msample segmented memory
Max. acquisition rate64 000 waveforms/s
(2 000 000 in fast segmented memory mode)
Horizontal system
Timebase rangeselectable between 0.5 ns/div and 500 s/div
Accuracy (after delivery/calibration)±2.5 ppm
Channel-to-channel skew< 200 ps (meas.)
Channel deskew±500 ns
Trigger system
Standard Trigger typesedge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout
Optional Trigger typesI2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,ARINC 429, MIL-STD-1553
Trigger sensitivitywith DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.)
Analysis and measurement functions
Automatic measurements32
Cursor measurements4
Waveform mathematics5 equations math on math (addition, substraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle)
Mask testing
Mask definitionelementary (tolerance mask around the signal)
History and segmented memory
Number of segmentsup to 34 952
Protocol trigger and decode
Supported protocolsI2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429
Waveform generator
Resolution14-bit
Sample rate250 Msample/s
Amplitudehigh Z; 50 Ω20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offsethigh Z; 50 Ω±5 V; ±2.5 V
Arbitrarysampling rate; memory depthmax. 10 Msample/s; 32k points
Logic analyzer (MSO) functionality
Digital input channels16
MSO Memory depthtwo logic probes: 40 Msample for every channel
one logic probe: 80 Msample for every channel
MSO Bandwidth400 MHz (meas.)
MSO sampling rate2.5 Gsample/s
MSO input impedance100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel busesup to 4
General data
DimensionsW × H × D390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight3.3 kg (7.27 lb)
Display10.1" WXGA TFT color display (1280 × 800 pixel)
InterfacesUSB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating systemEmbedded

Available options

General
Product
Description

Order number 1335.8988.02

Description

Mixed signal option, 400 MHz

The RTM-B1 MSO option is a powerful tool for debugging digital designs with a sampling rate of up to 5 GSa/s and a memory depth of up to 20 Msa.

R&S®RTM-B6

Order number 1335.8994.02

Description

Arbitrary waveform generator

Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTM3000 oscilloscope.

Bandwidth upgrade
Product
Description
R&S®RTM-B222

Order number 1335.9003.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 200 MHz bandwidth

R&S®RTM-B223

Order number 1335.9010.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth

R&S®RTM-B225

Order number 1335.9026.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 500 MHz bandwidth

R&S®RTM-B2210

Order number 1335.9032.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 1GHz bandwidth

R&S®RTM-B242

Order number 1335.9049.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 200 MHz bandwidth

R&S®RTM-B243

Order number 1335.9055.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 350 MHz bandwidth

R&S®RTM-B245

Order number 1335.9061.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 500 MHz bandwidth

R&S®RTM-B2410

Order number 1335.9078.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 1 GHz bandwidth

Serial triggering and decoding
Product
Description

Order number 1335.8807.02

Description

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Order number 1335.8813.02

Description

UART/RS-232/RS-422/RS-485 serial triggering and decoding

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Order number 1335.8820.02

Description

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

Order number 1335.8842.02

Description

I²S/LJ/RJ/TDM triggering and decoding

Triggering and decoding of I²S buses

Order number 1335.8859.02

Description

MIL-1553 serial triggering and decoding

Triggering and decoding of MIL-STD-1553 buses

Order number 1335.8865.02

Description

ARINC 429 serial triggering and decoding

Triggering and decoding of ARINC 429 buses

General analysis
Product
Description

Order number 1335.8907.02

Description

History and segmented memory

History and 400 Msample segmented memory.

Order number 1335.8920.02

Description

Power analysis

When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).

Order number 1335.9178.02

Description

Frequency Response Analysis (Bode plot)

The R&S®RTM-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

Order number 1335.9184.02

Description

Spectrum analysis and spectrogram

The spectrum analysis option enhances the powerful FFT capability of R&S®RTM3000 oscilloscopes with spectrogram display

General accessories
Product
Description
R&S®RTB-Z1

Order number 1333.1728.02

Description

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z4

Order number 1335.9290.02

Description

Transit case with wheels for R&S®RTB

R&S®RTB-Z3

Order number 1333.1734.02

Description

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

Order number 1335.7875.02

Description

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

R&S®ZZA-RTB2K

Order number 1333.1711.02

Description

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

R&S®RT-Z2T

Order number 1338.0007.02

Description

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

Passive probes
Product
Description

Order number 1333.2401.02

Description

Passive probe, 500 MHz, 10:1

Order number 1409.7550.00

Description

Passive probe, 500 MHz, 10:1

Order number 1333.1370.02

Description

Passive probe, 38 MHz, 1:1

Active single-ended probes
Product
Description

Order number 1333.0815.02

Description

Active single-ended probe, 1 GHz, BNC interface

Order number 1418.7007.02

Description

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4080.02

Description

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Order number 1410.3502.02

Description

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Product
Description

Order number 1410.4715.02

Description

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4409.02

Description

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Product
Description

Order number 1800.5006.02

Description

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Product
Description

Order number 1333.0873.02

Description

250 MHz passive high voltage probe

Order number 1409.7720.02

Description

400 MHz passive high voltage probe

Order number 1409.7737.02

Description

400 MHz passive high voltage probe

Order number 1800.2307.02

Description

200 MHz High voltage differential probe

Order number 1800.2107.02

Description

100 MHz High voltage differential probe

Order number 1800.2207.02

Description

200 MHz High voltage differential probe

Order number 1800.2007.02

Description

100 MHz High voltage differential probe

Current probes
Product
Description

Order number 1333.0850.02

Description

AC/DC 20 kHz current probe

Order number 1333.0844.02

Description

100 kHz current probe

Order number 1409.8204.02

Description

2 MHZ current probe

Order number 1409.7750K02

Description

10 MHZ current probe

Order number 1409.8210.02

Description

10 MHZ Current probe

Order number 1409.8227.02

Description

50 MHZ Current probe

Order number 1409.7766K02

Description

100 MHZ current probe

Order number 1409.8233.02

Description

100 MHZ current probe

Order number 1801.4932.02

Description

120 MHz current probe

Order number 1409.7772K02

Description

120 MHz current probe

EMC near field probes
Product
Description

Order number 1147.2736.02

Description

E and H near-field probe set

Logic probes
Product
Description
R&S®RT-ZL04

Order number 1333.0721.02

Description

400 MHz logic probe

Probe accessories
Product
Description

Order number 1409.7789.02

Description

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

Order number 1410.4744.02

Description

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.

Application bundles
Product
Description
R&S®RTM-PK1

Order number 1335.8942.02

Description

Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), spectrum analysis and spectrogram (R&S®RTM-K37), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models

R&S®RTM-PK1US*

Order number 1335.9190.02

Description

Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), spectrum analysis and spectrogram (R&S®RTM-K37), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models * ONLY distributed in North America

Application packages
Product
Description
R&S®RTM3K-LSSB

Order number 1335.9149P02

Description

Low-speed serial bus package (R&S®RTM3004, -K1, -K2, -K15, -B1)

Low-speed serial bus package, contains base unit of R&S®RTM3004, trigger and decoding I2C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2), History and Segmented Memory (R&S®RTM-K15) and Mixed Signal Option (R&S®RTM-B1)

R&S®RTM3K-HVP4

Order number 1335.9132P04

Description

High voltage power package (R&S®RTM3004, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3004 and high voltage differential probe R&S®RT-ZHD60

R&S®RTM3K-HVP2

Order number 1335.9132P02

Description

High voltage power package (R&S®RTM3002, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3002 and high voltage differential probe R&S®RT-ZHD60

R&S®RTM3K-PS

Order number 1335.9126P02

Description

Power supply package (R&S®RTM3004, -K31, R&S®RT-ZHD07, R&S®RT-ZC15B)

Power supply package, contains base unit of R&S®RTM3004, Power Analysis Option (R&S®RTM-K31), high voltage differential probe R&S®RT-ZHD07, and current probe R&S®RT-ZC15B

R&S®RTM3000 - Media center

RTM 3000 - Video list
R&S®RTM3000 - Media Center

View more

Application Videos
Oscilloscopes application videos - Media center

View more

Also interesting for you

10 years Rohde & Schwarz oscilloscopes

10 years of Rohde & Schwarz oscilloscope innovation

More information

Oscilloscopes promotion

Oscilloscopes promotion

Choose the right R&S promotion for your individual needs and save your budget

More information

Rohde & Schwarz webinars

Oscilloscope webinar center for digital design and power electronics applications

More information

 Teaching-Software for Multi-User Student Labs

Teaching-Software for Multi-User Student Labs

The R&S®CDS campus dashboard software simplifies teaching of student groups in laboratories with multiple workbenches.

Product information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.