Key facts

  • User Defined Phase
  • Port / Source Independent (ZNA)
  • Automatic True Differential Measurements (ZNA-K61: 0°/180° stimulation signal)
  • Phase Imbalance
  • Amplitude Imbalance

VNA Source Phase Control Options

The VNA source phase control options address the requirement for characterizing devices with defined phase stimulus at the reference plane. These devices include differential amplifiers, mixers, IQ mixers, phase antenna arrays and others. The four coherent sources of the ZVA allow the user to set an arbitrary relative phase between the different test ports. The DDS architecture of the ZNA takes the option a step further, permitting the user to set an arbitrary phase independently for each of the test ports. The vector error calibration extends the phase setting to the reference plane both for the ZVA and ZNA class instruments.

Features & benefits

User Defined Phase with ZNA-K6

Abitrary phase at the reference plane

1. Arbitrary phase for each test port independently
2. Extendable to the reference plane via system error correction

Open Lightbox

User Defined Phase ZVA-K6

Relative arbitrary phase at the reference plane

1. Arbitrary phase difference between test ports
2. Phase difference set relative to a reference port
3. Extendable to the reference plane via system error correction

Open Lightbox

Automatic True Differential Measurements ZNA-K61, ZVA-K6

Direct and Accurate True Differential Measurements

1. Fully automated sweeps
2. True differential stimulus at e ach data point
3. Phase imbalance sweep with fixed frequency and power
4. Amplitude imbalance sweep with fixed frequency and phase

Open Lightbox

Available models

Available models
Models
Supported VNA
Absolute phase at reference plane
Port/source independent
True differential
Amplitude imbalance/phase imbalance
Phase resolution

R&S®ZNA-K6

Order number 1332.5413.02

Supported VNA
Absolute phase at reference plane
Yes, arbitrary
Port/source independent
Yes
True differential
Amplitude imbalance/phase imbalance
No / no
Phase resolution
<0,1°

R&S®ZNA-K61

Order number 1332.5442.02

Supported VNA
Absolute phase at reference plane
0 and 180 degrees
Port/source independent
No, relative to another test port
True differential
Amplitude imbalance/phase imbalance
Yes / yes
Phase resolution
<0,1°

R&S®ZVA-K6

Order number 1164.1540.02

Supported VNA
Absolute phase at reference plane
Yes, arbitrary
Port/source independent
No, relative to another test port
True differential
Amplitude imbalance/phase imbalance
Yes / yes
Phase resolution
0,1°

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.