Key facts

  • Precise transmission loss and reflection measurements plus frequency response in the automotive radar bands (72 GHz - 82 GHz)
  • Spatially resolved transmission phase and high resolution reflection image with a single measurement
  • Extremely short cycle time of 4 seconds ensures high throughput in production
  • VNA-like accuracy due to compliant verification set with plates for transmission loss and reflection verification
  • Internal self calibration, requires no dismounting or external equipment 

Ensuring automotive radome & bumper quality from design to end-of-line-test

The R&S®QAR50 is the ideal tool for accurately testing the quality of automotive radomes and bumpers in the automotive radar frequency range at the end-of-line (EOL). It features sufficient space to easily accommodate bulky bumpers combined with spatially resolved measurements to evaluate the homogeneity of design emblems. Its innovative hardware concept allows for the fastest measurement times on the market whereas the modular software concept allows adaptation to your particular requirements. The R&S®QAR50 delivers radome and bumper testing with speed and precision at a very attractive price point.

Features & benefits

Robust and reliable results

Measurement clusters increase space for your samples

The R&S®QAR50 uses almost 200 receive and transmit antennas to quickly characterize materials, bumpers and emblems. The microwave imaging technology with its electronic focusing allows for a more flexible positioning of the measurement antennas and thus makes space for the important part: your material under test.

The most significant advantage of electronic focusing is the increased robustness of the setup: When using only a single antenna for the received and transmitted signals, the reflected energy needs to exactly return to its origin. The slightest deviation in angle has a massive effect on the measurement value. The larger antenna array of the R&S®QAR50 allows for looser positioning tolerances while still maintaining a precise measurement result. Within the positioning tolerances, the instrument ensures a correct and reliable result. Incorrect sample positioning can even be optically tracked in the resulting images.

Open Lightbox

With it"s clusters hundreds of receive and transmit antennas quickly characterize materials, bumpers and emblems with fully electronic focusing.

Fully electronic focusing

Characterization of bumpers and radomes without mechanical movement.

The microwave imaging capabilities of the R&S®QAR50 allow for a complete characterization of the samples without the need for mechanical movements. The software not only features a spatially-resolved reflection and transmission phase image, but also a frequency-resolved analysis of your equipment under test.

The resulting images allow for a detailed homogeneity analysis of the sample, whilst the time-gated frequency response ensures an optimized product and a constant quality of the manufacturing process.

Open Lightbox

The robust reflection measurement helps keeping track of the correct positioning of your samples in production.

High accuracy and value

Keycode enabled measurement capabilities

The software concept of the R&S®QAR50 allows for flexibility in terms of instrument configuration. With the keycode enabled software options, the instrument can be configured according to the specific measurement requirements.
Starting with precise reflection and transmission loss measurements in the standard software, the instrument can be enhanced with the following measurement capabilities:

  • Frequency response for both transmission and reflection from 72 GHz to 82 GHz in order to allow for constant quality monitoring of the production process
  • High resolution transmission phase imaging enabling homogeneity analysis of the measured parts
  • High resolution reflection measurement for extensive analysis and error tracking in the process

Open Lightbox

The instruments frequency resolved measurement helps maintaining constant production quality.

Fastest measurement times

Cycle times optimized for high throughput production purpose.

The R&S®QAR50 is capable of processing large amounts of data in a short amount of time. Resulting images and frequency plots are available within a handful of seconds. Depending on the selection of parameters and data to be saved, extremely fast cycle times are reachable. This makes the R&S®QAR50 the ideal test solution for high throughput production lines.

Open Lightbox

Get results faster than with any other instrument (< 4 s)

Market leading precision

Traceable results for transmission and reflection measurements

The accuracy and repeatability of measurement equipment needs to be verified on a regular basis. With the help of the DAkkS certified verification set (QAR50-Z44), the R&S®QAR50 can be verified according to national/international standards (*). This ensures a smooth audit processes.
The R&S®QAR50-Z44 enables simple and quick verification of the instrument’ accuracy and repeatability. Both reflection and transmission loss measurement performance of the instrument can be verified. Thus, the QAR50-Z44 allows for regular quality monitoring of the end-of-line (EOL) test equipment.

(*) Available Q3/22

Open Lightbox

DAkkS compliant QAR50-Z44 verification set with plates for transmission loss and reflection verification.

Self calibration capabilities

Calibration without the disruption of disassembling the setup

In order to calibrate standard test & measurement equipment, the instruments must usually be dismounted and setup in a special calibration procedure. Quite different for the R&S®QAR50: The instrument can remain in place.
Using the built-in spherical reflectors, the instrument can calibrate itself within an instant. There is no need to remove, or reposition the measurement setup. This allows for significantly reduced downtimes in case of scheduled maintenance or unscheduled repair.

Open Lightbox

The calibration spheres are directly integrated into the R&S®QAR50, supporting a quick calibrations in-line.

Available models

Available models
Models
Description
R&S®QAR50 vertical polarization

R&S®QAR50 vertical polarization

Order number 1343.0099K02

Description
 Vertical polarization
R&S®QAR50 horizontal polarization

R&S®QAR50 horizontal polarization

Order number 1343.0099K03

Description
Horizontal polarization
Specifications
Analysis and measurement
Frequency rangewithout QAR50-K1076 - 81 GHz
with QAR50-K1072 - 82 GHz
Measurement quantities  1-way transmission loss
Reflection
Transmission phase
Cycle time<  4 seconds
Polarizationvertical / horizontal
Dimension
verification setQAR50-Z44 for transmission loss and reflection
Distance between clusters990 mm
Instrument dimensionsC-shape310 x 1420 x 970 mm
 
U-shape310 x 970 x 1420 mm
 
Weight78kg
Electrical specifications
LicensesCE, UKCA, RCM, FCC*, KC, VDE, CSA*
 
Voltage rating110 - 220V
Power rating< 300 W
InterfacesEthernetSCPI
Service level agreementsavailable worldwide

Available options

Frequency resolution
Product
Description
R&S®QAR50-K10

Order number 1343.2091.02

Description

Frequency response

Frequency range extension to 72-82 GHz for transmission loss and reflection measurement. Detect and trace correct frequency adaptation of material (software license).

Phase image
Product
Description
R&S®QAR50-K20

Order number 1343.2110.02

Description

Phasemask evaluation

Extends the measurement quantities of the instrument to transmission phase. Enables an homogeneity analysis of the radome / bumper (software license).

HD reflection image
Product
Description
R&S®QAR50-K30

Order number 1343.2133.02

Description

HD Reflection

Unlocks the high resolution reflection imaging of the instrument. Supports quick detection of disturbances in R&D and correct DUT positioning (software license).

Verification kits
Product
Description
R&S®QAR50-Z44

Order number 1343.0082.02

Description

Verification set for transmission loss and reflection measurements

Allows the R&S®QAR50 to verify compliance with national and international standards. Ensures the high accuracy and repeatability of your measurement results.

Related resources

Explainer video: Explore the benefits of the R&S®QAR50

Explainer video: Explore the benefits of the R&S®QAR50

Discover why the R&S®QAR50 is the perfect tool for measuring automotive radomes and bumpers throughout the development lifecycle. From early R&D and material characterization through the complex molding processes of design emblems until end-of-line production testing.

More information

Measuring with the R&S®QAR50

Measuring with the R&S®QAR50

Learn more about the QAR50's measurement capabilities and unique features within this 5 minute video.

More information

Webinar: Ensuring automotive radome & bumper quality from design to high-volume production

Webinar: Ensuring automotive radome & bumper quality from design to high-volume production

Learn about how microwave imaging technology can be utilized to provide accurate, 2-dimentional characterisation of radome and bumper quality, accelerate the design cycle and facilitate seamless transition from development in the lab to high-volume production.

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

I want to receive information from Rohde & Schwarz via

Marketing permission

I want to receive marketing or advertising information (e.g. on special offers and discount promotions) from Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the Imprint of this website via Email or Post. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy and the Marketing Permission.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.