R&S®NRP-Z22 Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
- Overview
- Options
- Features & Benefits
- Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -57 dBm to +33 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
- R&S®NRP-Z211 Order No. 1417.0409.02 / 1417.0409.04Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector - R&S®NRP-Z221 Order No. 1417.0309.02Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
- R&S®NRP-Z81 Order No. 1137.9009.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connector - R&S®NRP-Z85 Order No. 1411.7501.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connector - R&S®NRP-Z86 Order No. 1417.0109.40Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector - R&S®NRP-Z86 model .44 Order No. 1417.0109.44Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 44 GHz,
2.4 mm connector
- R&S®NRP-Z27 Order No. 1169.4102.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connector - R&S®NRP-Z37 Order No. 1169.3206.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
- R&S®NRP-Z2 Order No. 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15Sensor Extension Cable
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
- R&S®NRP-Z3 Order No. 1146.7005.02USB Adapter (active)
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
- R&S®NRP-Z4 Order No. 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11USB Adapter (passive)
For all R&S®NRP-Z sensors.
The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus.
Available cable lenghths: Available cable lengths: 2.0m, 0.5m and 0.15m
Available cable length for panel-mount: 1m - R&S®NRP-Z5 Order No. 1146.7740.02USB Sensor Hub
R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.