SMUs for electronic component DC characterization

In addition to general purpose lab power supplies SMUs offer additional features like:

  • Two- or four-quadrant power supply with source/sink operation
  • High resolution, high accuracy
  • Fast response combined with very low noise
  • Enable extrem safe operation of sensitive electronic components
  • Operation as voltage source with current limiter or as real current source with voltage limiter
  • DC, pulsed, sweep or pulsed sweep source/measurement modes
  • Extended synchronization capabilities with other instruments
Rohde & Schwarz source measure units
Product Name
Number of output channels
Max. output power
Output voltage per channel
Max. current per channel
Starting at
Number of output channels
1
Max. output power
60 W
Output voltage per channel
0 V to 20 V;
-20 V to +20 V
Max. current per channel
≤ 6 V: ±8 A, > 6 V: ±3 A
Starting at
ADCMT SMUs with full capability
Product Name
Max. output voltage
Max. current range
Resol. curr./volt. meas.
Resol. curr./volt. setting
Min. pulse width
Max. output voltage
±15(10) V
Max. current range
±1 (4 pulsed) A
Resol. curr./volt. meas.
100 pA / 1 µV meas.
Resol. curr./volt. setting
1 nA / 10 µV
Min. pulse width
50 µs
Max. output voltage
±32 V
Max. current range
±0.5 A
Resol. curr./volt. meas.
100 pA /1 µV meas.
Resol. curr./volt. setting
1 nA / 10 µV
Min. pulse width
50 µs
Max. output voltage
±6 V
Max. current range
±5 A
Resol. curr./volt. meas.
100 pA / 1 µV meas.
Resol. curr./volt. setting
1 nA / 10 µV
Min. pulse width
50 µs
Max. output voltage
4 x ±10 V
Max. current range
4 x ±0.5 A
Resol. curr./volt. meas.
10 pA / 10 µV meas.
Resol. curr./volt. setting
100 pA / 100 µV
Min. pulse width
50 µs
ADCMT SMUs with source/sink capability only
Product Name
Max. output voltage
Max. current range
Source resolution
Resol. curr./volt. setting
Min. pulse width
Max. output voltage
±32 V
Max. current range
±0.22 A
Source resolution
4½ digits
Resol. curr./volt. setting
100 nA / 1 µV
Min. pulse width
20 ms
Max. output voltage
±32 V
Max. current range
±0.22 A
Source resolution
5½ digits
Resol. curr./volt. setting
10 nA / 100 nV
Min. pulse width
20 ms
Max. output voltage
±1200 V
Max. current range
±0.12 A
Source resolution
6½ digits
Resol. curr./volt. setting
1 nA / 10 nV
Min. pulse width
1 s
    0 of 3 Compare products
    Select at least 2 Products
    Discontinued products
    Product Name
    Successor
    Successor
    Successor
    Successor

    Typical applications

    Diode Leak Current Measurement

    SMUs can operate in ISVM (Current Source Voltage Measurement) or VSIM (Voltage Source Current Measurement) modes. Based on it's high resolution and accuracy even smallest leak currents of electronic components can be characterized.

    Diode Leak Current Measurement
    Open Lightbox

    Diode Leak Current Measurement

    Conductive Plastic Low Resistance Measurements

    ADCMT SMUs are well suited for low resistance measurements e.g. at conductive plastics or metallic connectors with up to 10 µV resolution. Some units (6240B) can cancel the thermal EMF at the contact section automatically.

    Conductive Plastic Low Resistance Measurements
    Open Lightbox

    Conductive Plastic Low Resistance Measurements

    Battery-Evaluation

    All ADCMT SMUs can be used for charge/discharge tests of batteries. The applicable battery capacity is determined by the output characteristics of these 4-quadrant-power supplies. The pulse profiles can be defined with minimum 50 µs pulse width of the programmable pulsed current source, which operates for these kind of tests as a sink. A simple hardware link enables full-automatic processing. A programmable suspend voltage and a selectable output impedance protect the battery against unwanted transient currents during operating status.

    Battery-Evaluation
    Open Lightbox

    Battery-Evaluation

    Request information

    Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

    I want to receive information from Rohde & Schwarz via

    Marketing permission

    What does this mean in detail?

    I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

    Your rights

    This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

    Your request has been sent successfully. We will contact you shortly.
    An error is occurred, please try it again later.
    General and legal information

    Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

    Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

    1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

    2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

    3. Participation is free of charge and not dependent on the purchase of goods or services.

    4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

    5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

    Prize: 1x R&S®RTB2000 Digital Oscilloscope

    6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

    7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

    8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

    9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

    10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

    11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

    12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

    13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.