R&S®SZU100A IQ Upconverter

Key Facts

  • Upconversion of R&S®SMW200A generated signals to mmWave frequencies
  • Flat frequency response independent of set level and frequency
  • Fully characterized in factory; no need for external frequency response correction prior to measurements

Brief Description

The R&S®SZU100A I/Q upconverter extends the R&S®SMW200A vector signal generator into the mmWave range.

Specifications

Frequency Range 58.32 GHz to 64.80 GHz ± ½ occupied modulation bandwidth
RF modulation bandwidth 2GHz
Specified level range –80 dBm to +5 dBm (PEP)

Key Facts

  • Upconversion of R&S®SMW200A generated signals to mmWave frequencies
  • Flat frequency response independent of set level and frequency
  • Fully characterized in factory; no need for external frequency response correction prior to measurements
  • High spectral purity paired with high dynamic range
  • Seamless integration into the R&S®SMW200A operating concept for maximum usability

Brief Description

The R&S®SZU100A I/Q upconverter extends the R&S®SMW200A vector signal generator into the mmWave range. Its 2 GHz bandwidth, flat frequency response and dynamic range of over 80 dB allows the R&S®SZU100A to generate high-quality test signals in the frequency range from 57.32 GHz to 65.80 GHz for WLAN IEEE 802.11ad, 5G or microwave links as well as to test satellite and radar systems. Components, chips, transceivers, mobile devices and the communications infrastructure for these fields of application are conveniently tested using the R&S®SZU100A I/Q upconverter.

Specifications

Frequency
Range R&S®SZU-B1066 58.32 GHz to 64.80 GHz ± ½ occupied modulation bandwidth
Level
Setting range   –100 dBm to +15 dBm
Specified range   –80 dBm to +5 dBm (PEP),
–90 dBm to +10 dBm (PEP, typ.)
Level error level setting characteristic: auto, less than 5 degree temperature drift after internal adjustment < 2 dB
Interruption-free level setting range level setting characteristic: uninterrupted level setting > 10 dB (nominal)
Spectral purity
Harmonics   < –50 dBc
Nonharmonics   < –50 dBc
Subharmonics level > –40 dBm < –50 dBc
Wideband noise carrier offset > 30 MHz, measurement bandwidth = 1 Hz, CW, level = 10 dBm  
  PA switched on –146 dBm (1 Hz) (meas.)
  PA switched off thermal noise floor (approx. –174 dBm/Hz (meas.))
SSB phase noise with R&S®SMW-B22 option installed in the R&S®SMW200A I/Q, carrier offset = 20 kHz, measurement bandwidth = 1 Hz  
  f = 60.48 GHz < –98 dBc, –102 dBc (typ.)
I/Q modulation performance
RF modulation bandwidth fc = 58.32 GHz to 64.80 GHz 2 GHz
RF frequency response in specified RF modulation bandwidth   < 2.0 dB
Carrier leakage referenced to baseband full-scale input < –45 dBc
Suppression of image sideband for entire instrument in modulation band   > 30 dB, > 45 dB (nom.)
Two-tone IMD (2 carriers) PEP = 0 dBm up to 2000 MHz carrier spacing < –34 dBc (typ.)
EVM with BPSK, QPSK, 16QAM 60.48 GHz, WLAN IEEE 802.11ad signal, 1.76 GHz bandwid  
with R&S®SMW-B22 option installed in the R&S®SMW200A time domain power = 0 dBm  
  MCS 5 (BPSK) < –31 dB, < –34 dB (meas.)
  MCS 9 (QPSK) < –31 dB, < –34 dB (meas.)
  MCS 12 (16QAM) < –31 dB, < –34 dB (meas.)
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website