R&S®NGC100 Power supply series

A basic DC power supply from R&S®Essentials

R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 Power supply series
Open Lightbox
R&S®NGC100 power supply series, front low R&S®NGC100 power supply series, hero view R&S®NGC100 power supply series, back high R&S®NGC100 power supply series, hero view R&S®NGC100 power supply series, front high R&S®NGC100 power supply series, back low

Key facts

  • Max. output power: 100 W
  • Max. voltage per channel: 32 V
  • Max. current per channel: 3 A, 5 A or 10 A
  • Galvanically isolated, floating and short-circuit proof outputs
  • Intuitive, price-transparent online product configurator

Starting at USD 1,440

  • R&S®Essentials

Compact and easy to use

R&S®NGC100 DC power supplies are very energy efficient, remaining cool and quiet, even at maximum load. Practical interfaces and connectors make work quick and convenient while special applications have comfort functions. One, two, or three channels – a wide range of functions and fundamental specifications make R&S®NGC100 DC power supplies ideal for:
-Development labs
-Industrial environments
-Manufacturing
-Education
You can now use the new online configurator to quickly design your R&S®NGC100 DC power supply with full price transparency. Get your request processed in no time by the authorized distribution partner of your choice.

Features & benefits

Maximum output power at various operating points

With FlexPower

Get maximum power at various operating points. Unlike single-range power supplies, variable voltage and current combinations can be generated within an overall power limit.

Emulate real-world scenarios

With EasyArb 

Generate complex time varying output voltage or current sequences with the EasyArb function to emulate normal power subsystem behavior early in the design process or simulate power problems for DUT design verification. The EasyArb function lets you generate time varying output voltage and current sequences with dwell times down to 10 ms.

Log measurement values

Every millisecond

Logging data is vital to long-term monitoring, reviewing test setups and repeating test conditions to analyze power behavior or optimize power consumption. R&S®NGC100 power supplies simultaneously log voltage and current measurements over time on all outputs with a maximum acquisition rate of 1000 samples/s. Easily export the time stamped data as a CSV file for analysis, reports and documentation.

Higher current and voltage levels

With parallel and serial operation

Each output in the 2-channel and 3-channel models is completely isolated for maximum flexibility. Use the channels independently or combine them in series to increase the maximum voltage to 96 V, or in parallel for up to 10 A of current. The full galvanic isolation means that channels can be connected to supply balanced circuits without any need to think about grounding.

Up to 96 V with the R&S®NGC103 power supply
Open Lightbox

Up to 96 V with the R&S®NGC103 power supply

Control inrush current

With EasyRamp

Some test setups require a continuous rise in supply voltage instead of a rapid jump to control inrush currents. Increase output voltage continuously within 10 ms to 10 s with the EasyRamp function.

Create power up sequences

With output delay

Turn on each channel individually with a delay to meet requirements for modern micro controllers with multiple supply voltage levels and demand-specific power up sequences.

Compensate voltage drops

Using remote sensing

Improve voltage regulation and measurement accuracy with remote sensing. Regulate output voltage directly at the DUT input terminals instead of the power supply. The sense function compensates for voltage drops in supply leads, especially in applications with high current levels. R&S®NGC100 power supplies provide sense connections for each output.

Using remote sensing to compensate for load lead voltage drops
Open Lightbox

Using remote sensing to compensate for load lead voltage drops

Start instrument functions

With an external trigger

An external trigger signal (TTL) to the voltage interface on the back panel of the instrument can start an arbitrary function, activate and deactivate output delays or activate data logging.
 

Direct control of output voltage

With the analog control interface

Directly and quickly control output voltage. External analog voltage from 0 V to 10 V or current from 4 mA to 20 mA can control any or all outputs with input scaling of 0 to 100%. Galvanic isolation between the control voltage and the outputs simplifies connections while maintaining user safety even in floating circuit applications.

Available models

Available models
Models
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at

R&S®NGC101

Order number 3657.2288.02

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Starting at
USD 1,440

R&S®NGC101-G

Order number 3657.2288.03

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Starting at
USD 1,990

R&S®NGC102

Order number 3657.2359.02

Number of output channels
2
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
5 A
Starting at
USD 1,620

R&S®NGC102-G

Order number 3657.2359.03

Number of output channels
2
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
5 A
Starting at
USD 2,160

R&S®NGC103

Order number 3657.2413.02

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
3 A
Starting at
USD 1,790

R&S®NGC103-G

Order number 3657.2413.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
3 A
Starting at
USD 2,340
Specifications
Electrical specifications
Number of output channels 1 / 2 / 3
Total output power max. 100 W
Maximum output power per channel 100 W/50 W/33 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 10 A/5 A/3 A
Voltage ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1 mV (RMS)
R&S®NGC102/103: < 450 µV (RMS)
Current ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1.5 mA (RMS) (meas.)
R&S®NGC102/103: < 1 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 1 ms (meas.)
Programming resolution voltage 1 mV
Programming resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
≥ 1 A: 1 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
 ≥ 1 A: 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 2 mV
Readback accuracy current ±(% of output + offset) typ. < 0.05 % + 4 mA (R&S®NGC101: typ. < 0.15 % + 10 mA)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode -
Output sequencing
External trigger
Arbitrary function ● (EasyArb)
Analog/modulation interface
Data logging
Display and interfaces
Display 3.5" QVGA
Rear panel connections Connector block with 4 lines per channel
Remote control interfaces: standard USB, LAN; R&S®NGC100-G models with IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 222 mm × 97 mm × 291 mm
Weight 2.6 kg
Rack installation R&S®HZC95 option

Available options

Rack adapter
Product
Description
R&S®HZC95

Order number 5800.2054.02

Description

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.