R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front high R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view

Key facts

  • Frequency range from 18 GHz to 90 GHz
  • Extremely fast RX list mode
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay as well as automotive radar
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements

Designed for extremely accurate over-the-air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individually scalable OTA power measurement solution for benchtop applications or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz, it is perfect for over-the-air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of transmit antenna output power.

Features & benefits

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain, antenna patterns and mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, antenna pattern and diode detector are calibrated together. The user does not need to make any complicated system calibrations.

OTA power measurement system
Open Lightbox

OTA power measurement system

Low-reflection antenna module

Low radar cross section avoids disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideal for screened environments, due to the virtual absence of reflections.

R&S®NRPM-A90 low-reflection antenna module
Open Lightbox

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

The R&S®NRPM OTA power measurement solution uses a highly sensitive diode detector integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules can measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be precisely determined.

OTA power measurement solution, benchtop
Open Lightbox

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the DUT receiver, it is necessary to know the exact OTA transmitted power at the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT for the transmit power calibration of the signal generator. The calibration uses an R&S®NRPM-A90/A90D antenna module, which is later replaced with the DUT. The receive power of the DUT is precisely detected.

System calibration for OTA receiver tests
Open Lightbox

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power for all the antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane properly functions. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged on at least two horizontal planes.

TX beamforming verification
Open Lightbox

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty (measurement distance 1 m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Product
Description
R&S®NRPM-A90

Order number 1426.7760.02

Description

Single-polarized antenna module

Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power
measurements.

R&S®NRPM-A90D

Order number 1426.7777.02

Description

Dual-polarized antenna module

Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.

Sensor modules
Product
Description
R&S®NRPM3

Order number 1425.8563.02

Description

Three-channel sensor module

R&S®NRPM3N

Order number 1425.8592.02

Description

Three Channel LAN Sensor Module

Interface for shielded RF test box
Product
Description
R&S®NRPM-ZD3

Order number 1425.8786.02

Description

Filtered cable feedthrough

R&S®NRPM-ZKD3

Order number 1436.2984.02

Description

Interface cable

Interface for benchtop application
Product
Description
R&S®NRPM-Z3

Order number 1426.7602.02

Description

Interface module

The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.

General accessories
Product
Description
R&S®NRP-ZKU

Order number 1419.0658.02

Description

USB-A interface cable, length: 0.75 m

R&S®NRP-ZKU

Order number 1419.0658.03

Description

USB-A interface cable, length: 1.5 m

R&S®NRP-ZKU

Order number 1419.0658.04

Description

USB-A interface cable, length: 3 m

R&S®NRP-ZKU

Order number 1419.0658.05

Description

USB-A interface cable, length: 5 m

R&S®NRP-ZK6

Order number 1419.0664.02

Description

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Order number 1419.0664.03

Description

6-pole interface cable, length: 3 m

R&S®NRP-ZK6

Order number 1419.0664.04

Description

6-pole interface cable, length: 5 m

R&S®NRP-Z5

Order number 1146.7740.02

Description

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

R&S®NRPM-ZKT

Order number 1425.8857.02

Description

Trigger cable

Documentation
Product
Description
R&S®DCV-1

Order number 0240.2187.06

Description

Documentation of calibration values

R&S®DCV-ZP

Order number 1173.6506.02

Description

Printout of DCV

Related videos

Understanding OTA Power Measurements

This video provides a brief technical introduction to over-the-air (OTA) power measurements, how they are different from traditional conducted power measurements.

18-May-2020

Using the R&S®NRPM

This short video provides an brief introduction to the R&S®NRPM over-the-air (OTA) power measurement system.

18-May-2020

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. Draw Period. This Draw begins January 01, 2020 to December 31, 2020. R&S reserves the right to change the end date of the Draw.

3. Participation. No purchase necessary. This Draw is limited to legal residents of the United States and Canada, age of 18 years or older, at the time of the submission. Employees of R&S, its affiliates, subsidiaries, distribution partners and agents, and immediate family members of each, are not eligible. Government agencies and institutions (including public universities), and their employees are not eligible to participate or receive prizes. This Draw is void where prohibited by law.

4. Entrance. Fill out the form above during the Draw Period and follow the instructions to complete and submit the form. Limit one entry per person. R&S, in its sole, reasonable discretion, reserves the right to disqualify any entries by persons determined to be tampering with or abusing any aspect of this Draw. An entrant must provide their name, address, and email address to be considered eligible.

5. Data Protection and Privacy Policy. An entrant must provide personal data such as name, address and email address to be considered eligible. This data will be used to make the necessary contact information available for purposes of notifying the winner. In addition to notification purposes, the data collected will be used for marketing purposes and the entrant agrees to allow R&S to contact them. The personal data that has been received from you and saved will not be sold by Rohde & Schwarz to third parties. It may, however, be necessary to disclose your personal data to Rohde & Schwarz service providers for business purposes, so that they can provide services for Rohde & Schwarz. The Rohde & Schwarz websites may contain links to other websites. This statement of privacy does not cover these other websites and Rohde & Schwarz cannot assume any responsibility whatsoever, neither for the privacy practices nor the content of these other websites. Further information regarding data protection and privacy can be found at: http://www.rohde-schwarz.us/en/general_information/statement-of-rivacy_101515.html.

6. Prize Description. There will be one (1) winner for each of one (1) of ten (10) R&S®RTB2000 Digital Oscilloscopes. R&S reserves the right to substitute a prize of equal or greater value in the event that the stated prize becomes unavailable. No cash equivalent or exchange is permitted. All federal, state and/or local income and other taxes or duties, if any, are the winner's sole responsibility.

7. Odds of Winning. The odds of winning this Draw depend on the number of eligible entries received.

8. Winners Selection. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich.

9. Winner Notification. The winners of each of the prizes will be informed by e-mail within five (5) working days. The participant that is selected as winner of the prize shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

10. Limitation of Liability. By entering, entrants release and hold harmless Rohde & Schwarz and its respective parents, subsidiaries, affiliates, directors, officers, employees and agents from any and all liability or any injuries, loss, or damage of any kind arising from or in connection with this Draw or with any prize awarded. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

11. Internet. If for any reason the Internet portion of the Draw is not capable of running as planned, including infection by computer virus, bugs, tampering, unauthorized intervention, fraud, technical failures, or any other causes beyond the control of R&S or its third-party providers that corrupt or affect the administration, security, fairness, integrity or proper conduct of this Draw, R&S reserves the right, at its sole discretion, to cancel, terminate, modify, or suspend the Draw, and to disqualify any individual who tampers with the entry process.

R&S assumes no responsibility for any error, omission, interruption, deletion, defect, delay in operation or transmission, communications-line failure, theft, or destruction or unauthorized access to, or alteration of, entries. R&S is not responsible for any problems or technical malfunction of any telephone network or lines, computer online systems, servers or providers, computer equipment, or software, or for failure of any email or entry to be received by Rohde & Schwarz on account of technical problems or traffic congestion on the Internet or at any Web site, or any combination thereof, including any injury or damage to participant's or any other person's computer related to or resulting from participation or downloading any materials in this Draw.

12. General Conditions.

a. Entrants agree to abide by the terms of these official rules and by the decisions of R&S, which are final and binding on all matters pertaining to this Draw. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Draw. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Draw.

b. Income Taxes: A U.S. winner will need to supply to R&S their Social Security Number for a 1099 for the total value (Current estimate is approximately $1,540) to be issued. Any winner is solely responsible for any and all tax liability/responsibility for this. R&S is not responsible for any taxes or tax implications to or of the winner associated with Draw winnings.

13. Winner Information. For the names of the winners, send a self-addressed stamped envelope to Rohde & Schwarz USA, Inc. at 6821 Benjamin Franklin Drive, Columbia, MD 21046.

ATTN: Winner – Rohde & Schwarz’ 10 years Rohde & Schwarz oscilloscopes Draw. Requests received after January 1, 2021, will not be fulfilled.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.