Key facts

  • MIPI RFFE (version 1.X, 2.0, 2.1, 3.0) and MIPI SPMI 
  • Fully integrated in the GUI for quick setups
  • Hardware implementation for reliable triggering on events, such as start, stop, label, data and various error conditions
  • Label list support
  • Display all decoded telegrams in a table
  • Multi-domain icon

Oscilloscope software

The R&S®RTO and R&S®RTP oscilloscopes support triggering and decoding of the MIPI-RFFE protocol. The MXO series support MIPI SPMI decoding. You can set up decoding in seconds. For detailed analysis, results can be viewed as color-coded telegrams and/or in a table. Errors are identified reliably and efficiently with the hardware-accelerated trigger. You can trigger on start, stop, label and data and various error conditions.

Features & benefits

Fast bus setup

Set up the bus in seconds from the app cockpit

From the app cockpit, any protocol can be configured in only a few steps. Once the bus to be decoded has been chosen, the connected channels selected and the correct levels set, decoding begins automatically.

Open Lightbox

Fast and easy configuration of MIPI-RFFE and SPMI decoding.

Color-coded protocol details

Protocol display as color-coded bus signals and in the decode table

You can analyze the decoded bus frames by overlaying the signal with color-coded data. Address and data content can be displayed in hex, bin and ASCII format. The flexible screen setup always gives you an excellent overview. Protocol details can also be displayed in a concise table. Select the data format and decode layer that best fits your needs.

Open Lightbox

Decoding details of MIPI RFFE and SPMI protocol displayed in the waveform and result table – select the data format and decoding layer.

Powerful trigger capabilities

Trigger on start, stop, label and data and various error conditions.

The protocol-specific trigger lets you reliably isolate protocol events and errors. High acquisition rates make Rohde & Schwarz oscilloscopes ideal for finding errors quickly. Protocol-specific trigger results can then be decoded. Hardware-based triggering can be performed on specific protocol content, e.g. addresses, data and protocol errors.

Open Lightbox

Focus triggering on protocol details of interest – select from a comprehensive list of MIPI RFFE protocol elements and configure parameters.

Powerful search and navigation capabilities

Search and navigate in recorded acquisitions

Comprehensive search functions simplify the analysis of long signal sequences. Search for waveforms based on various criteria, such as signal faults and protocol content. All detected events are shown in a table with timestamps. The individual events can be examined in a zoom window with simple navigation between events.

Open Lightbox

Benefit from powerful search capabilities to analyze long recordings.

Available models

Available models
Models
Serial standard
Label support
Search

R&S®RTP-K550

Order number 1803.6678.02

Serial standard
MIPI RFFE
Label support
Search

R&S®RTO6-K550

Order number 1801.7054.02

Serial standard
MIPI RFFE
Label support
Search

R&S®MXO4-K550

Order number 1335.5214.02

Serial standard
MIPI SPMI
Label support
Search

R&S®MXO5C-K550

Order number 1803.1447.02

Serial standard
MIPI SPMI
Label support
Search

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.