Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
96 Results
The test case wizard enables the signal generator to set up all required parameters for conformance testing of 5G NR base stations in no time with just a few clicks.
25-May-2021
Synthetic aperture radar (SAR) uses radar wavelengths for airborne or spaceborne ground mapping. The resolution of the SAR ground map depends on the range and cross-range SAR processing resolution. Cross-range resolution is determined by integrating pulses along a flight path for a period of time to create a synthetic aperture. Longer synthetic apertures result in finer cross-range resolution. Range resolution is achieved by radar waveform bandwidth in the form of a linear frequency modulated (LFM) chirp. Wider bandwidth enables finer range resolution.
16-Apr-2021
Analyzing high speed datacom interfaces is an important task and ensures signal integrity. One major challenge of this analysis is the connection between the physical interface and the oscilloscope, as most of the datacom interfaces do not provide test connections suitable for RF. A test fixture is required as a bridge between the high speed datacom IF and the RF connector of the oscilloscope, but this will affect the signal integrity measurement. The R&S®RTP and R&S®RTO2000 oscilloscopes with the advanced jitter option can analyze and separate jitter contributions. Additionally, the option can evaluate the impact of test fixtures and traces inherently and give the user a good understanding of the impact of their test setup.
31-Mar-2021
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
Source measure units R&S®NGU401 and R&S®NGU201 are capable of precise current measurements from sub-microampere up to ampere. This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep. Subsequently the application program determines the voltage and current value for each sweep step and plots the results in an I-V curve .The tool can be utilized to characterize all kinds of two-pole devices like diodes, LEDs and solar panels.This application note can also be used in connection with DC power supplies R&S®NGM201 and R&S®NGM202.
15-Feb-2021 | AN-No. 1GP129
Performing precompliance measurements on power supplies requires using a line impedance stabilization network (LISN) for results that can be compared to limit values. While LISNs are standard in any precompliance lab, often no LISN is available for early R&D testing. If high accuracy is not your goal and you just need a simple tool for debugging, you can build your own LISN. Rohde & Schwarz oscilloscopes with powerful FFT analysis, are ideal for optimizing EMI filters or debugging unwanted emissions during development.
14-Jan-2021
In this day and age of internet of things, more and more devices are connected to the local network, making it even more difficult for the IT department to monitor them. Rohde & Schwarz instruments are also increasingly accessed via their LAN interface, which provides additional convenience features such as remote desktop, SMB file transfer or a web interface. To make it easier to monitor the use and status of instruments, some devices offer a software option, the Health and Utilization Monitoring Service (HUMS).HUMS can be accessed via SNMP and REST (HTTP) and provides all necessary information about the health status and utilization over time in many details.This application note describes how to access HUMS and what data is provided.
11-Jan-2021 | AN-No. GFM336
High-precision two-quadrant power supplies generate current profiles and simulate batteries
10-Dec-2020
Verify and optimize your product design under realistic fading conditions in a deterministic lab environment that allows repeatable measurements using standardized and user-defined fading profiles.
27-Oct-2020
Many serial interfaces use Manchester or non-return-to-zero (NRZ) coding. Oscilloscopes typically offer dedicated software options for debugging and testing the communications interfaces for common standards such as I2C, UART or CAN. The R&S®RTx-K50 option expands the addressable range of interface standards by adding decoding capability for standardized and proprietary Manchester or NRZ coded buses. It allows customizable configuration of the protocol structure that has to be decoded.
19-Oct-2020
Timing components such as low jitter oscillators and clocks are necessary to facilitate increasing data rates in high speed digital designs. As part of the overall system design, the components also have to perform in the system’s non-ideal power integrity environment and limit the power supply induced phase noise and jitter from power rail disturbances. Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Load pull is a powerful method for characterizing RF power amplifiers through impedance variation. Load pull enables model extraction and validation as well as performance, ruggedness and efficiency testing.
02-Sep-2020
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
Testing radar warning equipment in realistic scenarios is crucial to reliable field performance. This typically involved dedicated instruments or test systems. Commercial vector signal generators (VSG) such as the R&S®SMW200A from Rohde & Schwarz have become a very attractive alternative thanks to their increased available bandwidth and processing power.
13-Aug-2020
Make more accurate power rail measurements.
09-Jul-2020
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery simulators. Testing battery management systems with Rohde & Schwarz power supplies NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery
08-Jun-2020
More frequency bands and larger dynamic ranges increase the number of test points required in characterization and production of the latest RF frontends (RFFE). Actively managing test time and cost while maintaining quality is more important than ever before.
08-Jun-2020
Since June 2017 almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 345 defines the tests to be performed on broadcast sound receivers, and the requirements to be passed.This application note describes the test procedures and provides script files and interferer signals for the Broadcast Test Center R&S®BTC.
29-May-2020 | AN-No. 1GP117
10BASE-T1S Ethernet enables the integration of diverse sensors into an automotive-Ethernet vehicle supply system, for example short-range radar sensors for detecting blind spots or ultrasonic sensors for the parking assistant. For reliable operation of the functions, data transmission over 10BASE‑T1S Ethernet must be assured at all times and in every climatic environment. Functionality must be tested during development and in production. Only 10BASE-T1S Ethernet interfaces that have passed compliance testing in line with IEEE 802.3cg can be deployed in vehicles. Consequently, vehicle manufacturers and their suppliers need measuring equipment that allows them to perform these tests quickly and reliably.
15-May-2020
Oscilloscopes are basic everyday instruments for engineers and electricians. Maintenance tasks, however, sometimes require very specific measurements that are not available as standard functionality or are difficult to set up manually. With the R&S®RTH-K38 user scripting option, engineers can now design their own measurement function and a simple user interface. This paper describes how to use this unique feature for railway maintenance work.
06-May-2020
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO signals (e.g. 5G NR, WLAN), multi-antenna radar signals and differential high-speed digital signals (e.g. USB 3.x). These applications require the oscilloscope channels to be tightly aligned. This means the channel-to-channel residual skew has to be measured accurately so that it can be compensated. The channel-to-channel phase mismatch is reduced to a minimum, which plays a crucial role in achieving reliable measurement results.
06-May-2020
With the R&S®Pulse Sequencer radar simulation software, users can easily and intuitively create scenarios for simulation of angle of arrival (AoA). Together with multiple coupled R&S®SMW200A vector signal generators, this solution allows quick and thorough performance characterization of all types of direction finding equipment such as devices that use amplitude comparison, interferometric or time difference of arrival (TDOA) techniques. This document describes our test solution for testing devices that use amplitude comparison techniques.
02-Apr-2020
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
Over the past few years, electronics developers have developed a variety of approaches to avoid interference on high-speed signals on printed circuit boards. However, with increasing complexity and frequency, PCBs set new limits, supporting frequencies of 40 GHz and higher. Driven by the fast growing 5G market, today’s digital systems operate in these high frequency ranges that come with completely new challenges. With slope steepness’s of just a few picoseconds, any discontinuity in the impedance and impairment of the inductance or capacitance on the PCB or back drill defects on the PCB can have a massive impact on the signal quality. The industry recognizes that there is a growing need for functional high-speed testing of PCBs. The MicroCraft® E2V6151 series combined with an R&S®ZNB vector signal analyzer delivers a fully automated solution.
25-Mar-2020
Fault identification in single elements of antenna arrays by scanning in near-field range and applying the near-field to far-field transformation method.
24-Mar-2020
With its small footprint, the R&S®ATS1000 antenna test system is the ideal direct far-field OTA system to test phased array antennas. The system tests and optimizes the radiation characteristics of any modules using the AiP technology from 18 GHz to 87 GHz.
12-Mar-2020
Well-matched RF ports are a crucial aspect to any RF system. Matched ports, for example, protect amplifier output ports from reflected power overload. This undesired reflected power could destroy the whole amplifier. Matched ports also maximize power transmission, effectively extending the battery life of wireless products such as those made for the internet of things (IoT).
05-Mar-2020