Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
10647 Results
High-speed serial interfaces often transmit data with differential signaling and differential probes can be used to access signal traces. In addition to differential inputs, these probes have a ground connection.
02-Nov-2022
Optimizing electric drivetrains with MXO oscilloscopes
12-Mar-2024
Measurement the inherent noise of a TV Receiver/Demodulator
20-Jul-2001 | AN-No. 7BM11
Remote Operation of R&S Instruments Using Remote Desktop Connection via LAN
05-Jul-2007 | AN-No. RAC-0703-0029
Operating Guide for WCDMA Test Setup according to 3GPP TS34.121
15-Apr-2009 | AN-No. 1CM71
Monitoring on up to 10 000 channels with different parameter settings
13-Jul-2012
Test of DVB-H Capable Mobile Phones in Development and Production
07-Apr-2005 | AN-No. 1MA91
LTE beamforming can be accurately tested with one or more R&S®RTO digital oscilloscopes for a 1×2, 1×4 or even a 1×8 MIMO system.
08-Aug-2024
In this paper we will review the basics of spurious measurements and how the parameters used can affect the detection performance.
14-Jul-2017 | AN-No. 1EF97
The super-resolution DF method determines bearings of multiple emissions on the same frequency.
04-Mar-2016
For measurement settings below 10 mV/div, oscilloscopes typically reduce the measurement bandwidth in order to keep the trace noise as low as possible. The R&S®RTO is different: It offers the full bandwidth even for the most sensitive settings, and an A/D converter with more than 7 effective bits (ENOB) digitizes the signal.
13-Jul-2012
Remote Emulation with the R&S SMA100B Signal Generator
11-Dec-2019 | AN-No. 1GP120
Three-port on-wafer mixer measurements up to the THz range on MPI probe stations
14-Aug-2025
Solutions and Tipps for NR FR1 in TDD Downlink Mode
5G New Radio (NR) is a radio technology specified by 3GPP and was first released in 3GPP release 15. It is designed to target three use cases, i.e. enhanced mobile broadband (eMBB), massive machine type communication (mMTC) and ultra-reliable low latency communication (URLLC). Among these three use cases, eMBB represents actually a further evolution of mobile broadband communication from LTE standard. According to the technical performance requirement defined by IMT-2020, by deploying 5G technology, peak data rates of eMBB application are expected to reach 20 Gbps in downlink (DL) and 10 Gbps in uplink (UL) direction, respectively. Typical use cases of eMBB are data hungry applications, such as high resolution 8K video streaming, virtual reality (VR), augmented reality (AR) etc.Verification of a 5G capable user equipment (UE) with respect to its achievable maximum data throughput under controllable and deterministic test conditions is an essential process during the design phase of the product. Performance centric verification through identification of the data throughput bottleneck, product benchmarking against a golden device enhances tremendously the user experience in the end.This document focuses on 5G NR frequency range 1 (FR1) with TDD duplex mode in E-UTRAN New-radio Dual Connectivity (ENDC) operating mode. As 5G NR physical layer offers a plethora of flexibility, the motivation here is to provide a kind of guideline of relevant parameter settings to stimulate device under test (DUT)'s max throughput capacity. The status quo of the R&S solutions at the time when the application note is created are described. Shown feature sets are constantly evolving, so the screenshots used and the parameters shown may change.
07-Jul-2022 | AN-No. 1SL379
The R&S®SMW-K501 and R&S®SMW-K502 options from Rohde & Schwarz enable engineers to quickly model complex pulse scenarios.
06-Jun-2017
In this application note the fundamental working principles of active antennas and the differences compared to passive antennas are asserted.
03-Feb-2016 | AN-No. 8GE02
Crime scene investigation with cellular network analysis
14-Mar-2024
The R&S®RTx-K50 option expands the addressable range of interface standards by adding decoding capability for standardized and proprietary Manchester or NRZ coded buses.
19-Oct-2020
EU Declaration of Conformity for Power Meter NPA101 Power Analyzer: NPA501, NPA501-G Compliance Tester: NPA701, NPA701-G
Product safety certificate according to CAN/CSA/UL standards for OSP220, OSP230 and OSP320
Product safety certificate according to CAN/CSA/UL standards for NGL201, NGL202, NGM201, NGM202, NGU201, NGU401 and NGU411
Product safety certificate according to EN/IEC standards for OSP220, OSP230 and OSP320
Product safety certificate according to CAN/CSA/UL standards for AREG800A
Product safety certificate according to EN/IEC standards for SMB100B, SMBV100B and AREG100A