Question
We use the receiver mode. After sending the command “CALC:UNIT:POW DBUV” we get the error “-200,"Execution error; Function not available” back. That command is mentioned in the manual and the “unit” dBuV” should be available. What is wrong?
We use the receiver mode. After sending the command “CALC:UNIT:POW DBUV” we get the error “-200,"Execution error; Function not available” back. That command is mentioned in the manual and the “unit” dBuV” should be available. What is wrong?
You are right - in receiver mode it must be possible to use dBuV. In fact, that is the default setting after a preset.
Please check if there is any other transducer activated for another unit i.e. dBuV/m. After deactivation of that transducer the command is accepted.