R&S®NGL200 power supply series, front viewR&S®NGL200 power supply series, front lowR&S®NGL200 power supply series, 3DR&S®NGL200 power supply series, back viewR&S®NGL200 power supply series, front viewR&S®NGL200 power supply series, front lowR&S®NGL200 power supply series, 3DR&S®NGL200 power supply series, back viewR&S®NGL200 power supply series

Key Facts

  • Max. output power: 120 W
  • Voltage per channel: 0 V to 20 V
  • Max. current per channel: 6 A
  • Load recovery time: < 30 µs
  • Intuitive, price-transparent online product configurator
  • Promo DC power supplies

High precision source and sink

Due to high accuracy and fast load recovery time, the R&S®NGL200 DC power supply series is perfect for challenging applications, such as:
- battery tests
- power consumption test
- simulation of voltage drops 
- supplying sensitive designs
Their two-quadrant architecture allows R&S®NGL200 to function both as a source and a sink to simulate batteries and loads. Their short recovery times enable these DC power supplies to handle fast load changes that occur for example when mobile communications devices switch from sleep mode to transmit mode. 
Choosing the R&S®NGL200 has never been easier: with our new online configurator you can choose the DC power supply and options you need with full price transparency. Send a purchase request directly to the authorized Rohde & Schwarz distribution partner of your choice. Discover it for yourself, click 'configure and quote'.

Features & benefits

Optimized load recovery time

Consumer electronics such as mobile phones and IoT devices require very little current in sleep mode. However, the current requirement increases abruptly as soon as they switch to transmit mode. A power supply used to power such DUTs must be capable of handling current increases from a few µA to the ampere range without creating voltage drops or overshoots. Thanks to their fast load recovery time of < 30 µs even during a challenging load change, the R&S®NGL200 power supplies are ideal for powering IoT and other battery-operated devices.

Exceptionally fast load recovery time
Abrir o Lightbox

Exceptionally fast load recovery time

Power supplies usually respond to abrupt load changes with overshoot and slow recovery times. Thanks to specially optimized control circuits, the R&S®NGL200 power supplies achieve recovery times of < 30 µs.

6 ½ digit resolution

With a resolution of up to 6½ digits when measuring voltage, current and power, the R&S®NGL200 power supply series is perfect for characterizing devices with low standby power consumption and high current in full load operation. The entire measuring range is covered without having to switch ranges. This results in faster measurements. In many cases, an additional digital multimeter is no longer necessary.

6 ½ digit resolution in V/I metering
Abrir o Lightbox

6 ½ digit resolution in V/I metering

The measured currents and voltages are displayed with 6 ½ digit resolution.

Minimal ripple and noise

Advanced electronic circuitry is often very complex and sensitive to interference on the supply lines. In order to supply interference-free voltage to such sensitive DUTs, the power supplies must provide extremely stable output voltages and currents. All types of ripple and noise need to be avoided. The R&S®NGL200 power supplies have linear regulation and are ideal for sensitive DUTs.

Two-quadrant operation

The two-quadrant architecture of the R&S®NGL200 power supplies allows them to function both as a source and a sink and simulate batteries or loads. The power supply automatically switches from source to sink mode. As soon as the externally applied voltage exceeds the set nominal voltage, current flows into the power supply. This is indicated by a negative current reading.

Source and sink operation
Abrir o Lightbox

Source and sink operation

The R&S®NGL200 power supplies automatically switch from supply mode to load mode. Here, channel 2 is operating as a load. This is indicated by a negative current reading.

Easy to use, price transparent configurator

We are striving to provide our customers with the possibility to choose the right T&M instrument quickly, easily, and with full price transparency. The R&S®NGL200 and other instruments from the R&S Essentials portfolio can now be configured online, providing you with the following benefits:
- user-friendly and easy to navigate configurator
- full cost transparency at every step of configuration
- fast order processing through authorized distribution partners 
- next-day delivery from selected partners

Available models

Available models
Modelos
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Começando em

R&S®NGL201

Order Number 3638.3376.02

Number of output channels
1
Max. output power
60 W
Output voltage per channel
0 V to 20 V
Output current per channel
≤ 6 V: 0 A to 6 A
> 6 V: 0 A to 3 A
Começando em
Consultar preço

R&S®NGL202

Order Number 3638.3376.03

Number of output channels
2
Max. output power
120 W
Output voltage per channel
0 V to 20 V
Output current per channel
≤ 6 V: 0 A to 6 A
> 6 V: 0 A to 3 A
Começando em
Consultar preço
Specifications
Electrical specifications
Number of output channels1/2
Total output powermax. 60 W/120 W
Maximum output power per channel60 W
Output voltage per channel0 V to 20 V
Maximum output current per channel≤ 6 V: 6 A
> 6 V: 3 A
Voltage ripple and noise  (20 Hz to 20 MHz)< 500 µV (RMS)
< 2 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz)< 1 mA (RMS) (meas.)
Load recovery time  (10 % to 90 % load change within a band of ± 20 mV of set voltage)< 30 µs
Programming resolution voltage1 mV
Programming resolution current0.1 mA
Output measurements
Readback resolution voltage10 µV
Readback resolution current10 µA
Readback accuracy voltage ±(% of output + offset)< 0.02 % + 2 mV
Readback accuracy current ±(% of output + offset)< 0.05 % + 250 µA
Special functions
Measurement functionsvoltage, current, power, energy
Protection functionsOVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode
Output sequencing
Trigger input/output
Arbitrary function● (QuickArb)
Analog/modulation interface-
Data logging● (Standard)
Display and interfaces
DisplayTFT 5' 800 pixel x 480 pixel WVGA touch
Rear panel connectionsconnector block with 4 lines per channel
Remote control interfaces: standardUSB, LAN
Remote control interfaces: optionalWireless LAN, IEEE-488 (GPIB)
General data
Dimensions (W × H × D)222 mm × 97 mm × 436 mm
Weight7.1 kg/7.3 kg
Rack installationR&S®HZN96 option

Available options

General
Product
Descrição
R&S®NGL-B105

Order Number 3652.6356.02

Descrição

IEEE-488 (GPIB) Interface

General
Product
Descrição
R&S®NGL-K102

Order Number 3652.6362.02

Descrição

Wireless LAN remote control

R&S®NGL-K103

Order Number 3652.6385.02

Descrição

Digital trigger I/O

General accessories
Product
Descrição
R&S®HZN96

Order Number 3638.7813.02

Descrição

19"" rack adapter, 2HU

Vídeos relacionados

Medição de V/I com resolução de 6,5 dígitos

dez 12, 2018

Tempo de recuperação de carga otimizado com sobretensão mínima

dez 12, 2018

Interface de usuário intuitiva

dez 12, 2018

Promoção de fontes de alimentação CC

Promoção de fontes de alimentação CC e analisadores de potência

Economize mais de 20% em analisadores de potência totalmente equipados, fontes de alimentação CC e medidores de potência da Rohde & Schwarz.

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Quero receber informações da Rohde & Schwarz por

Licença de marketing

O que isso significa?

Concordo que a ROHDE & SCHWARZ GmbH & Co. KG e a entidade ou subsidiária ROHDE & SCHWARZ que figuram na Informação Legal deste site podem entrar em contato comigo por meio do canal escolhido (e-mail ou correio) para fins de marketing e publicidade (por exemplo, informações sobre ofertas especiais e promoções de descontos) relacionados, mas não limitados, a produtos e soluções para teste e medição, comunicações seguras, monitoramento e testes de redes, broadcast e mídia, e segurança cibernética.

Seus direitos

Esta declaração de consentimento pode ser retirada a qualquer momento, enviando um e-mail com o assunto "Cancelar subscrição" para news@rohde-schwarz.com. Além disso, cada e-mail enviado tem um link para cancelar a subscrição de futuros anúncios por e-mail. Mais detalhes sobre a utilização de dados pessoais e o procedimento de rescisão estão definidos na “Declaração de privacidade”.

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.