R&S®NGE100B Power supply series

A basic power supply from R&S Essentials

R&S®NGE100B Power supply series
Open Lightbox
R&S®NGE100B Power supply series
Open Lightbox
R&S®NGE100B Power supply series
Open Lightbox
R&S®NGE100B Power supply series
Open Lightbox
R&S®NGE100B Power supply series
Open Lightbox
R&S®NGE103B power supply, front view R&S®NGE102B power supply, front view R&S®NGE103B power supply, rear view R&S®NGE100B power supply series, side view R&S®NGE100B power supply series, hero view

Key Facts

  • The R&S®NGE102B with two or the R&S®NGE103B with three individual channels
  • Max. output power of 66 W with the R&S®NGE102B, 100 W with the R&S®NGE103B
  • Max. output voltage of 32 V per channel
  • USB interface (VCP/TMC), optional LAN (LXI), optional digital I/O (4bit)
  • Intuitive, price-transparent online product configurator

Reduced to the max

The R&S®NGE100B DC power supply series consists of robust, high-performance, affordable instruments. They combine high efficiency with low ripple and a variety of comfort functions not usually found in this class of DC power supply.
The R&S®NGE100B is ideal for:
-R&D;
-Education
-Manufacturing tests
-Maintenance and repair
You can now easily configure the R&S®NGE100B DC power supply online. Benefit from full price transparency, the user-friendly configurator and fast purchase request processing with the authorized distribution partner of your choice. Click "Configure and quote" to start configuration. 

Caractéristiques & avantages

All channels galvanically isolated and earth free

The circuitry in each channel is completely separated from the others with no connection to chassis ground. This makes combining the channels to drive bipolar circuitries that might need +12 V/–12 V easy and eliminates any ground problems in a complex DUT.

Driving a bipolar circuit
Open Lightbox

Driving a bipolar circuit

Combine channels to drive bipolar circuitry in complex DUTs that might need +12 V and –12 V without ground problems.

Parallel and serial operation

Because all channels are electrically equivalent, they can be combined in serial mode for higher voltages. Up to 96 V are possible with the R&S®NGE103B, up to 64 V with the R&S®NGE102B. Channels can be bundled for higher current in parallel mode. Up to 6 A are possible when two channels are combined. Using all three of the R&S®NGE103B channels, even 9 A is possible.

Parallel and serial operation
Open Lightbox

Parallel and serial operation

The output channels can be combined in serial or parallel for higher voltages or currents.

Protection functions

For each channel, users can separately set:

  • Maximum current (electronic fuse, overcurrent protection, OCP)
  • Maximum voltage (overvoltage protection, OVP)
  • Maximum power (overpower protection, OPP)
When a limit is reached, the output channel will automatically switch off and a message displayed. The overcurrent protection can be linked to other channels (FuseLink function). Here, the channel that exceeds the maximum current level and all linked channels are switched off.

Protection functions
Open Lightbox

Protection functions

If a limit is reached, the output channel will automatically switch off and a message will be displayed.

Color-coded operating conditions

All operating conditions are shown clearly on the 3.5" QVGA display (320 × 240 pixel), including the output power and the status of any protective functions. Colors indicate different operating conditions:

  • Active output is green when working in constant voltage mode and red when working in constant current mode
  • Inactive output is white. Whenever a channel is in setting mode, the number being set has a blue background.

The operating conditions are marked by colors
Open Lightbox

The operating conditions are marked by colors

Constant voltage is green, constant current red, inactive channels are white and a blue background indicates a channel in setting mode.

Connectivity

  • Front connectors with 4 mm safety binding posts
  • USB interface (virtual COM port and TMC class)
  • LAN interface (LXI) with integrated web server (R&S®NGE-K101 option) 
  • Wireless LAN, unique in class (R&S®NGE-K102 option)
  • Digital trigger in/out (4-bit) on the rear (R&S®NGE-K103 option)

Digital I/O
Open Lightbox

Digital I/O

Channel 1 of the optional digital I/O interface is used as a trigger input.

Easy to use, price transparent configurator

We help customers choose the right T&M instrument quickly, easily and with full price transparency. The R&S®NGP800 and other instruments from the R&S Essentials portfolio can now be configured online for the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every step of configuration
- Fast order processing through authorized distribution partners 
- Next-day delivery from selected partners

Available models

Available models
Modèles
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Commençant à

R&S®NGE102B

Numéro de commande 5601.3800.02

Number of output channels
2
Max. output power
66 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Commençant à
Prix sur demande

R&S®NGE103B

Numéro de commande 5601.3800.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Commençant à
Prix sur demande
Specifications
Electrical specifications
Number of output channels 2/3
Total output power max. 66 W/100 W
Maximum output power per channel 33,6 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 3 A
Voltage ripple and noise (20 Hz to 20 MHz) typ. < 1.5 mV (RMS)
< 20 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz) < 2 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 200 µs (meas.)
Programming/readback resolution voltage 10 mV
Programming/readback resolution current 1 mA
Output measurements
Readback resolution voltage 10 mV
Readback resolution current 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.1 % + 20 mV
Readback accuracy current ±(% of output + offset) < 0.1 % + 5 mA
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function -
Sink mode -
Output sequencing -
Trigger input/output -
Arbitrary function ● (EasyArb)
Analog/modulation interface -
Data logging -
Display and interfaces
Display 3.5" QVGA
Rear panel connections -
Remote control interfaces: standard USB
Remote control interfaces: optional LAN
General data
Dimensions (W × H × D) 222 mm × 97 mm × 310 mm
Weight 4.9 kg/5.0 kg
Rack installation R&S®HZC95 option

Available options

General analysis
Produit
Désignation
R&S®NGE-K101

Numéro de commande 5601.2204.03

Désignation

Ethernet Remote Control

R&S®NGE-K103

Numéro de commande 5601.2227.03

Désignation

Digital Trigger I/O

General accessories
Produit
Désignation
R&S®HZC95

Numéro de commande 5800.2054.02

Désignation

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Further information

DC Power supplies & Power analyzer promotion

Save more than 19% on fully equipped power analyzer, DC power supplies and power meter from Rohde & Schwarz.

More information

Rohde & Schwarz Power Supplies

Flyer: Power supplies. Versatile and compact.

Unique features for better results. Different power supply classes. Connectivity – everything you need.

Download now

Teaching-Software for Multi-User Student Labs

The R&S®CDS campus dashboard software simplifies teaching of student groups in laboratories with multiple workbenches.

Informations produits

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.