9 Results
Transformers are passive devices that are primarily used to convert or "transform" alternating current (AC) from one voltage level to another. One very common application of transformers is in AC to DC power supplies, in which mains voltage is stepped down before being rectified and filtered to produce DC. There are numerous other applications for transformers, such as providing electrical isolation or for impedance matching.This educational note provides a brief technical introduction to measurements made on the types of transformers used in electronics. These transformers are typically physically small, work on relatively low voltages or powers, and are used for “indoor” applications. Although many of the testing concepts described below also apply to the larger, higher-power "outdoor" transformers used for electrical power distribution, the specific tests and test procedures for these types of transformers are often specified by standards bodies such as the IEEE and may differ substantially from the types of measurements described here.Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.
28-Feb-2024
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
This application note is about measurement accuracy of the LCR-Meters R&S®LCX100 and R&S®LCX200. On the R&S®LCX100 and R&S®LCX200, the accuracy is calculated in real time, depending on the instrument settings and on the measured impedance. It is displayed on the lower part of the instrument display. If no test instrument is available, or information about the measurement accuracy at a certain measured impedance is sought without having a DUT at hand, this accuracy calculation tool provides the desired values.The document explains the background of the calculation and the prerequisites for installing and running the program. The installer provided installs the program on your PC.
11-May-2023 | AN-No. 1GP138
Ethernet based remote services for Rohde & Schwarz DC power supplies and R&S®LCX LCR meters
27-Apr-2023
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
The impedance of real-world passive components depends on frequency, signal level and DC bias. This has to be taken into account during circuit design. The R&S®LCX LCR meter is ideal for measuring these dependencies. The R&S®LCX sweep tool is an application program for conveniently performing such sweeps and displaying the results on charts.
17-Mar-2022
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
A high frequency transformer is a key component when designing isolated switching mode power supplies (SMPS). Leakage inductance is essential in the control of many design parameters including efficiency, maximum voltage rating for switching elements and EMI when it comes to designs using customized transformers. Accurate measurement of this parasitic element is mandatory. The R&S®LCX LCR meter is ideal for this challenging measurement task.
15-Feb-2022