Key facts

  • The protocol frame can be configured, including preamble, frame ID, data, CRC and more
  • Display of all decoded telegrams as color-coded bus signals or in tabular form, as defined in the frame configuration
  • Triggering on start of frame, frame ID and data. Maximum data rate for triggering of 50 Mbit/s
  • Support of up to 50 different frame formats
  • Fastest eye-diagram mask testing with standard mask test functionality
  • R&S oscilloscopes | Engineered for multi-domain challenges

Oscilloscope software

The R&S®RTO and R&S®RTE oscilloscopes support triggering and decoding of any Manchester and NRZ coded serial protocol with data rates up to 5 Gbit/s, including Manchester violation detection. You can define up to 50 different frame formats. Errors are identified reliably and efficently using the hardware-accelerated trigger. You can trigger on start of frame, frame ID and data.

Features & benefits

Fast bus setup

Bus setup in seconds with the app cockpit

Starting from the app cockpit, it only takes a few steps to configure any given protocol. Once the bus to decode has been chosen, the connected channels selected and the correct levels set, decoding begins automatically.

Open Lightbox

Bus decoding selection with the app cockpit.

Up to 50 different frame formats

Frame formats for NRZ and Manchester buses

You can define up to 50 different frame formats for any NRZ or Manchester coded protocol with data rates up to 5 Gbit/s.  

Open Lightbox

Decoded Manchester bus: Profibus PA.

Color-coded telegram display

Telegram display as color-coded bus signals and in decode table

You can analyze the decoded bus frames by overlaying the signal with color-coded data. Address and data content can be displayed in hex, bin or ASCII format. You always have the best overview with the flexible screen setup. The protocol details can also be displayed in a concise table. Select the data format and decode layer that best fits your analysis needs.

Open Lightbox

Decoded Manchester bus: Profibus PA.

Strong trigger capability

Strong trigger capability on start of frame, frame ID and data

The protocol-specific trigger lets you reliably isolate protocol events and errors. Thanks to high acquisition rates, Rohde & Schwarz oscilloscopes are ideal for finding errors quickly, allowing decoding of protocol-specific trigger results.

Open Lightbox

Custom protocol trigger setup dialog.

Search and navigate in recorded acquisitions

Powerful search and navigate capability

Comprehensive search functions simplify the analysis of long signal sequences. You can search for waveforms based on different criteria, such as signal faults or protocol content. All detected events are shown in a table with timestamps. The individual events can be examined in a zoom window with simple navigation between events.

Open Lightbox

Powerful searching, even in long recordings.

Available models


  • Option Name

    R&S®RTP-K50

    Order number 1337.8762.02

    Serial Standard
    Manchester/NRZ
    Decode Table
    Trigger
    Base unit
  • Option Name

    R&S®RTO-K50

    Order number 1329.7531.02

    Serial Standard
    Manchester/NRZ
    Decode Table
    Trigger
    Base unit
  • Option Name

    R&S®RTE-K50

    Order number 1326.1326.02

    Serial Standard
    Manchester/NRZ
    Decode Table
    Trigger
    Base unit

More information

  • Safe debugging of embedded power supplies

    Debug embedded power supplies faster by triggering and decoding their I²C-based control interfaces.

    More information

  • Triggering and decoding of low speed serial buses

    Triggering and decoding low speed serial buses

    Illustrates how to trigger and decode I²C and SPI protocols with Rohde & Schwarz oscilloscopes

    More information

Oscilloscope portfolio

  • Oscilloscopes

    Oscilloscopes that fit your requirements and your budget, from top value to top performance.

    More information

  • Oscilloscope software

    Select from a wide range of protocol triggering and decode apps, compliance testing apps, and analysis software.

    More information

  • Oscilloscope probes

    Customize your oscilloscope with the right probes and accessories for your application.

    More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

I want to receive information from Rohde & Schwarz via

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Thank you.

Your Rohde & Schwarz-Team

Leider ist bei der Übermittlung der Daten ein Fehler aufgetreten. Bitte versuchen Sie es zu einem späteren Zeitpunkt erneut.

Ihr Rohde & Schwarz-Team

General and legal information

Prices and offers are only intended for entrepreneurs and not for private end consumers.