Frequency range |
|
80 MHz to 1.0 GHz 0.69 GHz to 3.2 GHz 2.5 to 6.0 GHz |
Nominal output power |
80 MHz to 1.0 GHz |
100 W to 4200 W |
|
0.69 GHz to 3.2 GHz |
45 to 1200 |
|
2.5 GHz to 6.0 GHz |
22 W to 280 |
Nominal output load |
|
50 |
Gain flatness |
|
±3.8 dB (or better; see data sheet) |
Gain adjustment range |
|
> 15 dB |
Bias |
adjustable |
Class A through Class AB, continuous |
Mismatch tolerance |
adjustable |
VSWR 2:1 to 6:1, continuous |
Modulation capability |
|
AM, FM, φM, PM |
Nominal input impedance |
|
50 Ω |
Maximum RF input level |
|
max. +15 dBm |
Input level for nominal output power |
|
–3.4 dBm |
Nominal output impedance |
|
50 Ω |
Output mismatch tolerance, VSWR |
|
100%, without damage |
RF and sample connectors |
RF input port |
|
N female |
RF output port |
|
N female, 7/16 DIN female or 1 5/8" EIA female |
RF sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Detected sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Graphical user interface |
Local graphical display |
|
200 × 48 pixel, monochrome |
Web GUI |
via Ethernet |
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
Remote control |
Ethernet |
|
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
General data |
Operating voltage range |
R&S®BBA130-BC100, BC180, R&S®BBA130-D45-D160, R&S®BBA130-E22-E150 |
100 V to 240 V AC ± 10%, single phase, 50 Hz to 60 Hz ± 6% |
|
R&S®BBA130-E22-BC240, R&S®BBA130-E22-BC350 |
110 V to 240 V AC ± 10%, single phase, 50 Hz to 60 Hz ± 6% |
|
R&S®BBA130-BC750 R&S®BBA130-D300, D600, R&S®BBA130-E280, |
200 V to 240 V AC ± 10%, single phase, 50 Hz to 60 Hz ± 6% |
|
R&S®BBA130-BC1500-BC4200, R&S®BBA130-D1200 |
380 V to 415 V AC ± 10%, three phase, with N, 50 Hz to 60 Hz ± 6% |
Air cooling |
|
forced air, built-in fans, air entry at front, air exit at rear |
Dimensions |
Desktop model |
W × H × D, incl. fans, handles and feet |
430 mm × 196 mm × 580 mm (16.93 in × 7.72 in × 22.83 in) |
|
for rackmounting |
19" 1/1, 4 HU |
Rack models (W × H × D) |
R&S®BBA130-BC1500/-D600 |
19" × 12 HU × 800 mm |
|
R&S®BBA130-D1200 |
19" × 20 HU × 800 mm |
|
R&S®BBA130-BC1800/-BC2100/-BC2700 |
19" × 20 HU × 1000 mm |
|
R&S®BBA130-BC4200 |
19" × 35 HU × 1000 mm |
Environmental conditions |
Temperature range |
operating temperature |
0°C to +40°C |
|
storage temperature |
–20°C to +70°C |
Damp heat |
|
max. +40 °C at 95 % rel. humidity, without condensation |
Altitude |
operating altitude |
up to 2000 m |
|
storage altitude |
up to 4600 m |
Protection |
Load VSWR |
|
infinite |
Interlocks |
|
1 automatic interlock, 1 interactive interlock |
Input protection against bias voltage |
optional |
DC block level ≤ 50 V DC |
Transient voltage compatibility |
|
category II, in line with IEC60364-4-443 |
Short-circuit breaking capacity |
|
all-pole 20 A circuit breaker |
Thermal overload |
|
shutdown in case of thermal overload |