Key facts

  • Frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz
  • Outstanding single sideband (SSB) phase noise of < –134 dBc (meas.) at 1 GHz and an offset of 20 kHz
  • Very low wideband noise of < –153 dBc (typ.) at 15 MHz < f ≤ 6 GHz and an offset of 30 MHz
  • Ultra high output power of 34 dBm (meas.) at 1 GHz
  • Compact form factor with 2 HU and ¾ 19" width
  • 3 year warranty

Perfect combination of performance and usability in a compact size

The new R&S®SMB100B RF signal generator is all about performance and versatility in a small footprint. Outstanding spectral purity and very high output power combined with comprehensive functionality and very simple operation are some of the impressive features of the R&S®SMB100B. It offers a frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz.

Features & benefits

Performance and usability in a compact size

Outstanding spectral purity, very high output power and comprehensive functionality are impressive features of the R&S®SMB100B

The new R&S®SMB100B RF signal generator is all about performance and versatility in a small footprint combined with comprehensive functionality and very simple operation.

  • Frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz
  • Compact form factor with 2 HU and ¾ 19" width
  • Large, state-of-the-art 5" GUI with touchscreen

 

SMB100B RF Signal Generator
Open Lightbox

Perfect for signal quality

Very low SSB phase noise of < –134 dBc (meas.) at 1 GHz and an offset of 20 kHz

In order to improve a DUT, the signal quality of the signal source has to be significantly better than the DUT’s performance. Thanks to its innovative synthesizer design, the R&S®SMB100B has very low SSB phase and wideband noise and excellent suppression of nonharmonic signal components.

SMB100B SSB phase noise
Open Lightbox

SSB phase noise (1 GHz, 1 Hz bw, meas.)

Perfect for output power

Ultra high output power of 34 dBm (meas.) at 1 GHz

The R&S®SMBB-K31 high output power option provides 28 dBm at 1 GHz and 24 dBm at 6 GHz (measured values) – easy keycode activation. Ultra high output power of 34 dBm at 1 GHz and 31 dBm at 6 GHz with the additional R&S®SMBB-B32 ultra high output power option (measured values).

SMB100B maximum output power
Open Lightbox

Maximum output power

Perfect for use

The user friendliness of the R&S®SMB100B is evident in many ways

The RF signal generator is simple to operate, supports working with a connected R&S®NRP power sensor and can emulate legacy instruments. In addition one can create its own "user menu".

SMB100B main screen
Open Lightbox

The R&S®SMB100B main screen and user menu

Variable reference frequency inputs/outputs

The R&S®SMB100B provides various ways to output (or input) reference signals. The 1 MHz to 100 MHz variable external reference frequency input (R&S®SMBB-K704 option) allows the R&S®SMB100B to be easily integrated into existing test environments. The received reference frequency can also be output to a separate reference output (for details please refer to the data sheet). Extremely good phase stability between multiple R&S®SMB100B instruments can be achieved with the optional 1 GHz reference frequency input and output (R&S®SMBB-B3 option).

SMB100B variable reference frequency inputs/outputs
Open Lightbox

Variable reference frequency inputs/outputs

R&amp;S®LegacyPro

Refresh your T&M equipment

When individual pieces of equipment become obsolete before the entire ATE system does, regular calibration and repair of obsolete equipment is an expensive, timeconsuming and challenging task. Replacing obsolete test equipment with equivalent state-of-the-art instruments should be straightforward and require minimal hardware and software changes. The R&S®LegacyPro code emulation fulfills these requirements, reducing the workload and eliminating risks.

LegacyPro code emulation
Open Lightbox

R&S®LegacyPro code emulation

R&amp;S®NRP power sensor connectivity

An R&S®NRP power sensor can be connected to the R&S®SMB100B

A DUT is rarely connected directly to the generator. There are often cables and other components between the generator and the DUT. This shifts the reference plane from the generator’s RF output to the DUT. An R&S®NRP power sensor can be connected to the R&S®SMB100B to allow extremely precise calibration (tenth of a dB) at this new reference plane.

SMB100B extremely precise calibration
Open Lightbox

Extremely precise calibration

UCOR (user correction)

Compensation of an external frequency response by the R&S®SMB100B with a connected R&S®NRP power sensor

DUTs are often connected to the signal generator via long cables or other frequency-dependent components. It is therefore very important to compensate the frequency response. The R&S®SMB100B provides a user correction (UCOR) function for this purpose. Together with R&S®NRP power sensor the UCOR values are automatically determined by a push of a button. With UCOR, a frequency response compensated RF signal is available at the new reference plane.

SMB100B setup and UCOR function
Open Lightbox

Setup and UCOR function

Specifications
Frequency range R&S®SMBB-B101 8 kHz to 1 GHz
  R&S®SMBB-B103 8 kHz to 3 GHz
  R&S®SMBB-B106 8 kHz to 6 GHz
Level
Maximum specified output power (PEP) R&S®SMBB-B101/-B103/-B106
  standard
  200 kHz < f ≤ 1 MHz –110 dBm to +13 dBm
  1 MHz < f ≤ 10 MHz –110 dBm to +18 dBm
  10 MHz < f ≤ 6 GHz –127 dBm to +18 dBm
  with R&S®SMBB-K31 option
  200 kHz < f ≤ 1 MHz –110 dBm to +13 dBm
  1 MHz < f ≤ 10 MHz –110 dBm to +21 dBm
  10 MHz < f ≤ 4 GHz –127 dBm to +21 dBm
  4 GHz < f ≤ 6 GHz –127 dBm to +20 dBm
  with R&S®SMBB-B32 and R&S®SMBB-K31 options
  200 kHz < f ≤ 10 MHz –110 dBm to +21 dBm
  10 MHz < f ≤ 6 GHz –127 dBm to +26 dBm
Spectral purity
SSB phase noise f = 1 GHz, 20 kHz offset, 1 Hz measurement bandwidth < –126 dBc, –132 dBc (typ.)
Harmonics 1 MHz < f ≤ 6 GHz; level ≤ 13 dBm < –30 dBc
Nonharmonics CW, level > +10 dBm; offset > 10 kHz from carrier
  f ≤ 750 MHz < –80 dBc
  750 MHz < f ≤ 1500 MHz < –76 dBc
  1500 MHz < f ≤ 3 GHz < –70 dBc
  3 GHz < f ≤ 6 GHz < –64 dBc
Modulation with R&S®SMBB-K720 option AM, FM, φM
  with R&S®SMBB-K22 option pulse modulation
  On/off ratio > 80 dB
  Rise/fall time, 10 % to 90 % of RF amplitude,
f > 80 MHz, transition type: Fast
< 15 ns, < 5 ns (meas.)
  Minimum pulse width, 50 %/50 % of RF amplitude
transition type: Fast
< 20 ns
Compatible command sets command sets can be used to emulate another instrument; a subset of common commands is supported Aeroflex (IFR/Marconi), Agilent/Keysight Technologies, Hewlett Packard, Anritsu, Panasonic, Racal Dana (more details in the data sheet)

Available options

Frequency options
Product Description

R&S®SMBB-B101

Order number 1422.5005.02

Description

Frequency option

8 kHz to 1 GHz

R&S®SMBB-B103

Order number 1422.5105.02

Description

Frequency option

8 kHz to 3 GHz

R&S®SMBB-B106

Order number 1422.5205.02

Description

Frequency option

8 kHz to 6 GHz

Reference oscillator options
Product Description

R&S®SMBB-B1

Order number 1422.5305.02

Description

OCXO Reference Oscillator

Only one of the R&S®SMBB-B1 or R&S®SMBB-B1H options can be installed.

R&S®SMBB-B1H

Order number 1422.5405.02

Description

High Performance OCXO Reference Oscillator

Only one of the R&S®SMBB-B1 or R&S®SMBB-B1H options can be installed.

R&S®SMBB-B3

Order number 1422.5505.02

Description

100 MHz, 1 GHz Ultra Low Noise Reference Input and Output

R&S®SMBB-K704

Order number 1422.6301.02

Description

Variable Reference Input from 1 MHz to 100 MHz

Output power options
Product Description

R&S®SMBB-K31

Order number 1422.5705.02

Description

High Output Power, 1/3/6 GHz

R&S®SMBB-B32

Order number 1422.5740.02

Description

Ultra High Output Power 1/3/6 GHz

Requires the R&S®SMBB-K31 option.

Analog modulation options
Product Description

R&S®SMBB-K22

Order number 1422.5905.02

Description

High Performance Pulse Modulator

R&S®SMBB-K23

Order number 1422.6001.02

Description

Pulse Generator

R&S®SMBB-K24

Order number 1422.6053.02

Description

Multifunction Generator

R&S®SMBB-K27

Order number 1422.6101.02

Description

Pulse Train

Requires the R&S®SMBB-K23 option.

R&S®SMBB-K720

Order number 1422.6201.02

Description

AM/FM/φM

R&S®SMBB-B5

Order number 1422.5605.02

Description

Stereo/RDS Coder

Requires the R&S®SMBB-K720 option.

Other options
Product Description

R&S®SMBB-B86

Order number 1422.5805.02

Description

Remote Control Interface (GPIB and USB)

Recommended extras
Product Description

R&S®ZZA-KNA23

Order number 1177.8084.00

Description

19" Rackmount Kit

NRP18S-20_img_01.jpg

R&S®NRP18S-20

Order number 1424.6738.02

Description

High-power Three-path Diode Power Sensor

Measurement range: 10 nW to 15 W
Frequency range: 10 MHz to 18 GHz
N (m) connector

NRP-ZKU USB interface cable

R&S®NRP-ZKU

Order number 1419.0658.02

Description

USB interface cable, length: 0.75 m

R&S®TS-USB1

Order number 6124.2531.00

Description

USB Serial Adapter for RS-232 remote control

Documentation
Product Description

R&S®DCV-2

Order number 0240.2193.18

Description

Documentation of Calibration Values

R&S®SMBB-ACA

Order number 1422.6147.02

Description

R&S®SMB100B Accredited Calibration

Application videos

SMB100B Output power
Ultra high output power

The R&S®SMB100B offers with its ultra high output power option a calibrated one-box solution that saves space and money.

More information

SMB100B SCPI makro recorder
SCPI macro recorder

The built-in SCPI macro recorder with code generator can automatically record all manual settings and create an executable MATLAB® script.

More information

SMB100B UCOR user correction
UCOR (user correction)

With UCOR a frequency response compensated RF signal is available at the new reference plane for the DUT.

More information

Demander des informations

Vous avez des questions ou désirez des renseignements supplémentaires ? Veuillez simplement remplir ce formulaire et nous vous rappelons aussi tôt que possible.

Marketing de permission

Je souhaite recevoir des informations de Rohde & Schwarz via

Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Merci.

Votre équipe Rohde & Schwarz

Une erreur est survenue. Veuillez essayer à nouveau ultérieurement.
Informations générales et conditions d'utilisation du site Web

Prix au détail conseillé par les fabricants. Le prix ne doit pas inclure la TVA. Les prix et offres s’adressent uniquement aux professionnels et non aux particuliers.