R&S®RF Ports alignment software

R&S®RF Ports alignment software
Ingrandisci immagine
R&S®RF Ports alignment software, Screenshot

Key Facts

  • Calibration of R&S®SMW200A multi-channel setups
  • Alignment of amplitude, time and phase
  • Automated user-definable collection of correction data
  • Predefined calibration routines
  • Intuitive user interface with step-by-step user guidance

An intuitive RF ports alignment software for R&S®SMW200A multi-channel setups

With the R&S®RF Ports Alignment software together with the option R&S®SMW-K545, Rohde & Schwarz provides a standard and tailored solution for calibrating amplitude, time and phase of multi-channel SMW setups. The RF Port Alignment automatically collects the gathered correction data for the multi-channel setup using a connected vector network analyzer such as the R&S®ZNA or R&S®ZNB. 
Thanks to an intuitive graphical user interface the test engineer is guided  through the calibration procedure step-by-step in a convenient way. 
With a calibrated multi-channel setup, tests of advanced systems in wireless communication or of radar receivers can be performed straightforward.

Features & benefits

Guided calibration procedure

User friendly Grapical User Interface

The clear graphic representation of the instruments and the cabling in the Graphical User Interface of the software ensures that the setup can be set up quickly and without errors.The intuitive user interface thereby guides the user through the individual steps of calibration procedure.

Intuitive GUI of the R&S®RF Ports Alignment Software
Ingrandisci immagine

Intuitive GUI of the R&S®RF Ports Alignment Software

Calibrate and simulate precise AoA

Alignment of amplitude, time and phase

For realistic AoA simulations, the RF ports not only have to be phase-locked to each other, but precise initial calibration with regard to frequency, amplitude and phase is also necessary. The R&S®RF Port Alignment Software supports this calibration of multi-port signal generator systems automatically. Without a calibration of the RF ports, it cannot be ensured that signal differences between the RF ports are covered by properties of the test system.

Alignment of Phase, Amplitude and Time
Ingrandisci immagine

Alignment of Phase, Amplitude and Time

Calibration at the reference plane

Precise and repeatble multi-channel test setups

Since the AoA in the receiver is determined on the basis of the relative differences at the RF ports, the relative deviations of the RF ports to one another are also measured for the calibration. The ports alignment reference plane on the receiver serves as the calibration level. The deviations are automatically recorded, correction data is calculated and are loaded into the signal generators. Using the correction data, reproducible AoA are simulated.

RF ports alignment calibration setup
Ingrandisci immagine

RF ports alignment calibration setup

Simulation of angle of arrival (AoA)

White paper: Simulation of angle of arrival (AoA)

Engineers often need to test the direction finding capabilities of radar warning receivers in the lab. A perfect solution is to use multiple coupled R&S®SMW200A vector signal generators that are phase-coherent and time-synchronized.

Application videos

Rohde-Schwarz-SMW200A-RF-Ports-Alignment-Getting Started

R&S®SMW200A - RF Ports Alignment - Getting Started

Generate multiple signals aligned in amplitude, delay and phase. The video covers all the necessary steps from connecting the instruments through the configuration and alignment process.

Angle of Arrival Simulation for Multi-Channel Receivers

AoA Simulation for Multi-Channel Receivers

Testing Direction Finding Devices Using R&S®Pulse Sequencer and R&S®SMW-K545.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.