Key Facts

  • Frequency range from 9 kHz to 30 MHz
  • Maximum continuous current: 16 A (country-specific)
  • Simulated impedance: (50 μH + 5 Ω) || 50 Ω
  • Measurements in line with CISPR, EN, VDE, ANSI,
    FCC Part 15 and MIL-STD-461 standards
  • Voltage division factor: 10 dB calibrated, in line with
    CISPR 16-1-2

For disturbance voltage measurements on single-phase EUTs

For disturbance voltage measurements on single-phase EUTs

The R&S®AMN6500 two-line V-network has a simulated impedance of (50 μH + 5 Ω) || 50 Ω in the
frequency range from 9 kHz to 30 MHz. A socket with protective earth contacts is provided for connecting
the EUT. Rohde & Schwarz offers various R&S®AMN6500 models with country-specific connectors.

Features & benefits

Air-core design and artificial hand

The R&S®AMN6500 two-line V-network uses air-core inductors and contains an artificial hand in order to mimic the influence of the user’s hand while measuring the disturbance voltage.

150 kHz switch-selected highpass filter

To prevent the measuring receiver from being overdriven by high-level low-frequency spectra, a 150 kHz highpass filter can be activated.

Built-in 10 dB attenuator pad

To ensure standard-compliant impedance irrespective of the receiver input attenuation, the R&S®AMN6500 includes a 10 dB attenuator pad.

Built-in pulse limiter (can be switched off)

A built-in pulse limiter that can be switched off protects the measuring receiver input.

Remote control with TTL levels (compatible with
Rohde & Schwarz measuring receivers)

TTL control inputs that can be driven by controllers or Rohde & Schwarz measuring receivers are provided for remote control in automatic test systems (phase selection and activation of highpass filter). Optocouplers prevent pick-up of external disturbance.

Available models

Available models
Modelli
Max. continuous current
Country-specific connector

R&S®AMN6500

Order Number 1352.1313.12

Max. continuous current
16 A
Country-specific connector
Germany, Austria, Finland, the Netherlands, Norway, Russia, Sweden, Korea; occasionally: Portugal, Spain

R&S®AMN6500

Order Number 1352.1313.13

Max. continuous current
13 A
Country-specific connector
UK, Ireland, Hong Kong, Malaysia, Singapore

R&S®AMN6500

Order Number 1352.1313.16

Max. continuous current
15 A
Country-specific connector
USA, Canada, Japan, Taiwan, Mexico, Central America

Available options

General
Product
Descrizione
R&S®EZ-21

Order Number 1107.2087.03

Descrizione

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Order Number 1107.2087.10

Descrizione

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®EZ-29

Order Number 1326.6470.03

Descrizione

Control Cable, 3 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

R&S®EZ-29

Order Number 1326.6470.10

Descrizione

Control Cable, 10 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.