181 Results
This Application Note provides guidance on using the “Intermodulation Wizard” through an example measurement.
27-Mar-2013 | AN-No. 1EZ63
External generator connected via USB not correctly recognized
Save/recall files: own folder in 'Look In'
License Keycode for VNAMUC is not accepted
The MINUS key on the keypad does not work.
How can I start a SSST calibration?
This application notes introduces two alternative methods how to do the Power Added Efficiency measurement.
22-May-2013 | AN-No. 1EZ64
I want to control my Analyzer using Remote Desktop from my PC. My Analyzer does not react.
Calibration of two channels simultaneously with remote commands
I have an existing limit line. Is it possible to apply a vertical offset?
Is there a way to query the data of all traces at once?
TRL calibration - middle of line or end of line
Store several diagrams in one file and each diagram on its own page
Export complex data of a trace with mathematics and time gating.
VNA - do I really need a sliding match for calibration?
Calibrating a vector network analyzer (VNA) with different connectors on each port
The R&S®ZNB vector network analyzer together with the R&S®HF907 double-ridged waveguide horn antenna provides fast and accurate TD SVSWR measurements in line with ANSI C63.25.
06-Aug-2018
Active cal kit or cal unit does not contain all standards needed for selected cal procedure.
Rohde & Schwarz user manual for the external RFFE/GPIO interface R&S®ZN-Z15
Introduction to Attribute Based Instrument Drivers
01-Dec-2012 | AN-No. 1MA170
I have several traces with markers in one channel. When I query the result of marker 1 I always get the response of trace 1. How can I get the result of marker 1 for trace 2?
I have a file on my device. How can I get it in a simple way to my PC?
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
This application note shows how to measure the phase accurately between several signals using vector network analyzers of the R&S®ZNA, R&S®ZNB and R&S®ZNBT families.
11-Jul-2019 | AN-No. 1EZ82
Rohde & Schwarz Technical Information for the R&S ZV-Z129/-Z135/-Z170 calibration kits.
Choose Rohde & Schwarz test solutions for mixers & frequency converters for dynamic range, ease of operation and phase noise performance reasons.
Rohde & Schwarz Technical Information for the R&S ZN-Z170/-Z135/-Z129/-Z129E calibration kits.
Ensures compliance of high speed Ethernet cable assemblies with fast automation and easy testing.
04-Oct-2022
With continuously increasing data rates, signal integrity in high speed digital designs becomes more and more demanding
08-Jul-2022