53 Results
Rohde & Schwarz Realtime deembedding with the R&S®RTP
25-Sep-2018
The R&S®RT-ZPR20 and R&S®RT-ZPR40 power rail probes with a 1:1 attenuation ratio have very little noise and sufficient bandwidth to not attenuate critical signal content.
17-Jul-2018
LTE beamforming can be accurately tested with one or more R&S®RTO digital oscilloscopes for a 1×2, 1×4 or even a 1×8 MIMO system.
08-Aug-2024
Use R&S®RTP high-performance oscilloscopes and the R&S®VSE-K6A phased array measurement option for analyzing deceptive jamming techniques and automating jamer testing.
12-Jul-2021
The R&S®RTO/RTP is perfect for precise measurements in many accelerator physics lab applications, such as in synchrotrons or free electron lasers.
17-Dec-2013
This document describes the use of the R&S®RTO and R&S®RTP to demodulate RF pulses for further measurements and precisely trigger on and analyze RF pulses.
13-Mar-2019
The R&S®RTO and R&S®RTP oscilloscopes are capable of triggering precisely on a pulse as a prerequisite for time domain and frequency domain analysis.
13-Mar-2019
The R&S®RTP/R&S®RTO and R&S®VSE meet the need to verify 5G NR MIMO signals and the signal characteristics of beamforming quickly and coherent.
04-Mar-2020
How to work with acquired waveform data in Python using the R&S®RTP, R&S®RTO or R&S®RTE.
12-Jan-2022
High-speed serial interfaces often transmit data with differential signaling and differential probes can be used to access signal traces. In addition to differential inputs, these probes have a ground connection.
02-Nov-2022
The R&S®RTP and R&S®RTO oscilloscopes are capable of characterizing high speed datacom interfaces and performing in-depth signal integrity analysis.
15-Jul-2024
This application note focuses on how to measure and analyze FMCW radar signals with up to 6 GHz bandwidth with an R&S® RTP oscilloscope.
07-Aug-2019 | AN-No. GFM318
High dynamic range current measurements on IoT devices
01-Oct-2019
The R&S®RTO digital oscilloscope analyzes RF pulses up to the maximum bandwidth of the instrument used.
09-Nov-2017
The digital trigger of the R&S®RTP combined with the zone trigger offers versatile and flexible triggering capabilities for DDR memory interface measurements.
26-Sep-2018
It is recommended to use jitter measurement instruments for both the time and frequency domain in order to differentiate between fast and slow moving artifacts.
22-Aug-2017
Verifying power integrity for DDR memories - The R&S ® RT-ZPR20 power rail probe is a specialized oscilloscope probe for very low-noise measurements on power.
05-Apr-2017
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO, multi-antenna radar and differential high-speed digital signals.
06-May-2020
This application note describes two test solutions from R&S® to cope with the 5G FR1 downlink MIMO signal analysis challenges either using R&S®RTP/RTO oscilloscope or R&S®NRQ6 frequency selective power sensor.
26-Jun-2020 | AN-No. GFM343
For system verification and debugging, eye diagram measurements are the most important tools for efficiently analyzing the signal integrity in any digital design
19-Feb-2019
The application fields of oscilloscopes extend to EMI debugging because of their powerful and easy-to-use FFT analysis capabilities– and save time and money.
23-Sep-2019
This application note describes Battery Life Measurements with the R&S®RT-ZVC02/04 Multi-Channel Probe. The measurements are described with the use of an oscilloscope.
17-Jan-2019 | AN-No. 1TD07
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
Read this application card to learn more about what the 10BASE-T1S Ethernet compliance test offers and how it ensures reliable operation and functionality.
15-May-2020
This application note provides an introduction to the DDR memory technology and explains common challenges, related to the specific nature of DDR data, command and control buses.
30-Oct-2020 | AN-No. GFM340
To allow optimization early on in the R&D lab, Rohde & Schwarz provides a free tool to simplify conducted emissions debugging using oscilloscopes.
27-Sep-2021 | AN-No. 1SL372
EMI Debugging with the R&S RTO and R&S RTE Oscilloscopes
25-Jun-2014 | AN-No. 1TD05
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410
This app note provides an introduction into the various jitter components and elucidates the commonly available jitter separation frameworks.
08-Dec-2021 | AN-No. 1SL375
Generating models with a VNA and using these on an oscilloscope via the deembedding
23-May-2023 | AN-No. 1SL393