30 Results
Oscilloscope users consistently rate bandwidth, sample rate, and memory depth as the three most important specifications. Selecting an oscilloscope with deep memory can result in significant troubleshooting and debug time saving. This document provides the insight to allow readers to understand oscilloscope memory depth attributes, benefits, and determine how to consider when choosing your next oscilloscope.
01-May-2023
Triggering is often overlooked as a key selection parameter until after the instrument is purchased. Digital triggering provides significant advantages over traditional oscilloscope analog triggering, and should be highly considered when choosing an oscilloscope. Newer oscilloscope architectures contain a single path shared by both the signal and triggering, known as digital triggering. This document provides the insight to allow readers to understand and compare digital triggering versus analog triggering.
24-Apr-2023
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
Rohde & Schwarz has made a breakthrough for better jitter and noise separation with the launch of SW options (RT-K133 & RT-K134). Technical information on this new algorithm were presented at . We received a lot of positive feedback on this new technique. However, one fundamental question still remained. How does this new algorithm compare to established solutions available on the market today?This app note provides an introduction into the various jitter components and elucidates the commonly available jitter separation frameworks. Finally, it provides a comparison between the different commercial solutions, while explaining the used waveforms and signals to achieve the results. Curios? Read on, to learn how Rohde & Schwarz’s new option for jitter and noise separation delivers dependable and stable results. If you are interested in evaluating on your own, you may download the waveform files with registration.
08-Dec-2021 | AN-No. 1SL375
In general, most of the existing electronic devices are connected to the AC mains and require a power conversion stage to convert the AC-Voltage to a smaller DC-Voltage. Voltages and frequencies of the power grid differ between different regions. However, different types of AC-DC conversion stages exist to supply the electronic equipment with adequate DC-power.In AC-DC conversion combined with power levels less than 50W, the flyback converter is a commonplace chosen topology because of its simplicity and its low cost. The majority of consumer products make use of this converter type like wall brick power supplies or power adapters for any consumer application and other type of stand-by auxiliary power supply like used in white and brown goods. In AC to DC converter application, an electrical isolation between input and output is mandatory. The flyback topology provides this galvanic barrier.Beside the common advantages of a flyback converter, it has inherently parasitic components, which typically produce ringing waveforms with considerably high voltage spikes. Without suppressing this unwanted ringing, it may have some negative effect on other components like the switching elements. This ringing can also influence the EMI emissions adversely. Therefore, it is an important task to adequate suppress and damp the ringing effect. This damping circuit is known as snubber circuit and provides this functionality. In the flyback converter, different snubber structures can be applied and each of the structure has its advantage and disadvantage.The demand having a snubber circuit in the power supply topology leads to specific verification methods during the design to obtain a proper and reliable design. These verification methods are the main focus of the discussions within this document.
23-Jun-2021 | AN-No. 1SL363
Almost every switched-mode power supply (SMPS) needs an EMI (Electro Magnetic Interference) input filter to suppress any disturbances of the SMPS on the power lines. This requirement having an input filter in the design ensures that no negative effect will occur in other parts of the systems connected to the power lines. Therefore, the design and the validation of the input filter is a major task during a typical power supply design. The conducted emission (CE) test according to a specific standard is a suitable and a common validation method to release the design at the end of the development cycle. Nowadays, this conducted emission test will be performed as pre-compliance test during the development phase in the lab as well. In this case, the designer will obtain an early feedback whether the design has to be optimized regarding any disturbances present on the power lines. In most cases, the designer has to adjust the input filter to obtain a more effective suppression of disturbances generated by the SMPS. However, the designer needs to know details about the noise spectrum to optimize the input filter as effective as possible. In addition to magnitude and frequency information of the noise source, it would be very helpful to know whether the noise is generated by a common mode source or by a differential mode source. During the standard conducted emission test, common and differential mode noise is a combination in the measurement results and thus not possible to gain deeper insights. This document will describe a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component like a noise separator. The designer will be able to distinguish between common-mode (CM) and differential-mode (DM) noise. This additional information about the dominant mode provides the capability to optimize input filters very efficiently.
17-Sep-2020 | AN-No. GFM353
5G New Radio (NR) FR1 MIMO or beamforming downlink signal analysis especially the phase measurement of each MIMO layer and the determination of the phase difference between the MIMO layers are essential for the 5G base station product design.In this application note, it describes two test solutions from R&S® to cope with the 5G FR1 downlink MIMO signal analysis challenges either using R&S®RTP/RTO oscilloscope or R&S®NRQ6 frequency selective power sensor as RF frontend to capture the signal and together with R&S®VSE as post-processing tool for the IQ analysis.The aim of this application note is to walk the user through the necessary steps on both test solutions to enable the 5G FR1 downlink MIMO signal analysis.It is assumed that the reader has certain pre-knowledge of 5G NR physical layer. In case a refreshment is needed, please refer to the for further reading.
26-Jun-2020 | AN-No. GFM343
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications. R&S®VISA also includes a trace tool that simultaneously monitors communications between multiple applications and T&M instruments, and permits targeted analysis with the aid of efficient filters.
26-May-2020 | AN-No. 1DC02
This application note describes Battery Life Measurements with the R&S®RT-ZVC02/04 Multi-Channel Probe. The measurements are described with the use of an oscilloscope. The R&S®RT-ZVC Multi-Channel Probe can be used with R&S®RTE1000, R&S®RTO2000 or R&S®RTP.
17-Jan-2019 | AN-No. 1TD07
EMI compliance is becoming a major concern for advanced power electronics due to increasing switching speeds. Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
22-Nov-2018
Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Using R&S®Forum Application for Instrument Remote Control Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Related products
28-Jun-2018 | AN-No. 1MA196
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
Before devices can be used in a LoRaWANTM network, they must among other things meet country-specific wireless communications regulations. This application note shows developers and manufacturers of devices with LoRa wireless technology how transmitter measurements are conducted in line with FCC Part 15.247. It also describes how important receiver characteristics can be verified by metrological means. In this context, battery life in particular plays a key role in IoT applications. A further chapter describes how current consumption of LoRa wireless modules can be measured reliably.
29-Nov-2017 | AN-No. 1MA295
This application note outlines two different approaches for remote-controlling Rohde & Schwarz instruments out of MathWorks MATLAB:The first one uses VISA connection and direct SCPI commands.The second approach takes advantage of Rohde & Schwarz VXI plug&play instrument drivers and MATLAB Instrument Control Toolbox.
12-Jun-2017 | AN-No. 1MA171
This Application Note gives 10 useful Tips & Tricks for the users of Rohde & Schwarz attribute-based instrument drivers. It is recommended for the first-time LabVIEW users as well as for the experienced programmers.
30-Jan-2017 | AN-No. 1MA228
RF pulse measurements, to characterize the signal in the frequency domain, are traditionally carried out on an RF spectrum analyzer. For time related pulse parameters, oscilloscopes are widely used. However, the measurement capabilities of state of the art test and measurement equipment has evolved over time and crosses domains. With a combination of R&S®RTO digital oscilloscope and dedicated pulse analysis software R&S®VSE-K6, pulse signals can be analyzed in both domains, frequency and time.The R&S®RTO digital oscilloscopes are unique in that they allow output of I/Q data for processing. This application note focusses on signal measurement using this instrument.Analysis of an L-/S-band ATC RADAR utilizing the R&S®RTO2044 oscilloscope running Vector Signal Explorer Software R&S®VSE and Pulse Analysis personality R&S®VSE-K6 is followed by measurements on an X-band RADAR utilizing R&S®FSW, R&S®FPS, R&S®FSV or FSVA signal & spectrum analyzers with the same dedicated R&S®VSE-K6 software.
18-Oct-2016 | AN-No. 1MA249
Designing and implementing an active phased array antenna requires precise characterization of individual components and the integrated performance of the array. To ensure an accurate test of the intended adaptive nature of the active phased array antenna, the embedded algorithms need to be tested as well.This application note aims to explain test procedures and give recommendations towards characterization of the relevant parameters for active phased array antennas and their passive subsystem, as often used in applications for Mobile Communication and RADAR. This application note describes transmit signal quality testing, multi-element amplitude and phase measurement techniques both in receive and transmit cases and introduces a new automated test methodology antenna radiation pattern measurement over frequency. This paper also describes the test system used for transmit and receive module (TRM) characterization in active array antennas.
04-Jul-2016 | AN-No. 1MA248
Road safety is a global challenge at present and will be in the future. Automotive radar has become a keyword in this area and pushes again a step forward to increase driving comfort, crash prevention and even automated driving.Driver assistance systems which are supported by radar are already common. Most assistant systems are increasing the drivers comfort by collision warning systems, blind-spot monitoring, adaptive cruise control, lane-change assistance, rear cross-traffic alerts and back-up parking assistance.Today's 24 GHz, 77 GHz and 79 GHz radar sensors clearly need the capability to distinguish between different objects and offer high range resolution. That is possible with increased signal bandwidth.Furthermore, those radar systems need to cope with interference of many kinds like the one from other car's radar.This Application Note addresses signal measurements and analysis of automotive radars that are crucial during the development and verification stages. It also shows a setup to verify the functionality of a radar in case of radio interference.
10-Jun-2016 | AN-No. 1MA267
This paper explains how to use the Rohde & Schwarz IVI.NET instrument drivers in Visual Studio environment from the prospective of an occasional C# programmer in need of automating a measurement task.
31-May-2016 | AN-No. 1MA268
This application note explains how to convert different Rohde & Schwarz I/Q file formats among each other using the supplied software tool.
23-Sep-2015 | AN-No. 1EF85
Generation of wideband digital modulated signals in V-band and above is a challenging task and typically requires a set of multiple instruments. This application note aims at simplifying the task and looks into the analysis part as well. Latest signal and spectrum analyzers like the R&S®FSW67 and R&S®FSW85 are first to allow use in V-band up to 67 GHz and E-band up to 85 GHz respectively without external frequency conversion. Up to 8.3 GHz of modulation bandwidth can be covered using the R&S®FSW-B8001 option. Millimeter wave use of analyzers ranging from 26 GHz up is shown. Application note 1MA217 describes V-band signal generation and analysis up to 500 MHz modulation bandwidth. This application note expands modulation bandwidth up to 2 GHz and covers both V- and E-band examples.
18-Jun-2015 | AN-No. 1MA257
Verification of the spectrum allocation and in depth analysis of the transmitted signals is very important in many domains. For example, the IEEE 802.11ad standard makes use of approximately 2 GHz bandwidth in the 60 GHz frequency domain. Researchers and developers of Automotive radar discuss the 79 GHz frequency band with an available bandwidth of up to 4 GHz. Finally the upcoming 5G technology for cellular networks discusses the use of up to 2GHz signals in the cm and mm-wave frequency bands.This technical evolution already indicates the need of signal measurement and analysis in the mm-wave domain with high bandwidth.Therefore, this application note presents a method to measure and analyze signals with an instantaneous bandwidth of up to 2 GHz using new tools on the R&S®FSW Signal and Spectrum Analyzer platform in collaboration with an R&S®RTO Digital Oscilloscope.
16-Jun-2015 | AN-No. 1EF92
With the R&S®RTO-K17/RTE-K17 High Definition Option the user will see more signal details with up to 16 bit vertical resolution.In combination with the superior analog front end of the R&S®RTO and R&S®RTE, the user has a versatile instrument in his hands to analyze a wide range of applications. From Switch Mode Power Supplies to Radar RF, the user can inspect all with one scope.
13-Apr-2015 | AN-No. 1TD06
This application note introduces the IVI High Speed LAN Instrument Protocol (HiSLIP) and outlines its features. HiSLIP is the successor to the VXI-11 LAN remote control protocol. This document also describes guidelines for using this protocol.
12-Nov-2014 | AN-No. 1MA208
This application note offers a straightforward description of how to analyze EMI problems using the Rohde & Schwarz Oscilloscopes. The discussion begins by covering the basic mechanisms that can result in unwanted RF emissions and then describes how to proceed in analyzing EMI problems. Finally, a practical example is given to illustrate the analysis process.
25-Jun-2014 | AN-No. 1TD05
Rare faults and intermittent signals are difficult to capture. The R&S®RTO Oscilloscope supports the acquisition and the detailed signal analysis of these signals by using the history mode. The history mode allows the user to look back to previous acquisitions and apply the wide set of analysis functions of the RTO. Furthermore it stores the accurate recoding time of the waveforms for subsequent analysis.
03-Jun-2013 | AN-No. 1TD02
Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC Testing LTE MIMO Signals using a R&S RTO Oscilloscope Testing LTE MIMO Signals using a R&S®RTO Oscilloscope Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC Testing LTE MIMO Signals using a R&S RTO Oscilloscope Related products
24-Apr-2013 | AN-No. 1EF86
The aim of this application note is to provide information regarding Rohde & Schwarz instrument drivers. This paper shall help application engineers and software developers to easily get an understanding of advanced techniques to develop test and measurement (T&M) applications by utilizing Rohde & Schwarz instrument drivers. Furthermore the nomenclature used for Rohde & Schwarz instrument drivers will be explained.
01-Jan-2013 | AN-No. 1MA153
The effective number of bits (ENOB) is a way of quantifying the quality of an analog to digital conversion. A higher ENOB means that voltage levels recorded in an analog to digital conversion are more accurate. In an oscilloscope the ENOB is not just determined by the quality of the analog to digital converter but by the instrument as a whole. This application note explains how to measure the oscilloscope ENOB and shows results for the R&S®RTO for different settings.
13-May-2011 | AN-No. 1ER03