R&S®ZN-Z8x switch matrix

R&S®ZN-Z8x switch matrix
Open Lightbox
R&S®ZN-Z8x switch matrix, Side view

Key facts

  • Full crossbar measurements up to 48 ports
  • Easy setup with the R&S®ZNB; R&S®ZND; R&S®ZNBT
  • Ready to use, no need to configure matrix hardware externally
  • Supports use of automated calibration units with up to 24 ports
  • Remote control: LAN, USB, Direct Connect
  • 3-year warranty extension

Engineered for multiport VNA measurements

Components used in modern communications equipment, such as frontend smartphone and tablet PC frontend modules, must support ever more frequency bands and functions such as WLAN, Bluetooth® and GPS. This means the number of module RF ports is also growing, not least due to the use of various different components. The R&S®ZNB in combination with various switch matrices provides a comprehensive solution for complex measurements of  modules with up to 48 ports. Rohde & Schwarz matrices deliver full crossbar measurements, enabling determination of all multiport DUT S-parameters.

Features & benefits

Easy configuration

Configure a multiport VNA with the push of a button

The R&S®ZNB controls switch matrices via LAN, USB or dedicated digital interface. A four-port VNA model allows up to two switch matrices to be combined for characterizing a DUT with up to 48 ports. Once a matrix is connected, the R&S®ZNB automatically detects the matrix and assigns test ports to immediately start measuring. Measurement parameters are directly selected and displayed on the user interface, eliminating the need for additional software.

Automatic assignment of test ports in the R&S®ZNB
Open Lightbox

Automatic assignment of test ports in the R&S®ZNB

RF characteristics

Fast measurements and excellent RF characteristics

Switch matrices from Rohde & Schwarz have very short switching times for enhanced measurement speed especially for sweeps of a small number of points. The compact design and state-of-the-art electronic switches in the R&S®ZN-Z84 and R&S®ZN-Z85 switch matrices have low insertion loss. Other highlights include good test port match and a high compression point for measurements on active DUTs with output power levels up to +20 dBm.

Open Lightbox

Calibration

Easy calibration with multiport calibration unit

Calibrating multiple ports is not easy, especially when it has to be done manually. Rohde & Schwarz has multiport calibration units where each port must only be connected once, making things much easier when up to 48 ports have to be calibrated. For even more convenience, the R&S®ZN-Z154 can be also be used to calibrate up to 24 ports at once.

Open Lightbox

Diverse application

Matrix solutions for every application

Rohde & Schwarz has switch matrices for many applications. Matrix models are available with up to 20 GHz and 24 outputs. Users can select the optimum configuration for low insertion loss, maximum accuracy and a high port number. A four-port R&S®ZNB can also be combined with a two input matrix (mixed configuration). The remaining two ports on the network analyzer can be used as regular VNA ports with the superior R&S®ZNB performance.

Mixed configuration: analyzer and matrix plus high-performance VNA ports
Open Lightbox

Mixed configuration: analyzer and matrix plus high-performance VNA ports

Available models

Available models
Models
Type
Frequency range
Number of ports
Connector type
Description
R&S®ZN-Z84

R&S®ZN-Z84

Order number 1319.4500.02

Type
Switch matrix
Frequency range
10 MHz to 8.5 GHz
Number of ports
up to 24 test ports
Connector type
SMA (f)
Description
Switch matrix to support full crossbar measurements up to 48 ports. Easy setup with the R&S®ZNB, R&S®ZNBT or R&S®ZND families.
R&S®ZN-Z85

R&S®ZN-Z85

Order number 1326.4777.03

Type
Switch matrix
Frequency range
10 MHz to 20 GHz
Number of ports
up to 12 test ports
Connector type
SMA (f)
Description
Switch matrix to support full crossbar measurements up to 12 ports. Easy setup with the R&S®ZNB, R&S®ZNBT and R&S®ZND families.

Available options

Configurable R&S®ZN-Z84 switch matrix up to 8.5 GHz
Product
Description
R&S®ZN-Z84-B22

Order number 1319.4969.22

Description

Additional test ports 7 to 12, 2 VNA ports to 12 test ports

The R&S®ZN-Z84 base unit is a prerequisite.

R&S®ZN-Z84-B24

Order number 1319.4969.24

Description

Additional test ports 7 to 12, 4 VNA ports to 12 test ports

The R&S®ZN-Z84 base unit is a prerequisite.

R&S®ZN-Z84-B32

Order number 1319.4969.32

Description

Additional test ports 13 to 18, 2 VNA ports to 18 test ports

The R&S®ZN-Z84 base unit and R&S®ZN-Z84-B22 are prerequisites.

R&S®ZN-Z84-B34

Order number 1319.4969.34

Description

Additional test ports 13 to 18, 4 VNA ports to 18 test ports

The R&S®ZN-Z84 base unit and R&S®ZN-Z84-B24 are prerequisites.

R&S®ZN-Z84-B42

Order number 1319.4969.42

Description

Additional test ports 19 to 24, 2 VNA ports to 24 test ports

The R&S®ZN-Z84 base unit and the R&S®ZN-Z84-B32 are prerequisites.

R&S®ZN-Z84-B44

Order number 1319.4969.44

Description

Additional test ports 19 to 24, 4 VNA ports to 24 test ports

The R&S®ZN-Z84 base unit and the R&S®ZN-Z84-B34 are prerequisites.

Configurable Switch Matrix R&S®ZN-Z85 up to 20 GHz
Product
Description
R&S®ZN-Z85-B24

Order number 1326.4831.26

Description

Additional test ports 7 to 12, 4 VNA ports to 12 ports

General accessories
Product
Description
R&S®ZN-Z28

Order number 1326.6605.02

Description

Semi-rigid cables N (m) - 3.5 mm (m)

Connects two 2-to-24 port R&S®ZN-Z84 units to a four-port R&S®ZNB4/8

R&S®ZN-B121

Order number 1323.9290.00

Description

Direct control cable

R&S®ZZA-KN2

Order number 1175.3010.00

Description

19" Rack Adapter

For mounting a 19" housing 2 RU high in a standard 19" rack

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. Draw Period. This Draw begins January 01, 2020 to December 31, 2020. R&S reserves the right to change the end date of the Draw.

3. Participation. No purchase necessary. This Draw is limited to legal residents of the United States and Canada, age of 18 years or older, at the time of the submission. Employees of R&S, its affiliates, subsidiaries, distribution partners and agents, and immediate family members of each, are not eligible. Government agencies and institutions (including public universities), and their employees are not eligible to participate or receive prizes. This Draw is void where prohibited by law.

4. Entrance. Fill out the form above during the Draw Period and follow the instructions to complete and submit the form. Limit one entry per person. R&S, in its sole, reasonable discretion, reserves the right to disqualify any entries by persons determined to be tampering with or abusing any aspect of this Draw. An entrant must provide their name, address, and email address to be considered eligible.

5. Data Protection and Privacy Policy. An entrant must provide personal data such as name, address and email address to be considered eligible. This data will be used to make the necessary contact information available for purposes of notifying the winner. In addition to notification purposes, the data collected will be used for marketing purposes and the entrant agrees to allow R&S to contact them. The personal data that has been received from you and saved will not be sold by Rohde & Schwarz to third parties. It may, however, be necessary to disclose your personal data to Rohde & Schwarz service providers for business purposes, so that they can provide services for Rohde & Schwarz. The Rohde & Schwarz websites may contain links to other websites. This statement of privacy does not cover these other websites and Rohde & Schwarz cannot assume any responsibility whatsoever, neither for the privacy practices nor the content of these other websites. Further information regarding data protection and privacy can be found at: http://www.rohde-schwarz.us/en/general_information/statement-of-rivacy_101515.html.

6. Prize Description. There will be one (1) winner for each of one (1) of ten (10) R&S®RTB2000 Digital Oscilloscopes. R&S reserves the right to substitute a prize of equal or greater value in the event that the stated prize becomes unavailable. No cash equivalent or exchange is permitted. All federal, state and/or local income and other taxes or duties, if any, are the winner's sole responsibility.

7. Odds of Winning. The odds of winning this Draw depend on the number of eligible entries received.

8. Winners Selection. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich.

9. Winner Notification. The winners of each of the prizes will be informed by e-mail within five (5) working days. The participant that is selected as winner of the prize shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

10. Limitation of Liability. By entering, entrants release and hold harmless Rohde & Schwarz and its respective parents, subsidiaries, affiliates, directors, officers, employees and agents from any and all liability or any injuries, loss, or damage of any kind arising from or in connection with this Draw or with any prize awarded. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

11. Internet. If for any reason the Internet portion of the Draw is not capable of running as planned, including infection by computer virus, bugs, tampering, unauthorized intervention, fraud, technical failures, or any other causes beyond the control of R&S or its third-party providers that corrupt or affect the administration, security, fairness, integrity or proper conduct of this Draw, R&S reserves the right, at its sole discretion, to cancel, terminate, modify, or suspend the Draw, and to disqualify any individual who tampers with the entry process.

R&S assumes no responsibility for any error, omission, interruption, deletion, defect, delay in operation or transmission, communications-line failure, theft, or destruction or unauthorized access to, or alteration of, entries. R&S is not responsible for any problems or technical malfunction of any telephone network or lines, computer online systems, servers or providers, computer equipment, or software, or for failure of any email or entry to be received by Rohde & Schwarz on account of technical problems or traffic congestion on the Internet or at any Web site, or any combination thereof, including any injury or damage to participant's or any other person's computer related to or resulting from participation or downloading any materials in this Draw.

12. General Conditions.

a. Entrants agree to abide by the terms of these official rules and by the decisions of R&S, which are final and binding on all matters pertaining to this Draw. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Draw. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Draw.

b. Income Taxes: A U.S. winner will need to supply to R&S their Social Security Number for a 1099 for the total value (Current estimate is approximately $1,540) to be issued. Any winner is solely responsible for any and all tax liability/responsibility for this. R&S is not responsible for any taxes or tax implications to or of the winner associated with Draw winnings.

13. Winner Information. For the names of the winners, send a self-addressed stamped envelope to Rohde & Schwarz USA, Inc. at 6821 Benjamin Franklin Drive, Columbia, MD 21046.

ATTN: Winner – Rohde & Schwarz’ 10 years Rohde & Schwarz oscilloscopes Draw. Requests received after January 1, 2021, will not be fulfilled.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.