R&S®ZVAX-TRM extension unit

Configurable signal conditioning for measurements on active components

R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit, Front viewR&S®ZVAX-TRM extension unit, Front viewR&S®ZVAX-TRM extension unit, Side viewR&S®ZVAX-TRM extension unit, Back viewR&S®ZVAX-TRM extension unit, Side view

Key facts

  • Extension unit for the R&S®ZVA/ZVT network analyzer
  • For measurements of T/R modules, receivers, transceivers, power amplifiers
  • Base unit ready for high power measurements
  • R&S®ZVAX-TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application
  • 3-year warranty extension

Extension unit for measurements on active components

Configurable signal conditioning for R&S®ZVA/ZVT

The configurable R&S®ZVAX‑TRM extension unit is used with an R&S®ZVA/R&S®ZVT network analyzer to provide signal conditioning for demanding measurements on active devices under test. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides customized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Features & benefits

Configurable test system

Flexible characterization of T/R modules

The R&S®ZVAX‑TRM is an extension unit for the R&S®ZVA/ZVT. The configurable external box adds hardware components required for transmit/receive modules or high-power testing. The base unit has two ports, couplers, and path access loops. Modules can be added as needed: output pre-amplifiers, combiners, pulse modulators, receiver pre-amplifiers. Uncoupling the options from the VNA protects it and maintains  full RF performance for the base unit when measuring without the R&S®ZVAX-TRM.

Convenient control via a graphical user interface
Open Lightbox

Convenient control via a graphical user interface

Excellent performance

Excellent performance data for measurements on T/R modules

The T/R module characteristics can be measured in both directions, making bidirectional pulse measurements possible. High output power levels are standard, even with a fully configured R&S®ZVAX-TRM.

Compact solution with open architecture

Signal access points to integrate external components and instruments

Measuring power or pulse profile calls for different test setups. To meet these requirements, the R&S®ZVAX-TRM offers the following:

  • Access to generator path (e.g. connect external power amplifiers)
  • Access to receiver path (e.g. connect attenuators for power measurements or to output signal to an external instrument)
  • Access to reverence signal (e.g. to utilize automatic level control)

Open Lightbox

Customized configuration

Get what you need

The R&S®ZVAX-TRM extension unit in its base configuration supports high-power two-port measurements up to +43 dBm (pulsed signals) and can easily loop in external components.
For greater flexibility the R&S®ZVAX-TRM functions can be expanded with diverse options such as:

  • pulse modulators
  • low-noise preamplifiers
  • output amplifiers
  • combiners

Open Lightbox

Available models

Available models
Models
Frequency range

R&S®ZVAX-TRM24

Order number 1322.6500.24

Frequency range
24 GHz

R&S®ZVAX-TRM40

Order number 1322.6500.40

Frequency range
40 GHz

R&S®ZVAX-TRM50

Order number 1322.6500.50

Frequency range
50 GHz

R&S®ZVAX-TRM67

Order number 1322.6500.67

Frequency range
67 GHz

Available options

R&S®ZVAX-TRM24 extension unit
Product
Description
R&S®ZVAX24B31

Order number 1322.7020.24

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 1

R&S®ZVAX24B32

Order number 1322.7036.24

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 2

R&S®ZVAX24B712

Order number 1322.6969.24

Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B73

Order number 1322.6975.24

Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX24B112

Order number 1322.6981.24

Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B134

Order number 1322.6998.24

Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at network analyzer port 3 and port 4 or at R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX24B213

Order number 1322.7007.24

Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX24B224

Order number 1322.7013.24

Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM40 extension unit
Product
Description
R&S®ZVAX40B31

Order number 1322.7020.40

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 1

R&S®ZVAX40B32

Order number 1322.7036.40

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 2

R&S®ZVAX40B712

Order number 1322.6969.40

Description

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B73

Order number 1322.6975.40

Description

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX40B112

Order number 1322.6981.40

Description

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B134

Order number 1322.6998.40

Description

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX40B213

Order number 1322.7007.40

Description

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX40B224

Order number 1322.7013.40

Description

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM50 extension unit
Product
Description
R&S®ZVAX50B31

Order number 1322.7020.50

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 1

R&S®ZVAX50B32

Order number 1322.7036.50

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 2

R&S®ZVAX50B712

Order number 1322.6969.50

Description

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B73

Order number 1322.6975.50

Description

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX50B112

Order number 1322.6981.50

Description

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B134

Order number 1322.6998.50

Description

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX50B213

Order number 1322.7007.50

Description

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX50B224

Order number 1322.7013.50

Description

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM67 extension unit
Product
Description
R&S®ZVAX67B31

Order number 1322.7020.67

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 1

R&S®ZVAX67B32

Order number 1322.7036.67

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 2

R&S®ZVAX67B712

Order number 1322.6969.67

Description

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B73

Order number 1322.6975.67

Description

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX67B112

Order number 1322.6981.67

Description

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B134

Order number 1322.6998.67

Description

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX67B213

Order number 1322.7007.67

Description

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX67B224

Order number 1322.7013.67

Description

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. Draw Period. This Draw begins January 01, 2020 to December 31, 2020. R&S reserves the right to change the end date of the Draw.

3. Participation. No purchase necessary. This Draw is limited to legal residents of the United States and Canada, age of 18 years or older, at the time of the submission. Employees of R&S, its affiliates, subsidiaries, distribution partners and agents, and immediate family members of each, are not eligible. Government agencies and institutions (including public universities), and their employees are not eligible to participate or receive prizes. This Draw is void where prohibited by law.

4. Entrance. Fill out the form above during the Draw Period and follow the instructions to complete and submit the form. Limit one entry per person. R&S, in its sole, reasonable discretion, reserves the right to disqualify any entries by persons determined to be tampering with or abusing any aspect of this Draw. An entrant must provide their name, address, and email address to be considered eligible.

5. Data Protection and Privacy Policy. An entrant must provide personal data such as name, address and email address to be considered eligible. This data will be used to make the necessary contact information available for purposes of notifying the winner. In addition to notification purposes, the data collected will be used for marketing purposes and the entrant agrees to allow R&S to contact them. The personal data that has been received from you and saved will not be sold by Rohde & Schwarz to third parties. It may, however, be necessary to disclose your personal data to Rohde & Schwarz service providers for business purposes, so that they can provide services for Rohde & Schwarz. The Rohde & Schwarz websites may contain links to other websites. This statement of privacy does not cover these other websites and Rohde & Schwarz cannot assume any responsibility whatsoever, neither for the privacy practices nor the content of these other websites. Further information regarding data protection and privacy can be found at: http://www.rohde-schwarz.us/en/general_information/statement-of-rivacy_101515.html.

6. Prize Description. There will be one (1) winner for each of one (1) of ten (10) R&S®RTB2000 Digital Oscilloscopes. R&S reserves the right to substitute a prize of equal or greater value in the event that the stated prize becomes unavailable. No cash equivalent or exchange is permitted. All federal, state and/or local income and other taxes or duties, if any, are the winner's sole responsibility.

7. Odds of Winning. The odds of winning this Draw depend on the number of eligible entries received.

8. Winners Selection. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich.

9. Winner Notification. The winners of each of the prizes will be informed by e-mail within five (5) working days. The participant that is selected as winner of the prize shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

10. Limitation of Liability. By entering, entrants release and hold harmless Rohde & Schwarz and its respective parents, subsidiaries, affiliates, directors, officers, employees and agents from any and all liability or any injuries, loss, or damage of any kind arising from or in connection with this Draw or with any prize awarded. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

11. Internet. If for any reason the Internet portion of the Draw is not capable of running as planned, including infection by computer virus, bugs, tampering, unauthorized intervention, fraud, technical failures, or any other causes beyond the control of R&S or its third-party providers that corrupt or affect the administration, security, fairness, integrity or proper conduct of this Draw, R&S reserves the right, at its sole discretion, to cancel, terminate, modify, or suspend the Draw, and to disqualify any individual who tampers with the entry process.

R&S assumes no responsibility for any error, omission, interruption, deletion, defect, delay in operation or transmission, communications-line failure, theft, or destruction or unauthorized access to, or alteration of, entries. R&S is not responsible for any problems or technical malfunction of any telephone network or lines, computer online systems, servers or providers, computer equipment, or software, or for failure of any email or entry to be received by Rohde & Schwarz on account of technical problems or traffic congestion on the Internet or at any Web site, or any combination thereof, including any injury or damage to participant's or any other person's computer related to or resulting from participation or downloading any materials in this Draw.

12. General Conditions.

a. Entrants agree to abide by the terms of these official rules and by the decisions of R&S, which are final and binding on all matters pertaining to this Draw. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Draw. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Draw.

b. Income Taxes: A U.S. winner will need to supply to R&S their Social Security Number for a 1099 for the total value (Current estimate is approximately $1,540) to be issued. Any winner is solely responsible for any and all tax liability/responsibility for this. R&S is not responsible for any taxes or tax implications to or of the winner associated with Draw winnings.

13. Winner Information. For the names of the winners, send a self-addressed stamped envelope to Rohde & Schwarz USA, Inc. at 6821 Benjamin Franklin Drive, Columbia, MD 21046.

ATTN: Winner – Rohde & Schwarz’ 10 years Rohde & Schwarz oscilloscopes Draw. Requests received after January 1, 2021, will not be fulfilled.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.