Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
93 Results
Today’s complex circuits must integrate several components that feed on different power levels. A robust circuit that ensures interoperability of these components needs carefully designed, clean and stable power distribution networks for power timing. At lower voltage levels, tolerance is defined in percentages and can make precise measurements challenging.
22-Apr-2024
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
The R&S®CMW wideband radio communication tester platform (R&S®CMW500, R&S®CMW270) uses high accuracy distance measurements (HADM) with phase based ranging (PBR) for a comprehensive and fully automated test solution to verify Bluetooth® Low Energy physical layer functionality
06-Sep-2023
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.
27-Apr-2023
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
The R&S®CMW500 and R&S®SMBV100B are the ideal team for motor vehicle type approval testing of your eCall and ERA-GLONASS cellular modems and their GNSS receivers in line with the EU2017/79 regulation.
02-May-2022
Automating measurement setups is advantageous for multiple reasons. It saves time in case of repeated measurements and in hazardous environments, instruments can be operated from a distance. The measurements are repeatable because they are always performed with a defined procedure, leading to higher test confidence.But in remote control applications, users often perceive synchronization and binary transfers as challenging. Therefore, this application note focuses on binary transfer of data to and from the instrument and shows code example to demonstrate the ease of use.
31-Mar-2022 | AN-No. 1SL381
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
RF system noise contributions define receiver capabilities and sensitivity. The noise figure measures how the critical components affect the signal.
28-Jan-2022
Software tool for fast and repeatable optimization of signal analyzer RF front-end settings
The signal conditioning in the RF front-end of signal analyzers is crucial to achieve the best performance with respect to image-suppression, noise-floor, dynamic range and other RF-key parameters.Precise signal levelling is especially important for complex measurements like Error-Vector-Magnitude (EVM). To minimize the measurement uncertainty from test system contributions over a wide range of different levels, the RF front-end needs to be adapted continuously according to the signal characteristics, signal power and frequency - ideally using an automatic levelling algorithm.This document describes the approach of a waveform specific, on-site characterization of the signal analyzer: For each waveform and frequency of interest, the instrument is evaluated in a first step. With this additional data, a fast and repeatable auto-levelling can be performed during the actual measurement.
24-Jan-2022 | AN-No. 1EF111
R&S®RTP, R&S®RTO, R&S®RTE, oscilloscopes, acquired waveform data, python How to work with acquired waveform data in Python using the R&S®RTP, R&S®RTO or R&S®RTE. Working with acquired waveform data in Python R&S®RTP, R&S®RTO, R&S®RTE, oscilloscopes, acquired waveform data, python How to work with acquired waveform data in Python using the R&S®RTP, R&S®RTO or R&S®RTE. Working with acquired waveform
12-Jan-2022
This application note demonstrates the use of the Measurement Receiver to calibrate the signal output level of a Signal Generator.Calibration in this application is a two-step process.► The absolute output level of the signal source, at a fixed level, is measured using a thermal power sensor (e.g. NRP50T), which in turn outputs its reading to the FSMR.► Output power calibration over a wider dynamic range (to lower power) is performed by connecting the FSMR to the signal source directly, and sweeping the power of the signal source.The FSMR offers a nominal total measurement uncertainty of <0.015 dB +/- 0.005 dB per 10dB step. At 1GHz, the power measurement range covers -152 dBm to +30 dBm. It is this intrinsic linearity, that the accuracy of the calibration relies upon.Absolute power measurement uncertainty, for the NRP50T thermal power sensor used in this Application Note, is 0.040 dB to 0.143 dB.This process may be repeated at multiple frequencies. Calibration values are automatically stored and managed by the FSMR. Measurement frequencies for calibrations are stored, will be automatically recalled by the FSMR, by re-selection of those frequencies.
31-Dec-2021 | AN-No. 1SL377
The R&S®FSMR3000 (hereinafter FSMR) is a three-in-one instrument incorporating a Measurement Receiver, a Signal and Spectrum Analyser, and a Phase Noise Analyser.This application note demonstrates the use of the FSMR, including the Cross-correlation option (R&S®FSMR3-B60), to measure the Phase Noise characteristics of a raw Signal Generator (R&®SMA100B).The Cross-correlation phase noise measurement improves sensitivity by 5 · log(n) dB, compared with measurements that do not use this option. For example, a measurement using 10 correlations, improves the phase noise floor by 5 dB.
31-Dec-2021 | AN-No. 1SL376
The application program of this application note provides a tool for cycling battery samples, using two-quadrant DC power supplies from Rohde & Schwarz. The batteries can be repeatedly charged and discharged while collecting information about open-circuit voltage, loaded voltage and internal resistance, depending on the charged and discharged capacity. The tool provides a variety of charts for displaying the collected data. It can be used for characterizing battery samples, as well as for creating battery models which can be used in the battery simulations of R&S®NGU201 and R&S®NGM200.This tool is meant for the use by knowledgeable experts. The application note does not provide instructions on how to properly charge and discharge batteries.
17-Dec-2021 | AN-No. 1GP130
Using VISA (Virtual Instrument Software Architecture) several interfaces allow communication between your computer and instruments. This application note describes the usage of both - R&S® VISA- NI VISA running on Microsoft Windows 10™ with the following connection types: ► USB VCP (Virtual Com Port), also called USB CDC (Communications Device Class) ► USB TMC (Test and Measurement Class)► Ethernet Raw Port Socket► Ethernet in general e.g. VXI11 or HislipAll the examples are shown using the R&S® HMC8042 unless otherwise stated. There may be some difference when integrating other devices. As example some interface types are not available on every unit.This application note does not claim to be complete. All information has been compiled with care. However, errors can’t be ruled out.
28-Oct-2021 | AN-No. 1SL374
R&S®Server-Based Testing helps reduce test times for workloads that can be parallelized. 5G New Radio (5G NR) multicarrier signals are an ideal workload because each component carrier can be analyzed independently and in parallel. In an example EVM measurement, scenario test times are reduced significantly even when receiving I/Q data from just a single instrument.
13-Sep-2021
Linking EDA design simulation and hardware testing to enable an easy, straightforward process flow and first-pass design.
16-Aug-2021
In civil aviation, instrument landing system (ILS) transmitters use antenna arrays to provide guidance to approaching aircraft. ILS performance strongly depends on the precise alignment of the magnitude and phase of each element in an antenna array. The R&S®ZNH handheld vector network analyzer with a built-in source allows fast, convenient on-site measurements on the ILS antenna system.
09-Aug-2021
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.
19-Jul-2021
Vector network analyzers are the most accurate instruments in the microwave engineer’s lab. The R&S®ZNA takes accuracy to a new level. Not only is the instrument extremely precise, but now it also calculates and displays the measurement uncertainty right on the screen as the device under test is being measured.
19-Jul-2021
Using R&S®RTP high-performance oscilloscopes and R&S®VSE-K6A phased array measurement option
12-Jul-2021
The verification of emissions according to EN or FCC standards is mandatory to avoid any interference with existing users. Besides the common emission tests with measurement bandwidth up to 1 MHz and mean power measurements, most regulations also require to test peak transmission power within a 50 MHz bandwidth to avoid interference with any existing wideband applications, for example radar receivers. This application note provides information how to perform spectral emission measurements on UWB signals with spectrum analyzers using wide bandwidth RBW filters, and explains the capabilities and the limiting factors of the Rohde & Schwarz FSW signal and spectrum analyzer to perform this measurement. The next sections will give further details.
28-Jun-2021 | AN-No. 1EF109
Rohde & Schwarz presents a customizable solution for testing barometric performance to ensure z-axis accuracy in line with FCC regulations.
24-Jun-2021
Primer
A power sensor is a fundamental measurement tool in RF engineering. However, today's marketplace is filled with myriad choices, and many are making bold claims about attributes such as measurement speed and readings per second. As a result, it can be difficult to cut through the hyperbole and determine which sensor will actually meet the requirements of a specific measurement.This primer outlines the basics of RF power sensors and highlights a few key characteristics that will help you select the best one for each application. The narrative has three parts. First, we focus on choosing the right type of sensor: multipath, wideband, average power and thermal can satisfy slightly different measurement needs. The second section covers the five major attributes of sensor performance, and what to look for relative to your requirements. Finally, we outline three ways to integrate a sensor into your measurement application.
26-May-2021
The test case wizard enables the signal generator to set up all required parameters for conformance testing of 5G NR base stations in no time with just a few clicks.
25-May-2021
The UWB (Ultra-Wide Band) technology is a low power wide-band technology specified for device to device communication.It is an optimal RF positioning technology that enables accurate and secure peerto-peer distance measurement between mobile devices with robust resistance to interference while consuming very low energy and coexisting well with other radio communication systems.This application note describes how to use the UWB measurement functionality provided by R&S®CMP200 radio communication tester to perform HRP UWB PHY measurements for R&D and production purposes.
19-May-2021 | AN-No. GFM362
Synthetic aperture radar (SAR) uses radar wavelengths for airborne or spaceborne ground mapping. The resolution of the SAR ground map depends on the range and cross-range SAR processing resolution. Cross-range resolution is determined by integrating pulses along a flight path for a period of time to create a synthetic aperture. Longer synthetic apertures result in finer cross-range resolution. Range resolution is achieved by radar waveform bandwidth in the form of a linear frequency modulated (LFM) chirp. Wider bandwidth enables finer range resolution.
16-Apr-2021
Analyzing high speed datacom interfaces is an important task and ensures signal integrity. One major challenge of this analysis is the connection between the physical interface and the oscilloscope, as most of the datacom interfaces do not provide test connections suitable for RF. A test fixture is required as a bridge between the high speed datacom IF and the RF connector of the oscilloscope, but this will affect the signal integrity measurement. The R&S®RTP and R&S®RTO2000 oscilloscopes with the advanced jitter option can analyze and separate jitter contributions. Additionally, the option can evaluate the impact of test fixtures and traces inherently and give the user a good understanding of the impact of their test setup.
31-Mar-2021
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
Source measure units R&S®NGU401 and R&S®NGU201 are capable of precise current measurements from sub-microampere up to ampere. This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep. Subsequently the application program determines the voltage and current value for each sweep step and plots the results in an I-V curve .The tool can be utilized to characterize all kinds of two-pole devices like diodes, LEDs and solar panels.This application note can also be used in connection with DC power supplies R&S®NGM201 and R&S®NGM202.
15-Feb-2021 | AN-No. 1GP129