Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1104 Results
ZVR is a vector network analyzer equipped with selective input channels for determining phase relations. Thus a wide dynamic range can be obtained. For measurements on frequency-converting DUTs (output frequency not identical to input frequency), the generator and receiver frequency ranges can be separately set. For measurements on DUTs using a built-in conversion oscillator, as is the case here, the conversion frequency must be exactly known so that the receiver can be accurately tuned to the respective output frequency. The maximum receiving bandwidth is 26.5 kHz. When a wide dynamic range is required, this bandwidth has to be reduced with the consequence that the requirement for the DUT output frequency and the ZVR receive frequency to be in agreement will be greater.
04-Aug-1998 | AN-No. 1EZ31
This application note describes Methods of Implementations (MOI) for precise, fast and error-free compliance testing of high-speed backplanes and direct attach copper cables (DAC) according to IEEE 802.3bj, IEEE 802.3by, IEEE 802.3cd and IEEE 802.3ck, based on 25 Gb/s, 50 Gb/s and 100 Gb/s signaling per lane with vector network analyzers from Rohde & Schwarz.
07-Apr-2021 | AN-No. GFM356
This Application Note describes the internal transfer of ZVR measurement data in Excel, carried out on the PC option of the ZVR, and the evaluation of the data in Excel tables. To start the data transfers, macros are implemented under Excel.
28-Jul-1998 | AN-No. 1EZ39
Simulation can be a big time-saver when designing EMI filters for DC/DC converters. Power supply control chip vendors offer various filter design tools that provide reasonable design choices for filter simulation before any hardware prototype is available. However, simulated results can differ significantly for different tools if simulated models are not accurate or do not cover all the relevant components. Performing a hardware measurement to evaluate the effectiveness of a simulated EMI filter is therefore indispensable.
21-Sep-2021
GSM Adaptive Multi-Rate (AMR) tests can be performed by using the R&S CMU300 as of software version V3.65. This document describes the scope of functions of the AMR Testing R&S CMU-K37 software expansion option.
26-Jul-2005 | AN-No. 1CM59
combinational tests, terminal equipment, test system, electrical test, telecommunicaitons, open test platform, CompactTSVP, DUT, acoustic characteristics, GTSL, diver, ETSI Combinational tests for telephone terminal equipment Combinational tests for telephone terminal equipment combinational tests, terminal equipment, test system, electrical test, telecommunicaitons, open test platform, CompactTSVP
26-Apr-2006
With a Rohde & Schwarz oscilloscope
19-Jun-2019
This application note describes how to use the advanced interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S004
DECT standard ETS 300 175-2 prescribes among others measurement of the transmit power and the unwanted power in adjacent channels. Following a brief introduction into DECT, this Application Note describes the standard-conforming measurement of the normal transmit power NTP and the unwanted adjacent-channel power ACP using a spectrum analyzer from the FSE family ( firmware version 1.63 and higher). Option FSE-B7 (Vector Signal Analyzer) is required for measuring the normal transmit power NTP since the signal must be demodulated for this measurement. Due to the wide dynamic range of FSEA20 and FSEA30, the adjacent channel power ACP can be measured without bandpass filters suppressing the transmit channel. Option FSE-B7 is not required for measuring the adjacent-channel power.
28-Apr-1998 | AN-No. 1EF42
This Application Note describes the method to perform a valid Access Probe Power and Standby Power measurement for CDMA2000® 1xRTT and 1xEV-DO by using the R&S CMW500’s GPRF analyzer list mode functionality.
25-May-2012 | AN-No. 1CM99
This White Paper provides a more detailed view on radar waveforms for Aerospace and Defence and commercial radar systems. Waveforms such as pulse and pulse-Doppler signal, continuous wave and frequency shift keying waveforms are described. It also shows continuous waveform trends designed for specific needs and application differences of continuous wave radar compared to pulse radar systems.
31-Aug-2015 | AN-No. 1MA239
The present R&S®SMW-K503/-K504 Interface Control Document contains information on- the R&S descriptor word format, including pulse descriptor words and timed control descriptor words in basic and expert mode- Timing requirements and limitations of the real-time control interface- Properties of the ADV DATA/CTRL network interfaceIt is intended for use by customers using descriptor words to control the R&S®SMW200A in real-time. The interface control document specifies the interface between the customers hardware used for provision of descriptor words and the R&S®SMW200A ADV DATA/CTRL interface. Additional information on descriptor word processing inside the R&S®SMW200A is provided.
25-Aug-2021 | AN-No. 1GP133
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
The Bluetooth® wireless standard has been an unparalleled success. It has found its way into virtually all smartphones, PCs, cars, entertainment hardware and wearables. Bluetooth SIG reports that more than 8 billion devices are currently in use. Bluetooth supports Internet of Things (IoT) technologies and direction finding methods, making it a sure bet for the future as well.This white paper summarizes the various Bluetooth technologies with a focus on the physical layer in line with core specification version 5.1.
05-Jun-2019 | AN-No. 1MA108
TETRA, the TErrestrial Trunked RAdio, is the professional mobile radio standard (PMR) used world wide by governmental safety and security authorities and organizations, as well as by private utilities from energy suppliers through to transport. Rohde & Schwarz provide test instruments idealy suited for both the development and production of TETRA base stations and user equipment, as well as for network planning, network coverage and quality of service, network monitoring and optimization, maintenance, and service. This Application Note shows examples for measurements with R&S instruments covering the entire range of TETRA test requirements.
26-Apr-2013 | AN-No. 1MA189
All models of the receiver family ESXS are equipped with a remote-control interface to IEC 625-2 (IEEE 488.2). Via this bus almost all instrument settings can be effected, measurements triggered and test results read in by the PC.
18-Jan-2002 | AN-No. 1EE05
TS-EMF2 TS-EMF TRD Conversion TRD Conversion TS-EMF2 TS-EMF TRD Conversion Related products
25-Jan-2007 | AN-No. TS-EMF2
The voltage standing wave ratio (VSWR) is one of the parameters in RF systems that measures the impedance mismatch. Under ideal conditions, when the load is perfectly matched to the source, the VSWR will be 1. A mismatch in the system causes reflections that will increase the VSWR and lead to losses in transmission. Although most RF components are typically designed and specified with a characteristic impedance of 50 Ω , applications and system components for cable television are designed and specified with a characteristic impedance of 75 Ω . This application note describes the measurement procedure for VSWR measurements in 75 Ω systems using the R&S®FSH3-TV handheld TV analyzer.
01-Mar-2008 | AN-No. 7BM72
Spectrum and network analyzers are capable of measuring large amounts of data that require complex mathematical processing; MATLAB is a powerful tool for such operations. This application note describes how instruments can be controlled directly from MATLAB scripts and how measurement data can be imported into MATLAB. Only 32-bit MATLAB is supported.
24-Sep-2007 | AN-No. 1EF46
With all these new flexibilities introduced with 5G, the radio access has become more complex to understand and analyze. More network interfaces and RAN configuration parameters have to be managed and the RAN and in particular the connection control, mobility and measurement reporting are decisive for the network performance. It will be vital for the system experts and radio engineers to gain knowledge and evolve their methods and tools to facilitate the work to optimize and troubleshoot 5G and 4G RAN performance. Thus, tools are needed that allow for easier understanding of the message flows in the radio protocols. The R&S®ROMES4 KPIs and Smart Events will help doing the work much easier and quicker. They are defined for a key set of LTE, EN-DC and NR RRC connection control and mobility procedures where the performance is crucial to achieve high quality network performance. Trouble shooting problematic cases and optimization of RAN protocols are key drivers to improve the mobile network performance with R&S®ROMES4.
28-Jun-2022 | AN-No. 8NT06
The R&S®CMU200 provides the signals required for 2nd order intermodulation (IM2) performance verification for WCDMA / CDMA2000® chipsets with zero IF design.This application note is a guide to configure the R&S®CMU200 for such an application.
16-Dec-2004 | AN-No. 1CM54
Secure interconnection of ATC voice networks
11-Mar-2019
In car-to-car communications scenarios, fading is always present and has an enormous impact on the received signal. The R&S®SMW200A vector signal generator lets you perform the most accurate and reproducible receiver tests under car-to-car fading conditions. The required car-to-car radio channel models have been extracted from real field trials and specified by the CAR 2 CAR Communication Consortium. Now it is possible to verify receiver performance under controlled conditions in the lab.
06-Nov-2017
Radar technology is essential for state-of-the art and future vehicles on the path to full autonomous driving. Radar sensors deliver critical information about the surrounding traffic environment or monitor the interior of the vehicle. As safety-relevant parts, radar sensors must adhere to specifications and regulations.
12-Dec-2022
Connecting simulation and measurements on physical devices
This application note is based on collaborative work between MathWorks® and Rohde & Schwarz. The focus is on linearization of a non-linear device, in our case the RF power amplifier. It is shown how simulation and the integrated functions of the Rohde & Schwarz instruments R&S®SMW200A and R&S®FSW work hand-in-hand with the simulation capabilities from MathWorks in MATLAB / Simulink. The goal is to provide a toolset to enable proper modeling and linearization approaches to optimize and verify the behavior of the power amplifier when used with complex wideband signals as used in 5G NR or latest satellite links.The application note brings code examples and an exemplary block set for MATLAB / Simulink to provide an easy start to replicate and use the described procedure.
05-Aug-2021 | AN-No. 1SL371
Getting EMI emissions under control is one of those tasks that R&D engineers do not enjoy doing . EMI must often be taken into consideration as early as the design phase, particularly in the case of power electronics systems with increasing switching speeds of wideband gap semiconductors. While EMI receivers or spectrum analyzers are always the preferred choice for these measurements, they are often not available as standard measurement equipment in the R&D lab. To allow optimization early on in the R&D lab, Rohde & Schwarz provides a free tool to simplify conducted emissions debugging using oscilloscopes.
27-Sep-2021 | AN-No. 1SL372
Application Note 1MA68 has been replaced by .
10-Dec-2008 | AN-No. 1MA68
This document provides an introduction to SDR as used for military radios and presents the relevant T&M solutions offered by Rohde & Schwarz.
15-Sep-2012 | AN-No. 1MA206
The CMD 57/59 output level for BER measurement can be calibrated to high accuracy to match GSM 11.21, (with modulated signals and adjacent timeslots + 50 dB above the used timeslot) using a simple test setup containing an NRVD power meter and an FSE spectrum analyzer.
10-Mar-2000 | AN-No. 1MA24