R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front low R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, back view R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view

Key facts

  • Max. output power: 800 W
  • Max. voltage per channel: 32 V or 64 V
  • Max. current per channel: 10 A or 20 A
  • Up to 250 V or 80 A in series or parallel operation
  • Large touch display

Starting at AUD4,840

Boost your efficiency with quadcore power

The R&S®NGP800 DC power supply series, comprising five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A.

Features & benefits

Touch display

High-resolution touch display for easy operation

The large high-resolution touch display makes operation easy. Quickly navigate through the menus to access all functions and settings. Enter values much faster using the virtual keyboard instead of turning the knob. The home screen gives you a clear overview of all your channels. Each channel can be selected for a more detailed view with a wide variety of additional information, such as statistics and icons indicating the status of set protection or special functions.

The home screen gives a clear overview of all channels
Open Lightbox

The home screen gives a clear overview of all channels

FlexPower

Get the maximum power at various operating points

Unlike with single range power supplies, you can generate variable voltage and current combinations within the overall power limit of 200 W per channel. This technology makes your power supply a lot more versatile, covering a wider range of applications.

V/I-curves for 32 V output and 64 V output
Open Lightbox

V/I-curves for 32 V output and 64 V output

Parallel & serial operation

Up to 250 V or 80 A

In case your application requires more voltage or current, connect the outputs in series or parallel and get up to 250 V (R&S®NGP824) or 80 A ( R&S®NGP804) - giving you the flexibility you always asked for. Using the tracking function, voltage and current are adjusted on all selected channels simultaneously.

Parallel & serial operation
Open Lightbox

Parallel & serial operation

Built-in measurements

Integrated statistics

The built-in measurements reduce the need for an external multimeter and simplify the setup. The seperate voltage and current meters on each output give a resolution of 1 mV and 0.5 mA over the full output range of 64 V and 20 A, respectively. Integrated statistics show the min, avg and max values for power, voltage and current as well as an energy count.

One-channel-view with details and integrated statistics
Open Lightbox

One-channel-view with details and integrated statistics

Data Logging

Key to long-term monitoring

Logging data is key to long-term monitoring, reviewing test setups and repeating test conditions when analyzing power behaviors or optimizing power consumption. The R&S®NGP800 power supplies simultaneously log voltage and current measurements over time on all outputs. You can easily export the timestamped data as a .CSV file for reports and documentation.

Logging setup dialog
Open Lightbox

Logging setup dialog

Arbitrary function

QuickArb

Emulate the normal behaviors of your power subsystem early in the design process and simulate power problems for DUT design verification. The QuickArb function lets you generate voltages that vary over time and current sequences of output changes with dwell times down to 1 ms. Load up to eight subgroup files into one sequence to create complex patterns.

Fast programming of sequences with the Arb Editor
Open Lightbox

Fast programming of sequences with the Arb Editor

Available models

Available models
Models
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at

R&S®NGP802

Order number 5601.4007.05

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
Starting at

R&S®NGP804

Order number 5601.4007.02

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
Starting at

R&S®NGP814

Order number 5601.4007.04

Number of output channels
4
Max. output power
800 W
Output voltage per channel
Ch 1, Ch 2: 0 V to 32 V
Ch 3, Ch 4: 0 V to 64 V
Output current per channel
Ch 1, Ch 2: 0 A to 20 A
Ch 3, Ch 4: 0 A to 10 A
Starting at

R&S®NGP822

Order number 5601.4007.06

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
Starting at

R&S®NGP824

Order number 5601.4007.03

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
Starting at
Specifications
Electrical specifications
Number of output channels 2 or 4
Total output power max. 400 W/800 W
Maximum output power per channel 200 W
Output voltage per channel 0 V to 32 V (32 V channels)
0 V to 64 V (64 V channels)
Maximum output current per channel 20 A (32 V channels)
10 A (64 V channels)
Voltage ripple and noise (20 Hz to 20 MHz) < 3 mV (RMS)
< 30 mV (Vpp) (meas.)
Current ripple and noise (20 Hz to 20 MHz) < 3.5 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 400 μs (meas.)
Programming resolution voltage 1 mV
Programming resolution current 0.5 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current 0.5 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 5 mV (32 V channels)
< 0.05 % + 10 mV (64 V channels)
Readback accuracy current ±(% of output + offset) < 0.1 % + 20 mA (32 V channels)
< 0.1 % + 10 mA (64 V channels)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode
Output sequencing
Trigger input/output
Arbitrary function ● (QuickArb)
Analog/modulation interface
Data logging ● (standard mode)
Display and interfaces
Display TFT 5" 800 pixel × 480 pixel WVGA touch
Rear panel connections 8-pin connector block per 2 channels
Remote control interfaces: standard USB, LAN
Remote control interfaces: optional WLAN, IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 362 mm × 100 mm × 451 mm
Weight 7.5 kg/8.0 kg
Rack installation R&S®ZZA-GE23 option

Available options

General
Product
Description
R&S®NG-B105

Order number 5601.6000.02

Description

IEEE-488 (GPIB) interface

General analysis
Product
Description
R&S®NGP-K102

Order number 5601.6400.03

Description

Wireless LAN remote control

R&S®NGP-K103

Order number 5601.6300.03

Description

Digital trigger I/O

R&S®NGP-K107

Order number 5601.6200.03

Description

Analog input

General accessories
Product
Description
R&S®ZZA-GE23

Order number 5601.4059.02

Description

19" rack adapter, 2 HU

Video overview

Boost your efficiency with quadcore power

With four independent outputs, each supplying up to 64 V or 20A, the new NGP800 power supplies will boost the efficiency in any lab.

13-Feb-2020

DC Power supplies promotion

DC Power supplies & Power analyzer promotion

Save more than 20% on fully equipped power analyzer, DC power supplies and power meter from Rohde & Schwarz, now through August 31st, 2021

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

I want to receive information from Rohde & Schwarz via

Marketing permission

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.