R&S®EPL EMI test receiver

Mix, match and upgrade for your EMI testing.

R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL1007 EMI test receiver, front low R&S®EPL EMI test receiver video R&S®EPL1007 EMI test receiver, front high R&S®EPL1007 EMI test receiver, side view R&S®EPL1007 EMI test receiver, side view, feet R&S®EPL1007 EMI test receiver, back high R&S®EPL1000 EMI test receiver, front low

Key facts

  • Testing from 5 kHz up to 7.125 GHz
  • Precompliance and compliance testing
  • Flexible option concept – buy what you need, upgrade at any time
  • Fast time domain scan
  • Battery operation for mains independent use

Perfect for quick and precise EMI measurements

For precompliance and compliance applications from 5 kHz up to 7.125 GHz

The R&S®EPL1000 is specially designed for conducted measurements up to 30 MHz. Even the base unit offers time domain scan and preselection with preamplifier and fully complies with CISPR 16-1-1. For flexible pricing, these features are optionally available for the R&S®EPL1001 and R&S®EPL1007 which measure up to 1 GHz/7.125 GHz. All models automatically perform EMI measurements over several individually defined frequency ranges. Results are easily saved and printed. The R&S®EPL also offers in-depth analysis functions including a real-time spectrogram and four-channel click rate analysis. Battery operation, 12 V to 24 V DC input, a carrying bag and other extras enable very flexible deployment of the R&S®EPL.

Features & benefits

For all use cases

Up to CISPR 16-1-1 compliance

The R&S®EPL can be used both during the development phase and for certification. Provided RF and CISPR 16-1-1 relevant features include:

  • Hardware protection and attenuation of strong signals
  • Automatic use of full dynamic range and overload handling 
  • EMI bandwidths and detectors
With R&S®EPL1-B2 (included in R&S®EPL1000):
  • Improved measurement of broadband interferers and short pulses
  • Measurement of small signals
With R&S®EPL1-B1611 (included in R&S®EPL1000):
  • Full CISPR 16-1-1 compliance

Configuration and display of RF signal handling
Open Lightbox

Configuration and display of RF signal handling

Time domain scan

Fast measurement with time domain scan

Using RBWs as defined by CISPR, the R&S®EPL can measure an entire CISPR band A or B in a single measurement. Frequency ranges above 30 MHz are measured automatically in multiple steps of 20 MHz using CISPR band associated RBWs. Up to three traces can be activated with different detectors, including CISPR detectors. This enables fast standard-compliant EMI measurements directly with the detector required by the standard.

Illustration of the TDS segment width
Open Lightbox

Illustration of the TDS segment width

Convenient measurements

Strong features simplify the execution and documentation of EMI measurements

  • Automatic measurement of multiple frequency segments with individual settings (scan table)
  • Automated sequence of preview measurement, peak search and final measurement
  • Limit line display and checking to easily evaluate measurement results
  • Report generation to easily record, document and exchange results
  • Transducer factors to include characteristics of additional components used

Automatic measurement example
Open Lightbox

Automatic measurement example

Measurement of A and B bands for neutral and live lines.

EMI analysis

The extensive analysis features include

  • Four-channel click rate analysis
  • Bar graph – level at a frequency
  • Real-time spectrogram – level versus frequency and time
  • Zero span – level at a frequency versus time
  • IF analysis
  • AM/FM output
  • Spectrum analysis functions

Measurement example with spectrogram
Open Lightbox

Measurement example with spectrogram

Visualization of different EUT operating modes

Available models

Available models
Models
Frequency range

R&S®EPL1000

Order number 1350.4444.10

Frequency range
5 kHz to 30 MHz

R&S®EPL1001

Order number 1350.4444.11

Frequency range
5 kHz to 1 GHz; upgradeable to 7.125 GHz

R&S®EPL1007

Order number 1350.4444.17

Frequency range
5 kHz to 7.125 GHz

Available options

Hardware options
Product
Description
R&S®EPL1-B2

Order number 1350.4015.02

Description

Preselection with preamplifier

R&S®FPL1-B4

Order number 1323.1902.02

Description

OCXO accurate reference frequency

High precision frequency reference

R&S®FPL1-B10

Order number 1323.1890.02

Description

GPIB interface

Additional interface for remote control by GPIB, plug-in unit

R&S®FPL1-B30

Order number 1323.1877.02

Description

DC Power supply for 12/24 V supply

R&S®FPL1-B31

Order number 1323.1725.02

Description

Li-Ion battery pack

R&S®EPL1-B91

Order number 1350.4073.02

Description

Internal generator 5 kHz to 30 MHz

Software options
Product
Description
R&S®EPL1-B9

Order number 1350.4467.02

Description

Internal generator 5 kHz to 1 GHz

R&S®EPL1-B9

Order number 1350.4044.02

Description

Internal generator 5 kHz to 7.125 GHz

R&S®EPL1-B22

Order number 1350.4480.02

Description

Low-noise preamplifier 2 MHz to 1 GHz/7.125 GHz

R&S®EPL1-B1611

Order number 1350.4515.02

Description

CISPR 16-1-1 compliance

R&S®EPL1-K53

Order number 1350.4050.02

Description

Time domain scan

R&S®EPL1-K55E

Order number 1350.4473.02

Description

Real-time spectrogram

R&S®EPL1-K56

Order number 1350.4067.02

Description

IF analysis

R&S®EPL1-K59

Order number 1350.4509.02

Description

4-channel click rate analyzer

CISPR 14-1 ed. 6 and ed. 7 compliant software for 4 channel simultaneous gapless measurement for up to four hours.

R&S®FPL1-K7

Order number 1323.1731.02

Description

AM/FM/PM analog modulation analysis

Modulation analysis for analog (AM, FM, PM) modulated single carrier signals
(for use with the R&S®ZNL, the R&S®ZNLx-B1 is required )

R&S®EPL1-B7125

Order number 1350.4021.02

Description

Frequency upgrade 1 GHz to 7.125 GHz, only for delivered R&S®EPL1001

Accessories
Product
Description
R&S®EPL1-Z1

Order number 1350.4296.02

Description

Protective hard cover

R&S®EPL1-Z2

Order number 1350.4309.02

Description

Soft carrying bag for R&S®EPL1000

R&S®EPL1-Z2

Order number 1353.6431.02

Description

Soft carrying bag for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-Z3

Order number 1350.4315.02

Description

H-style shoulder harness (requires R&S®EPL1-Z2 option)

R&S®FPL1-Z4

Order number 1323.1677.02

Description

Spare battery pack

R&S®EPL1-Z6

Order number 1350.4321.02

Description

19" rackmount kit for R&S®EPL1000

R&S®EPL1-Z6

Order number 1353.6377.02

Description

19" rackmount kit for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-B19

Order number 1350.4450.02

Description

Replacement SSD including controller unit

R&S®FSV-B34

Order number 1321.3950.02

Description

Charger for R&S®FSV-B32 lithium-ion battery pack

R&S®EZ-21

Order number 1107.2087.03

Description

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Order number 1107.2087.10

Description

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®DCV-2

Order number 0240.2193.09

Description

Documentation of calibration values

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.