Key facts
- Testing from 5 kHz up to 7.125 GHz
- Precompliance and compliance testing
- Flexible option concept – buy what you need, upgrade at any time
- Fast time domain scan
- Battery operation for mains independent use
Key facts
For precompliance and compliance applications from 5 kHz up to 7.125 GHz
The R&S®EPL1000 is specially designed for conducted measurements up to 30 MHz. Even the base unit offers time domain scan and preselection with preamplifier and fully complies with CISPR 16-1-1. For flexible pricing, these features are optionally available for the R&S®EPL1001 and R&S®EPL1007 which measure up to 1 GHz/7.125 GHz. All models automatically perform EMI measurements over several individually defined frequency ranges. Results are easily saved and printed. The R&S®EPL also offers in-depth analysis functions including a real-time spectrogram and four-channel click rate analysis. Battery operation, 12 V to 24 V DC input, a carrying bag and other extras enable very flexible deployment of the R&S®EPL.
Quick links
Up to CISPR 16-1-1 compliance
The R&S®EPL can be used both during the development phase and for certification. Provided RF and CISPR 16-1-1 relevant features include:
Configuration and display of RF signal handling
Fast measurement with time domain scan
Using RBWs as defined by CISPR, the R&S®EPL can measure an entire CISPR band A or B in a single measurement. Frequency ranges above 30 MHz are measured automatically in multiple steps of 20 MHz using CISPR band associated RBWs. Up to three traces can be activated with different detectors, including CISPR detectors. This enables fast standard-compliant EMI measurements directly with the detector required by the standard.
Illustration of the TDS segment width
Strong features simplify the execution and documentation of EMI measurements
Automatic measurement example
Measurement of A and B bands for neutral and live lines.
The extensive analysis features include
Measurement example with spectrogram
Visualization of different EUT operating modes
Order number 1350.4015.02
Preselection with preamplifier
Order number 1323.1902.02
OCXO accurate reference frequency
High precision frequency reference
Order number 1323.1890.02
GPIB interface
Additional interface for remote control by GPIB, plug-in unit
Order number 1323.1877.02
DC Power supply for 12/24 V supply
Order number 1323.1725.02
Li-Ion battery pack
Order number 1350.4073.02
Internal generator 5 kHz to 30 MHz
Order number 1350.4467.02
Internal generator 5 kHz to 1 GHz
Order number 1350.4044.02
Internal generator 5 kHz to 7.125 GHz
Order number 1350.4480.02
Low-noise preamplifier 2 MHz to 1 GHz/7.125 GHz
Order number 1350.4515.02
CISPR 16-1-1 compliance
Order number 1350.4050.02
Time domain scan
Order number 1350.4473.02
Real-time spectrogram
Order number 1350.4067.02
IF analysis
Order number 1350.4509.02
4-channel click rate analyzer
CISPR 14-1 ed. 6 and ed. 7 compliant software for 4 channel simultaneous gapless measurement for up to four hours.
Order number 1323.1731.02
AM/FM/PM analog modulation analysis
Modulation analysis for analog (AM, FM, PM) modulated single carrier signals
(for use with the R&S®ZNL, the R&S®ZNLx-B1 is required )
Order number 1350.4021.02
Frequency upgrade 1 GHz to 7.125 GHz, only for delivered R&S®EPL1001
Order number 1350.4296.02
Protective hard cover
Order number 1350.4309.02
Soft carrying bag for R&S®EPL1000
Order number 1353.6431.02
Soft carrying bag for R&S®EPL1001/R&S®EPL1007
Order number 1350.4315.02
H-style shoulder harness (requires R&S®EPL1-Z2 option)
Order number 1323.1677.02
Spare battery pack
Order number 1350.4321.02
19" rackmount kit for R&S®EPL1000
Order number 1353.6377.02
19" rackmount kit for R&S®EPL1001/R&S®EPL1007
Order number 1350.4450.02
Replacement SSD including controller unit
Order number 1321.3950.02
Charger for R&S®FSV-B32 lithium-ion battery pack
Order number 1107.2087.03
Control Cable, 3 m
from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200
Order number 1107.2087.10
Control Cable, 10 m
from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200
Order number 0240.2193.09
Documentation of calibration values
Related products
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes
1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).
2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.
3. Participation is free of charge and not dependent on the purchase of goods or services.
4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.
5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:
Prize: 1x R&S®RTB2000 Digital Oscilloscope
6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.
7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.
8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.
9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.
10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.
11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.
12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.
13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.