Why Nyquist and Shannon do not stand in the way of precise RMS power measurements

Power measurements require precise signal sampling that fully determines the voltage and current waveform. Despite undersampling, the RMS power can be measured accurately.

R&S®NPA power analyzer series and ZES ZIMMER LMG600 power analyzer series
R&S®NPA power analyzer series (top) and ZES ZIMMER LMG600 power analyzer series (below)
Open Lightbox

The challenge

What’s the point of having a power analyzer with 10 MHz analog bandwidth and a sample rate of 1.2 Msample/s?

Does the Nyquist-Shannon sampling theorem not tell us that the sample rate must be at least twice the signal frequency? Would that not limit our ability to measure the power to a maximum frequency of 600 kHz?

The answer: No, it wouldn’t. Why is that? In order to understand, we first need to take a detailed look at what the sampling theorem actually states before proceeding.

Claude Shannon 1) formulated it thus:

Definition of complete determination

As we already might suspect, everything hinges on the definition of “completely determined”. Do we need to “completely determine” a signal in order to obtain RMS power? No, we don’t. Active power contains much less information about a signal than its complete determination. If we completely determine a signal by sampling, we are able to reconstruct the signal in a way such that our reconstruction cannot be distinguished from the original.

It is obvious that having a reliable measurement of a given signal’s active power does not allow us to reconstruct that signal – there are an unlimited number of different signals that end up having the same active power value nevertheless. Active power contains much less information than its complete determination. Sampling a signal at a lower rate than required to completely determine it is known as undersampling. In the next step, we are going to look at how sampling a signal for active power measurement works and how undersampling would or would not affect the results.

The sampling theorem 2):

“If a function f(t) contains no frequencies higher than W cps, it is completely determined by giving its ordinates at a series of points spaced ½ W seconds apart.”

The impact of undersampling

This is how active power is defined (we are still in the analog domain, looking at the signal prior to digitization):

Digital sampling is turning the continuous u(t) · i(t) signal into a sequence of discrete sample values, with P simply becoming the average of the individual sample values:

Signal sampling with 17 samples per period
Signal sampling with 17 samples per period
Open Lightbox
Signal sampling with 1/2 of the sample rate from the top graph
Signal sampling with 1/2 of the sample rate from the top graph
Open Lightbox
Signal sampling with 1/3 of the sample rate from the top graph
Signal sampling with 1/3 of the sample rate from the top graph
Open Lightbox

It follows from the commutative property of addition that the order of summands does not matter for the value of the sum. In other words: The order of the sample values does not matter for their average. Let us look at a graphical example to see what the variation of sample rates means in practice:

The result

The first example shows a sampling process with 17 data points per signal period, the second example uses half that sample rate, and in the third one the rate is reduced to one third. Although the resolution is diminished when using fewer points per period, the average and thus the resulting active power (if the sampled signal is u(t) · i(t)) stay the same, as long as enough signal periods get sampled. As long as the signal frequency is not an exact multiple of the sample rate 3), we will eventually “collect” the same number of different points per signal period as we would have if we were sampling a period using a higher sample rate, albeit in a different order. Even if we only had one sample per signal period (which obviously would not allow us to reconstruct signal shape), we would only need 17 cycles to capture 17 different data points. At a signal frequency of e.g. 5 MHz, even a 100 kHz sample rate would get us 106 data points to average over every single second.

1) In all fairness: Although the sampling theorem is typically named after Nyquist and Shannon, it had already been discovered by Vladimir Kotelnikov in 1933

2) Communication in the Presence of Noise, Proceedings of the Institute of Radio Engineers (IRE) (Volume: 37, Issue: 1, Jan. 1949, pp. 10-21)

3) Instrument manufacturers avoid this by picking extremely odd sample rates.

Related solutions

Demander des informations

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.
For service/support requests, please go here to log in or register.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.