Key Facts

  • Max. output power: 100 W
  • Max. voltage per channel: 32 V
  • Max. current per channel: 3 A, 5 A or 10 A
  • Galvanically isolated, floating and short-circuit proof outputs
  • Intuitive, price-transparent online product configurator
  • R&S®Essentials

Compact and easy to use

R&S®NGC100 DC power supplies are very energy efficient, remaining cool and quiet, even at maximum load. Practical interfaces and connectors make work quick and convenient while special applications have comfort functions. One, two, or three channels – a wide range of functions and fundamental specifications make R&S®NGC100 DC power supplies ideal for:
-Development labs
-Industrial environments
-Manufacturing
-Education
You can now use the new online configurator to quickly design your R&S®NGC100 DC power supply with full price transparency. Get your request processed in no time by the authorized distribution partner of your choice.

Caractéristiques & avantages

Maximum output power at various operating points

With FlexPower

Get maximum power at various operating points. Unlike single-range power supplies, variable voltage and current combinations can be generated within an overall power limit.

Emulate real-world scenarios

With EasyArb 

Generate complex time varying output voltage or current sequences with the EasyArb function to emulate normal power subsystem behavior early in the design process or simulate power problems for DUT design verification. The EasyArb function lets you generate time varying output voltage and current sequences with dwell times down to 10 ms.

Log measurement values

Every millisecond

Logging data is vital to long-term monitoring, reviewing test setups and repeating test conditions to analyze power behavior or optimize power consumption. R&S®NGC100 power supplies simultaneously log voltage and current measurements over time on all outputs with a maximum acquisition rate of 1000 samples/s. Easily export the time stamped data as a CSV file for analysis, reports and documentation.

Higher current and voltage levels

With parallel and serial operation

Each output in the 2-channel and 3-channel models is completely isolated for maximum flexibility. Use the channels independently or combine them in series to increase the maximum voltage to 96 V, or in parallel for up to 10 A of current. The full galvanic isolation means that channels can be connected to supply balanced circuits without any need to think about grounding.

Up to 96 V with the R&S®NGC103 power supply
Open Lightbox

Up to 96 V with the R&S®NGC103 power supply

Control inrush current

With EasyRamp

Some test setups require a continuous rise in supply voltage instead of a rapid jump to control inrush currents. Increase output voltage continuously within 10 ms to 10 s with the EasyRamp function.

Create power up sequences

With output delay

Turn on each channel individually with a delay to meet requirements for modern micro controllers with multiple supply voltage levels and demand-specific power up sequences.

Compensate voltage drops

Using remote sensing

Improve voltage regulation and measurement accuracy with remote sensing. Regulate output voltage directly at the DUT input terminals instead of the power supply. The sense function compensates for voltage drops in supply leads, especially in applications with high current levels. R&S®NGC100 power supplies provide sense connections for each output.

Using remote sensing to compensate for load lead voltage drops
Open Lightbox

Using remote sensing to compensate for load lead voltage drops

Start instrument functions

With an external trigger

An external trigger signal (TTL) to the voltage interface on the back panel of the instrument can start an arbitrary function, activate and deactivate output delays or activate data logging.
 

Direct control of output voltage

With the analog control interface

Directly and quickly control output voltage. External analog voltage from 0 V to 10 V or current from 4 mA to 20 mA can control any or all outputs with input scaling of 0 to 100%. Galvanic isolation between the control voltage and the outputs simplifies connections while maintaining user safety even in floating circuit applications.

Available models

Available models
Modèles
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Commençant à

R&S®NGC101

Numéro de commande 3657.2288.02

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Commençant à
Prix sur demande

R&S®NGC101-G

Numéro de commande 3657.2288.03

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Commençant à
Prix sur demande

R&S®NGC102

Numéro de commande 3657.2359.02

Number of output channels
2
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
5 A
Commençant à
Prix sur demande

R&S®NGC103

Numéro de commande 3657.2413.02

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 A
Output current per channel
3 A
Commençant à
Prix sur demande

R&S®NGC103-G

Numéro de commande 3657.2413.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
3 A
Commençant à
Prix sur demande
Specifications
Electrical specifications
Number of output channels 1 / 2 / 3
Total output power max. 100 W
Maximum output power per channel 100 W/50 W/33 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 10 A/5 A/3 A
Voltage ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1 mV (RMS)
R&S®NGC102/103: < 450 µV (RMS)
Current ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1.5 mA (RMS) (meas.)
R&S®NGC102/103: < 1 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 1 ms (meas.)
Programming resolution voltage 1 mV
Programming resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
≥ 1 A: 1 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
 ≥ 1 A: 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 2 mV
Readback accuracy current ±(% of output + offset) typ. < 0.05 % + 4 mA (R&S®NGC101: typ. < 0.15 % + 10 mA)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode -
Output sequencing
External trigger
Arbitrary function ● (EasyArb)
Analog/modulation interface
Data logging
Display and interfaces
Display 3.5" QVGA
Rear panel connections Connector block with 4 lines per channel
Remote control interfaces: standard USB, LAN; R&S®NGC100-G models with IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 222 mm × 97 mm × 291 mm
Weight 2.6 kg
Rack installation R&S®HZC95 option

Available options

Rack adapter
Produit
Désignation
R&S®HZC95

Numéro de commande 5800.2054.02

Désignation

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.