86 Results
Power of ten (10-bit ADC, 10 Msample memory and 10.1" touchscreen) combined with smart operating concepts make the R&S®RTB2000 oscilloscope the perfect tool for troubleshooting embedded designs, for university laboratories as well as for production and service departments.
R&S®RTB2000 Oscilloscope - Specifications Brochures and Data Sheets Specifications
RTB2000: Status of the Trigger RTB, Trigger, Status How can I query the status of the trigger with remote commands? RTB2000: Status of the Trigger RTB, Trigger, Status How can I query the status of the trigger with remote commands?
R&S®RTB2000 Oscilloscopes Power of 10 - Fact Sheet Brochures and Data Sheets
R&S®RTB2000 versus Tektronix TBS2000 - Fact Sheet Brochures and Data Sheets
R&S®RTB2000 versus Teledyne LeCroy WaveAce 2000 - Comparison Sheet Brochures and Data Sheets
R&S®RTB2000 versus Tektronix 2 Series MSO - Comparison Sheet Brochures and Data Sheets
R&S®RTB2000 versus Keysight InfiniiVision 2000 X-Series - Comparison Sheet Brochures and Data Sheets
R&S®RTB2000 versus Rigol MSO / DS2000A - Comparison Sheet Brochures and Data Sheets
R&S®RTB2000 versus Tektronix DPO / MSO2000B - Comparison Sheet Brochures and Data Sheets
The R&S®RTB2000 digital oscilloscope lets you share your scope’s display with any computer/projector via LAN or Internet. The oscilloscope comes with an RJ-45 Ethernet jack and a built-in web server (as standard). The screen is displayed via a direct connection to a PC, via LAN or over the Internet.
Get in touch with the power of ten. Discover the R&S®RTB2000 oscilloscopes (70 MHz to 300 MHz) - Poster Brochures and Data Sheets Poster
Power electronics T&M solutions | Контрольно-измерительное оборудование для силовой электроники | Component testing, product design, production and compliance testing | Испытания компонентов, проектирование устройств, производственные и аттестационные испытания - Flyer Brochures and Data Sheets Flyer
Power electronics T&M solutions | Solutions de T&M pour l'électronique de puissance | Component testing, product design, production and compliance testing | Test de composants, conception de produits, test en production et de conformité - Flyer Brochures and Data Sheets Flyer
Fino al 49 % di sconto sulle configurazioni più comuni degli strumenti di misura Rohde & Schwarz
最も一般的な構成の電子計測器を最大49 % OFFでご提供
Économisez jusqu'à 49 % sur les configurations d'instruments T&M les plus populaires
Ahorre hasta un 49 % en las configuraciones más populares de instrumentos de T&M
Sparen Sie bis zu 49 % bei den beliebtesten Messgeräte-Konfigurationen
Save up to 49 % on the most popular T&M instrument configurations
Save up to 49 % on the most popular T&M instrument configurations
Save up to 49 % on the most popular T&M instrument configurations
Save up to 49 % on the most popular T&M instrument configurations
Save up to 49 % on the most popular T&M instrument configurations
This document provides the technical specifications of the R&S®RT-Zxx high voltage and current probes
Power electronics T&M solutions | 功率电子测试与测量解决方案 | Component testing, product design, production and compliance testing | 器件测试、产品设计、生产和一致性测试 - Flyer Brochures and Data Sheets Flyer
Power electronics T&M solutions | パワーエレクトロニクス 電子計測ソリューション | Component testing, product design, production and compliance testing | コンポーネントテスト、製品設計、製造、コンプライアンステスト - Flyer Brochures and Data Sheets Flyer
Power electronics T&M solutions | Soluciones de test y medida para electrónica de potencia | Component testing, product design, production and compliance testing | Medidas de componentes, diseño de productos, pruebas de producción y ensayos de conformidad - Flyer Brochures and Data Sheets Flyer
Instrumentos de teste R&S®ESSENTIALS para sua bancada
Power electronics T&M solutions | Component testing, product design, production and compliance testing - Flyer Brochures and Data Sheets Flyer
Osciloscopios R&S®RTC1000 y R&S®RTB2000 para las necesidades del ámbito educativo
Precision made easy | Économisez 50 % sur le pack d'applications R&S®RTB-PK1 et profitez d'une multitude d'applications. | Sales - Flyer Brochures and Data Sheets Flyer
Oscilloscope innovation. Measurement confidence. | Инновационные осциллографы. Достоверные результаты измерений. - Flyer Brochures and Data Sheets Flyer
R&S®RTC1000 and R&S®RTB2000 oscilloscopes for educational needs
Precision made easy | Risparmia il 50 % sul pacchetto di applicazioni R&S®RTB-PK1 e ottieni tanti vantaggi con una gamma completa di applicazioni. | Sales - Flyer Brochures and Data Sheets Flyer
For R&S®RTB2000, R&S®RTM3000 and R&S®RTA4000 oscilloscopes
Test and measurement specialist Rohde & Schwarz has decades of experience in producing innovative, class-leading test and measurement solutions that guarantee high quality, compatibility and precision. With its solid technological background, Rohde & Schwarz is proud to support universities and carry the legacy of cooperation forward.
Осциллографы R&S®RTC1000 и R&S®RTB2000 для образовательных нужд
R&S®RTC1000 and R&S®RTB2000 oscilloscopes for educational needs
Von der Pole-Position zur Präzision: Das R&S®RTB2004 Oszilloskop und das Miniatur Wunderland Formel-1-Projekt
From pole position to high precision: the R&S®RTB2004 oscilloscope and the Miniatur Wunderland Formula 1 project
Oscilloscope innovation. Measurement confidence. - Poster Brochures and Data Sheets Poster
Oscilloscope innovation. Measurement confidence. - Flyer Brochures and Data Sheets Flyer
R&S®RTC1000 und R&S®RTB2000 Oszilloskope für den Bildungsbereich
Oscilloscope innovation. Measurement confidence. | オシロスコープの革新、測定の核心に迫る。 - Flyer Brochures and Data Sheets Flyer
Precision made easy | 高精度を 容易に実現 | Sales - Flyer Brochures and Data Sheets Flyer
Standard probes for R&S®RTC1000, R&S®RTB2000, R&S®RTM3000, R&S®MXO 4, R&S®RTE, R&S®RTO, R&S®RTP, R&S®RTH oscilloscopes
This guide covers the most important aspects of selecting an oscilloscope and provides you with the knowledge to make the best choice for your needs.
Precision made easy | Save 50 % on the R&S®RTB-PK1 application bundle and benefit from a wide range of applications. | Sales - Flyer Brochures and Data Sheets Flyer
Precision made easy | Precisión al alcance de la mano. | Ahorre un 50 % en el paquete R&S®RTB-PK1 y disfrute de una gama completa de aplicaciones. | Sales - Flyer Brochures and Data Sheets Flyer
This document provides: - A description of how oscilloscope acquisition memory is defined - Insight into the relationship between memory and other oscilloscope parameters - Examples where deep memory provides value
Osciloscopios R&S®RTC1000 y R&S®RTB2000 para las necesidades educativas
R&S®RTC1000和R&S®RTB2000示波器满足教育需求
Precision made easy | Sparen Sie 50 % beim R&S®RTB-PK1 Applikationspaket und profitieren Sie von vielfältigen Applikationen. | Sales - Flyer Brochures and Data Sheets Flyer
R&S®RTC1000 et R&S®RTB2000 : des oscilloscopes dédiés à l'enseignement
R&S®RTC1000 and R&S®RTB2000 oscilloscopes for educational needs
Oscilloscope innovation. Measurement confidence. - Flyer Brochures and Data Sheets Flyer
本指南将介绍以下内容:- 示波器采集存储的定义 - 存储和其他示波器参数的关系 - 深存储的作用示例
Programming examples for oscilloscopes Programming examples, oscilloscopes, RTH, RTC, RTC1000, RTB, RTB2000, RTM, RTM3000, RTA, RTA4000, RTE, RTE1000, RTO, RTO1000, RTO2000, RTO6, RTP Programming examples for oscilloscopes. Programming examples for oscilloscopes Programming examples, oscilloscopes, RTH, RTC, RTC1000, RTB, RTB2000, RTM, RTM3000, RTA, RTA4000, RTE, RTE1000, RTO, RTO1000, RTO2000, RTO6
Bode plot measurement - when is it finished Bode plot measurement, RTB, RTM, RTA How can I find out that the measurement has been finished? Bode plot measurement - when is it finished Bode plot measurement, RTB, RTM, RTA How can I find out that the measurement has been finished?
Measurement of the voltage of a waveform at a certain time Measurement of voltage, waveform at certain time, captured waveform, SCPI commands I would like to measure the voltage at a certain time of a captured waveform. Do I need to use the cursor function? May I ask for the SCPI commands? Measurement of the voltage of a waveform at a certain time Measurement of voltage, waveform at certain time, captured
Output frequency of the Arbitrary Generator is wrong? RTB, RTM, RTA, output frequency, arbitrary generator When I set the frequency of the arbitrary generator to 10 KHz, the frequency of the output signal is 120 KHz. What is wrong here? Output frequency of the Arbitrary Generator is wrong? RTB, RTM, RTA, output frequency, arbitrary generator When I set the frequency of the arbitrary generator to 10
RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA,
Leackage breaker trips when probe is connected to main line RTC, RTB, RTM, RTA, RTE, RTO, Leakage breaker We want to measure the voltage of the main line with our oscilloscope. Leackage breaker trips when probe is connected to main line RTC, RTB, RTM, RTA, RTE, RTO, Leakage breaker We want to measure the voltage of the main line with our oscilloscope.
No synchronisation in Auto Trigger Mode RTC, RTB, RTM, RTA, HMO, Trigger No synchronisation in Auto Trigger Mode No synchronisation in Auto Trigger Mode RTC, RTB, RTM, RTA, HMO, Trigger No synchronisation in Auto Trigger Mode
RTB/RTM/RTA – how do I get the full resolution with CHANx:DATA? CHANx:DATA, waveform, full resolution, RTB, RTM, RTA When I query the waveform with "CHANx:DATA?" the resolution is just that what is displayed on the screen. But I have manually changed the record length to achieve a high resolution. How do I get the data of the waveform with full resolution? RTB/RTM/RTA – how do I get the full resolution
Query of waveform data when using the history and segmented memory function RTB, RTM, RTA, History and Segmented Memory How can I query the waveform data of the serveral segments? Query of waveform data when using the history and segmented memory function RTB, RTM, RTA, History and Segmented Memory How can I query the waveform data of the serveral segments?
Calibration certificate? Calibration certificate; ZNL; ZNLE; FTP1000; RTH1000; RTB2000; ZPH; FPH; FPC1000; RTM3000 Calibration certificate? Calibration certificate; ZNL; ZNLE; FTP1000; RTH1000; RTB2000; ZPH; FPH; FPC1000; RTM3000
Why does the X/Y Mode need a Trigger? RTA, RTB, RTM, X/X Mode At old scopes there was no trigger necessary to run the X/Y mode. Why does the mode not work if no valid trigger condition is detected? Why does the X/Y Mode need a Trigger? RTA, RTB, RTM, X/X Mode At old scopes there was no trigger necessary to run the X/Y mode. Why does the mode not work if no valid trigger condition is detected?
LabView Driver rsrtx - Range of Configure Trigger Channel Level RTB2000, RTM3000, RTA4000, Configure Trigger Level, FAQ, LabView Driver LabView Driver rsrtx - Range of Configure Trigger Channel Level LabView Driver rsrtx - Range of Configure Trigger Channel Level RTB2000, RTM3000, RTA4000, Configure Trigger Level, FAQ, LabView Driver LabView Driver rsrtx - Range of Configure Trigger Channel Level
RTB/RTM/RTA - reduce Stop Frequency at FFT RTB/RTM/RTA - reduce Stop Frequency at FFT RTB/RTM/RTA - reduce Stop Frequency at FFT RTB/RTM/RTA - reduce Stop Frequency at FFT RTB/RTM/RTA - reduce Stop Frequency at FFT RTB/RTM/RTA - reduce Stop Frequency at FFT
Saving a screenshot to an USB stick with remote commands Oscilloscope, HMO, RTC, RTB, RTM, RTA, HMO, RTC1000, RTB2000, RTM3000, RTA4000 Saving a screenshot to an USB stick with remote commands Saving a screenshot to an USB stick with remote commands Oscilloscope, HMO, RTC, RTB, RTM, RTA, HMO, RTC1000, RTB2000, RTM3000, RTA4000 Saving a screenshot to an USB stick with remote commands
RTB / RTM / RTA - changing the timebase with active FFT RTB, RTM, RTA, FFT With active FFT it seems that the timebase setting can not be changed. Is there a way to do that? RTB / RTM / RTA - changing the timebase with active FFT RTB, RTM, RTA, FFT With active FFT it seems that the timebase setting can not be changed. Is there a way to do that?
Waveform export to csv files shows wrong values in Excel RTO, RTE, RTP, RTM, RTB, RTC, RTA I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values? Waveform export to csv files shows wrong values in Excel RTO, RTE, RTP, RTM, RTB, RTC, RTA I have exported the waveform into a csv file. When I open the file in Excel, the
RTB/RTM/RTA/RTH - Remote Display function with Instrument View Software RTB/RTM/RTA/RTH, Remote Display function with Instrument View Software I want to use the "Remote Display" function of the Instrument View software. Instead of the screen I just see a "white" area. My PC is connected via USB. How can I use it? RTB/RTM/RTA/RTH - Remote Display function with Instrument View Software RTB/RTM/RTA/RTH
RTB/RTM/RTA Screenshots on the internal memory RTB, RTM, RTA, Screenshot I have saved some important screenshots in /INT/SCREEN path. Now I want to save/copy these data on a USB key or my PC. RTB/RTM/RTA Screenshots on the internal memory RTB, RTM, RTA, Screenshot I have saved some important screenshots in /INT/SCREEN path. Now I want to save/copy these data on a USB key or my PC.
RTB/RTM/RTA – Measurement result implausible after channel switching RTB, RTM, RTA, measurement result I do RMS measurement on a signal after switching the channels. Even with *OPC? or *WAI the result is implausible: 9.91e+37 . How can I get a correct result? RTB/RTM/RTA – Measurement result implausible after channel switching RTB, RTM, RTA, measurement result I do RMS measurement on a signal after
RTB, RTM, RTA: Acquire Mode "High Resolution" looses details? FAQ, RTB, RTM, RTA, Acquire Mode, High Resolution, details RTB, RTM, RTA: Acquire Mode "High Resolution" looses details? RTB, RTM, RTA: Acquire Mode "High Resolution" looses details? FAQ, RTB, RTM, RTA, Acquire Mode, High Resolution, details RTB, RTM, RTA: Acquire Mode "High Resolution" looses details?
Delta Time Accuracy Calculation for my Oscilloscope FAQ, Oscilloscopes, RTM, RTA, RTB, Delta Time Accuracy Calculation for my Oscilloscope Delta Time Accuracy Calculation for my Oscilloscope FAQ, Oscilloscopes, RTM, RTA, RTB, Delta Time Accuracy Calculation for my Oscilloscope
RTB / RTM / RTA Rackmount kit RTB, RTM, RTA, Rackmount kit ZZA-RTB2K I want to install the RTB / RTM / RTA into a rack and I use the rackmount kit "ZZA-RTB2K". Is the ground of the oscilloscope then connected to the frame of the rack? RTB / RTM / RTA Rackmount kit RTB, RTM, RTA, Rackmount kit ZZA-RTB2K I want to install the RTB / RTM / RTA into a rack and I use the rackmount kit "ZZA-RTB2K". Is the
Oscilloscope shows overlayed waveforms FAQ, RTB, RTM, RT, Waveform display, Oscilloscope, overlayed waveform I use the oscilloscope in RUN continious mode. When I press "STOP" more than one acquisitions are shown. The waveforms are overlayed. Is there a way to prevent this? Oscilloscope shows overlayed waveforms FAQ, RTB, RTM, RT, Waveform display, Oscilloscope, overlayed waveform I use the oscilloscope
Store results on a local PC from a RTB connected via LAN RTB, LAN, store result, TCP/IP address How to store results on a local PC from a RTB connected via LAN. Store results on a local PC from a RTB connected via LAN RTB, LAN, store result, TCP/IP address How to store results on a local PC from a RTB connected via LAN.
Can RT-ZD02 / ZD08 Probes be used at RTC/RTB/RTH? RT-ZD02, RT-ZD08, RTC, RTB, RTH Is is possible to use the differential probes RT-ZD02 or RT-ZD08 on oscilloscopes with high impedance? The impedance of the RT-ZD02/ZD08 is 50 Ohms. Can RT-ZD02 / ZD08 Probes be used at RTC/RTB/RTH? RT-ZD02, RT-ZD08, RTC, RTB, RTH Is is possible to use the differential probes RT-ZD02 or RT-ZD08 on oscilloscopes with high