R&S®RTM3000 oscilloscope

R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope, front view
Open Lightbox
R&S®RTM3000 oscilloscope, side view
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
The oscilloscope R&S®RTM3000
Open Lightbox
R&S®RTM3000 oscilloscope R&S®RTM3000 oscilloscope, front view R&S®RTM3000 oscilloscope, side view R&S®RTM3000 oscilloscope R&S®RTM3000 oscilloscope The oscilloscope R&S®RTM3000

Key facts

  • Bandwidth: 100 MHz to 1GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 80 Msample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

Starting at 3 190 EUR

  • R&S oscilloscopes | 3 years warranty extension

See more of your signal with the power of 10

Designed as daily problem-solving tool, the R&S®RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for all Rohde & Schwarz probes.

I    Four times more vertical resolution than standard 8-bit ADCs
I    Maintains fast sampling rates at all times
I    10.1" touchscreen with gesture support

Feature and Benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

RTM3000 oscilloscope
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures a vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

40 Msample standard and 80 Msample interleaved

The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.

RTM3000 oscilloscope
Open Lightbox

40 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 80 Msample standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 400 Msample with history function

The R&S®RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size the 400 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis.

RTM3000 oscilloscope
Open Lightbox

400 Msample segmented memory

Capture the longest time periods with class-leading 400 Msample memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTM-B1 option turns every R&S®RTM3000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and timecorrelated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

RTM3000 oscilloscope
Open Lightbox

4-bit DAC signal change

The R&S®RTM3000 captures and analyzes analog and digital signals synchronously and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTM-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

RTM3000 oscilloscope
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

RTM3000 oscilloscope
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTM3000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTM3000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

RTM3000 oscilloscope
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTM3000. This pulse output can be used to trigger actions in the measurement setup.

RTM3000 oscilloscope
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest signal details of a high dynamic signal matter for power measurements. Verification of RDS(on) of a MOSFET is one example. The high ADC resolution of the R&S®RTM3000 oscilloscopes increases the vertical resolution up to 10 bit. Previously unseen signal details become visible and measurable. In the example of RDS(on), it makes it possible to measure the slope of the drain-to-source-voltage while the switch is closed.

RTM3000 oscilloscope
Open Lightbox

Power analysis

Analyze the input, output and transfer function of switched-mode power supplies

Available models

  • Product Name

    R&S®RTM3002

    Order number 1335.8794.02

    Bandwidth
    100 MHz
    Channels
    2
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3004

    Order number 1335.8794.04

    Bandwidth
    100 MHz
    Channels
    4
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3002 + RTM-B222

    Order number 1335.8794P22

    Bandwidth
    200 MHz
    Channels
    2
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3004 + RTM-B242

    Order number 1335.8794P24

    Bandwidth
    200 MHz
    Channels
    4
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3002 + RTM-B223

    Order number 1335.8794P32

    Bandwidth
    350 MHz
    Channels
    2
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3004 + RTM-B243

    Order number 1335.8794P34

    Bandwidth
    350 MHz
    Channels
    4
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3002 + RTM-B225

    Order number 1335.8794P52

    Bandwidth
    500 MHz
    Channels
    2
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3004 + RTM-B245

    Order number 1335.8794P54

    Bandwidth
    500 MHz
    Channels
    4
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3002 + RTM-B2210

    Order number 1335.8794P62

    Bandwidth
    1 GHz
    Channels
    2
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
  • Product Name

    R&S®RTM3004 + RTM-B2410

    Order number 1335.8794P64

    Bandwidth
    1 GHz
    Channels
    4
    Sample Rate
    5 Gsample/s
    Max. Memory Depth
    80 Msample
    Optional MSO
    16 digital channels
    Starting at
Specifications
Vertical system
Number of channels R&S®RTM3002; R&S®RTM3004 2; 4
Bandwidth (–3 dB) at 50 Ω R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise time (calculated) R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance   50 MΩ ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivity max. bandwidth in all ranges  
  at 1 MΩ 500 μV/div to 10 V/div
  at 50 MΩ 500 μV/div to 1 V/div
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment
  input sensitivity > 5 mV/div ±1.5 % of full scale
  input sensitivity > 5 mV/div ±2 % of full scale
ADC resolution   10-bit, up to 16-bit with high resolution decimation
Acquisition system
Maximum realtime sampling rate   2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory standard; 40 Msample (80 Msample interleaved)
  with R&S®RTM-K15 option 400 Msample segmented memory
Horizontal system
Timebase range   selectable between 0.5 ns/div and 500 s/div
Trigger system
Trigger types standard edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout
  option I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,ARINC 429, MIL-STD-1553
MSO option
Digital channels   16 (2 logic probe)
Sampling rate   1.25 Gsample/s
Acquisition memory standard; 40 Msample (80 Msample interleaved)
  with R&S®RTM-K15 option 400 Msample segmented memory
Waveform generator option
Resolution, sample rate   14-bit, 250 Msample/s
Amplitude high Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high Z; 50 Ω ±5 V; ±2.5 V
Signal forms frequency ranges sine 0.1 Hz to 25 MHz
  pulse/rectangle 0.1 Hz to 10 MHz
  ramp/triangle 0.1 Hz to 1 MHz
  noise max. 25 MHz
Arbitrary sampling rate; memory depth max. 10 Msample/s; 32k points
General data
Screen   10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces   USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Audible noise maximum sound pressure level at a distance of 1.0 m 28.3 dB(A)
Dimensions W × H × D 390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight   3.3 kg (7.27 lb)

Available options

General
Product Description
RTM-B1 Mixed signal option, 400 MHz

R&S®RTM-B1

Order number 1335.8988.02

Description

Mixed signal option, 400 MHz

Turns the R&S®RTM3000 oscilloscope into fast, precise and easy-to-use mixed signal oscilloscopes (MSO)

Waveform generator

R&S®RTM-B6

Order number 1335.8994.02

Description

Arbitrary waveform generator

Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTM3000 oscilloscope.

Bandwidth upgrade
Product Description
Bandwidth upgrade

R&S®RTM-B222

Order number 1335.9003.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 200 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B223

Order number 1335.9010.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B225

Order number 1335.9026.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B2210

Order number 1335.9032.02

Description

Bandwidth upgrade of the R&S®RTM3002 to 1GHz bandwidth

Bandwidth upgrade

R&S®RTM-B242

Order number 1335.9049.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 200 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B243

Order number 1335.9055.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 350 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B245

Order number 1335.9061.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 500 MHz bandwidth

Bandwidth upgrade

R&S®RTM-B2410

Order number 1335.9078.02

Description

Bandwidth upgrade of the R&S®RTM3004 to 1 GHz bandwidth

Serial triggering and decoding
Product Description
I²C/SPI serial triggering and decoding

R&S®RTM-K1

Order number 1335.8807.02

Description

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

serial triggering and decoding

R&S®RTM-K2

Order number 1335.8813.02

Description

UART/RS-232/RS-422/RS-485 serial triggering and decoding

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

serial triggering and decoding

R&S®RTM-K3

Order number 1335.8820.02

Description

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

serial triggering and decoding

R&S®RTM-K5

Order number 1335.8842.02

Description

I²S/LJ/RJ/TDM triggering and decoding

Triggering and decoding of I²S buses

serial triggering and decoding

R&S®RTM-K6

Order number 1335.8859.02

Description

MIL-1553 serial triggering and decoding

Triggering and decoding of MIL-STD-1553 buses

serial triggering and decoding

R&S®RTM-K7

Order number 1335.8865.02

Description

ARINC 429 serial triggering and decoding

Triggering and decoding of ARINC 429 buses

General analysis
Product Description
History and segmented memory

R&S®RTM-K15

Order number 1335.8907.02

Description

History and segmented memory

History and 400 Msample segmented memory.

Spectrum analysis and spectrogram

R&S®RTM-K18*

Order number 1335.8913.02

Description

Spectrum analysis and spectrogram

The spectrum analysis option enhances the powerful FFT capability of R&S®RTM3000 oscilloscopes with spectrogram display.
* NOT distributed in North America

Power analysis

R&S®RTM-K31

Order number 1335.8920.02

Description

Power analysis

When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).

General accessories
Product Description
Front Cover

R&S®RTB-Z1

Order number 1333.1728.02

Description

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

Soft Bag

R&S®RTB-Z3

Order number 1333.1734.02

Description

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

RT-ZA19 Accessory case

R&S®RT-ZA19

Order number 1335.7875.02

Description

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

ZZA-RTB2K

R&S®ZZA-RTB2K

Order number 1333.1711.02

Description

19" rackmount adapter for R&S®RTB2000 with 5HU

RT-Z2T Probe Adapter

R&S®RT-Z2T

Order number 1338.0007.02

Description

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

Passive probes
Product Description
Passive-Probes_RT-ZP05

R&S®RT-ZP05S

Order number 1333.2401.02

Description

Passive probes, 500 MHz, 10:1

 RTM-ZP10 Passive probe

R&S®RTM-ZP10

Order number 1409.7550.00

Description

Passive probe, 500 MHz, 10:1

RT-ZP1x Passive probe

R&S®RT-ZP1X

Order number 1333.1370.02

Description

Passive probe, 38 MHz, 1:1

Active single-ended probes
Product Description
Active single-ended probe, 1 GHz, BNC interface

R&S®RT-ZS10L

Order number 1333.0815.02

Description

Active single-ended probe, 1 GHz, BNC interface

RT-ZS10E Active single-ended probe

R&S®RT-ZS10E

Order number 1418.7007.02

Description

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

RT-ZS10 Active single-ended probe

R&S®RT-ZS10

Order number 1410.4080.02

Description

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

RT-ZS20 Active single-ended probe

R&S®RT-ZS20

Order number 1410.3502.02

Description

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Product Description
RT-ZD10 Active differential probe

R&S®RT-ZD10

Order number 1410.4715.02

Description

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

RTZD10_front.jpg

R&S®RT-ZD20

Order number 1410.4409.02

Description

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Product Description
RT-ZPR20 Power rail probes

R&S®RT-ZPR20

Order number 1800.5006.02

Description

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Product Description
RT-ZH03 - 250 MHz Passive high voltage probe

R&S®RT-ZH03

Order number 1333.0873.02

Description

250 MHz passive high voltage probe

RT-ZH10 High voltage probe

R&S®RT-ZH10

Order number 1409.7720.02

Description

400 MHz passive high voltage probe

RTZH10_front.jpg

R&S®RT-ZH11

Order number 1409.7737.02

Description

400 MHz passive high voltage probe

25 MHz High voltage differential probe

R&S®RT-ZD002

Order number 1337.9700.02

Description

25 MHz high voltage differential probe

25 MHz High voltage differential probe

R&S®RT-ZD003

Order number 1337.9800.02

Description

25 MHz high voltage differential probe

RT-ZD01 High voltage probe

R&S®RT-ZD01

Order number 1422.0703.02

Description

100 MHz high voltage differential probe

RT-ZD02 Active differential probe, 200 MHz, BNC interface

R&S®RT-ZD02

Order number 1333.0821.02

Description

Active differential probe, 200 MHz, BNC interface

RTZD08 Active differential probe, 800 GHz, BNC interface

R&S®RT-ZD08

Order number 1333.0838.02

Description

Active differential probe, 800 GHz, BNC interface

RT-ZHD07 High voltage probe

R&S®RT-ZHD07

Order number 1800.2307.02

Description

200 MHz high voltage differential probe

RT-ZHD15 High voltage probe

R&S®RT-ZHD15

Order number 1800.2107.02

Description

100 MHz high voltage differential probe

RT-ZHD16 200 MHz High voltage differential probe

R&S®RT-ZHD16

Order number 1800.2207.02

Description

200 MHz high voltage differential probe

RT-ZHD60 High voltage probe

R&S®RT-ZHD60

Order number 1800.2007.02

Description

100 MHz high voltage differential probe

Current probes
Product Description
RT-ZC02 AC/DC 20 KHZ Current probe

R&S®RT-ZC02

Order number 1333.0850.02

Description

AC/DC 20 kHz current probe

RT-ZC03 100 KHZ Current probe

R&S®RT-ZC03

Order number 1333.0844.02

Description

100 kHz current probe

RT-ZC05B 2 MHz Current probe

R&S®RT-ZC05B

Order number 1409.8204.02

Description

2 MHz current probe

RT-ZC10 10 MHz Current probe

R&S®RT-ZC10

Order number 1409.7750K02

Description

10 MHz current probe

RT-ZC10B 10 MHz Current probe

R&S®RT-ZC10B

Order number 1409.8210.02

Description

10 MHz current probe

RT-ZC15B 50 MHz Current probe

R&S®RT-ZC15B

Order number 1409.8227.02

Description

50 MHz current probe

RT-ZC20 20 MHz Current probe

R&S®RT-ZC20

Order number 1409.7766K02

Description

100 MHz current probe

RT-ZC20B 100 MHz Current probe

R&S®RT-ZC20B

Order number 1409.8233.02

Description

100 MHz current probe

RT-ZC30 120 MHz Current probe

R&S®RT-ZC30

Order number 1409.7772K02

Description

120 MHz current probe

EMC near-field probes
Product Description
HZ15_front.jpg

R&S®HZ-15

Order number 1147.2736.02

Description

E and H near-field probe set

Logic probes
Product Description
RT-ZL04 400 MHz logic probe

R&S®RT-ZL04

Order number 1333.0721.02

Description

400 MHz logic probe

Probe accessories
Product Description
RT-ZA13 Power supply for probes

R&S®RT-ZA13

Order number 1409.7789.02

Description

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

RT-ZA15 External Attenuator

R&S®RT-ZA15

Order number 1410.4744.02

Description

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes

Application bundles
Product Description
Application bundle

R&S®RTM-PK1

Order number 1335.8942.02

Description

Application bundle (R&S®RTM-K1, -K2, -K3, K5, K6, K7, -K15, K18, K31 and B6)

Application bundle contains triggering and Decoding I²C/SPI (R&S®RTM-K1), UART/RS-232 (R&S®RTM-K2), CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC 429 (R&S®RTM-K7), history and segmented memory (R&S®RTM-K15), ARB generator (R&S®RTM-B6)

Application packages
Product Description
Application package

R&S®RTM3K-LSSB

Order number 1335.9149P02

Description

Low-speed serial bus package (R&S®RTM3004, -K1, -K2, -K15, -B1)

Low-speed serial bus package, contains base unit of R&S®RTM3004, trigger and decoding I2C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2), History and Segmented Memory (R&S®RTM-K15) and Mixed Signal Option (R&S®RTM-B1)

Application package

R&S®RTM3K-HVP2

Order number 1335.9132P02

Description

High voltage power package (R&S®RTM3002, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3002 and high voltage differential probe R&S®RT-ZHD60

Application package

R&S®RTM3K-HVP4

Order number 1335.9132P04

Description

High voltage power package (R&S®RTM3004, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3004 and high voltage differential probe R&S®RT-ZHD60

Application package

R&S®RTM3K-PS

Order number 1335.9126P02

Description

Power supply package (R&S®RTM3004, -K31, R&S®RT-ZHD07, R&S®RT-ZC15B)

Power supply package, contains base unit of R&S®RTM3004, Power Analysis Option (R&S®RTM-K31), high voltage differential probe R&S®RT-ZHD07, and current probe R&S®RT-ZC15B

R&S®RTM3000 - Media center

Rohde & Schwarz Oscilloscope/spectrum analyzer bundles

Buy a new R&S®RTM3000 oscilloscope from January 16, 2018 to June 30, 2018 and get a new 3 GHz R&S®FPC1000 spectrum analyzer.

Solution for

  • Analog/digital design and test

    Check out Rohde & Schwarz solutions for signal and power integrity, measurement of small signals and EMI debugging.

    More information

  • Power Electronics

    Let our test und measurement solutions assist you to create low power consuming and reliable product

    More information

Oscilloscope portfolio

  • Oscilloscopes

    Oscilloscopes that fit your requirements and your budget, from top value to top performance.

    More information

  • Oscilloscope software

    Select from a wide range of protocol triggering and decode apps, compliance testing apps, and analysis software.

    More information

  • Oscilloscope probes

    Customize your oscilloscope with the right probes and accessories for your application.

    More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

I want to receive information from Rohde & Schwarz via

What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Thank you.

Your Rohde & Schwarz-Team

Leider ist bei der Übermittlung der Daten ein Fehler aufgetreten. Bitte versuchen Sie es zu einem späteren Zeitpunkt erneut.

Ihr Rohde & Schwarz-Team

General and legal information

No product purchase to end customers.