R&S®RTE1000 Oscilloscope, Front viewR&S®RTE1000 Oscilloscope, Front viewR&S®RTE1000 Oscilloscope, Side viewR&S®RTE1000 Oscilloscope, Hero viewR&S®RTE1000 Oscilloscope, Application ImageThe R&S®RTE: Simply more scope

Key facts

  • Bandwidth: 200 MHz to 2 GHz
  • Sample rate: 5 Gsample/s
  • Max. memory depth: 200 Msample
  • Vertical resolution: up to 16-bit
  • MSO: 16 digital channels, optional, retrofittable

Starting at 6 420 EUR

  • Promo oscilloscopes
  • 10 years oscilloscopes
  • 3-year warranty extension
  • Multi-domain icon

Truly uncompromized in performance

R&S®RTE1000 oscilloscopes offer a fully integrated multi-domain test solution with time, frequency, protocol and logic analysis functions. From embedded design development to power electronics analysis to general debugging, the R&S®RTE1000 handles everyday T&M challenges quickly, accurately and easily.

  • Up to 16-bit vertical resolution
  • 200 Msample deep memory to analyze long sequences
  • Quickly find signal faults with 1 million waveforms/s
  • Touch-optimized operation

Features & benefits

More confidence in measurement results

  • Precise measurements due to very low inherent noise
  • Single-core A/D converter and up to 16-bit vertical resolution
  • Full measurement bandwidth, even at 500 μV/div
  • High time resolution combined with deep memory
  • Find rare signal faults quickly thanks to one million waveforms/s
  • Accurate triggering with a digital trigger system
 

See signal details with up to 16-bit vertical resolution in HD mode.
Open Lightbox

See signal details with up to 16-bit vertical resolution in HD mode.

More functions and faster results

  • Automatic measurements: 77 functions
  • QuickMeas: key measurement results at the push of a button
  • History function: look back in time
  • Mask test: settings in only seconds
  • FFT function: the easy way to analyze the signal spectrum
  • Search and navigation: focus on details

In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.
Open Lightbox

In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.

More fun to use

  • 10.4" high-resolution touchscreen
  • Fully customizable display
  • Fast access to important tools
  • Signal details at your fingertip
  • Documentation at the push of a button

You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.
Open Lightbox

You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.

Engineered for multi-domain challenges

  • Logic analysis: fast and precise testing of embedded designs
  • Serial protocols: easy triggering and decoding
  • Power analysis
  • Spectrum analysis
  • EMI debugging: testing during development
  • Integrated arbitrary waveform generator

The mixed signal option turns the R&S®RTE1000  oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.
Open Lightbox

The mixed signal option turns the R&S®RTE1000 oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.

Available models

Available models
Models
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Starting at

R&S®RTE1022

Order number 1326.2000.22

Bandwidth
200 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
6 420 EUR

R&S®RTE1024

Order number 1326.2000.24

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
7 610 EUR

R&S®RTE1032

Order number 1326.2000.32

Bandwidth
350 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
10 500 EUR

R&S®RTE1034

Order number 1326.2000.34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
13 500 EUR

R&S®RTE1052

Order number 1326.2000.52

Bandwidth
500 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
13 600 EUR

R&S®RTE1054

Order number 1326.2000.54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
17 400 EUR

R&S®RTE1102

Order number 1326.2000.62

Bandwidth
1 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
17 600 EUR

R&S®RTE1104

Order number 1326.2000.64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
21 800 EUR

R&S®RTE1152

Order number 1326.2000.72

Bandwidth
1.5 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
20 200 EUR

R&S®RTE1154

Order number 1326.2000.74

Bandwidth
1.5 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
25 000 EUR

R&S®RTE1202

Order number 1326.2000.82

Bandwidth
2 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
20 500 EUR

R&S®RTE1204

Order number 1326.2000.84

Bandwidth
2 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
27 000 EUR
Specifications
Vertical system
Analog channelsR&S®RTE1022/R&S®RTE1032/ R&S®RTE1052/R&S®RTE1102/ R&S®RTE1152/R&S®RTE12022
Analog channelsR&S®RTE1024/R&S®RTE1034/ R&S®RTE1054/R&S®RTE1104/ R&S®RTE1154/R&S®RTE12044
Digital channels (opt.)16
Bandwidth (-3 dB)R&S®RTE1022/R&S®RTE1024
R&S®RTE1032/R&S®RTE1034
R&S®RTE1052/R&S®RTE1054
R&S®RTE1102/R&S®RTE1104
R&S®RTE1152/R&S®RTE1154
R&S®RTE1202/R&S®RTE1204
≥ 200 MHz
≥ 350 MHz
≥ 500 MHz
≥ 1 GHz
≥ 1.5 GHz
≥ 2 GHz
Rise timeR&S®RTE1022/R&S®RTE1024
R&S®RTE1032/R&S®RTE1034
R&S®RTE1052/R&S®RTE1054
R&S®RTE1102/R&S®RTE1104
R&S®RTE1152/R&S®RTE1154
R&S®RTE1202/R&S®RTE1204
< 1.75 ns
< 1 ns
< 700 ps
< 350 ps
< 233 ps
< 175 ps
Input impedance50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF  ± 1 pF (meas.)
Input sensitivitymax. bandwidth in all ranges50 Ω: 500 μV/div to 1 V/div
1 MΩ: 500 μV/div to 10 V/div
ADC resolution8 bit
System ENOB7 bit
Acquisition system
Realtime sampling ratemax. 5 Gsample/s on each channel
Acquisition memorystandard configuration,
per channel/1 channel active
R&S®RTE1000 2-channel model: 10/20 Msample
R&S®RTE1000 4-channel model: 10/40 Msample
max. upgrade (R&S®RTE-B102 option),
per channel/1 channel active
R&S®RTE1000 2-channel model: 50/100 Msample
R&S®RTE1000 4-channel model: 50/200 Msample
Max. acquisition rate> 1 000 000 waveforms/s
Decimation modesany combination of decimation mode and waveform arithmeticssample, peak detect, high resolution,
root mean square
Waveform arithmeticsoff, envelope, average
Horizontal system
Timebase range50 ps/div to 5000 s/div
Accuracy (after delivery/calibration)±2 ppm
Channel deskew±100 ns
Trigger system
Standard Trigger typesedge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video
Optional Trigger typesserial bus trigger
Trigger sensitivitydefinition of trigger hysteresiscan be set automatically or manually from 0 div to 5 div
Analysis and measurement functions
Automatic measurements 77 measurement functions
Cursor measurements2 cursor sets, each consisting of two horizontal and two vertical cursors
Waveform mathematics4 math waveforms;
mathematics, logical operations, comparison, FIR filter, FFT
Mask testing
Mask definitionadvanced (user-configurable, hardware based)
Logic analyzer (MSO) functionality
Digital input channels16
MSO Memory depth100 Mpts per channel
MSO Bandwidth400 MHz
MSO Sampling rate5 Gsample/s per channel
MSO Input impedance100 k || 4 pF
Parallel busesup to 4
General data
DimensionsW x H x D427 mm × 249 mm × 204 mm
(16.81 in × 9.8 in × 8.03 in)
Weightwithout options, nominal8,6 kg (18.96 lb)
Display10.4" LC TFT color touchscreen,
1024 × 728 pixel (XGA)
Interfaces1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output
Operating systemWindows

Available options

General
Product
Description

Order number 1326.3570.02

Description

Mixed Signal Option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample per channel

Adds 16 digital channels to R&S®RTE1000 oscilloscopes.

Order number 1333.0750.02

Description

Digital Extension Port for R&S®RTE

Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTE-B1

Order number 1326.3012.02

Description

Arbitrary waveform generator

Add 2-channel 500 Msample/s waveform generator and 8-channel pattern generator

R&S®RTE-B10

Order number 1317.4978.02

Description

GPIB Interface

R&S®RTE-B18

Order number 1317.7002.02

Description

Replacement SSD, incl. firmware

SSD comes pre-installed with operating system and scope application

Memory upgrade
Product
Description
R&S®RTE-B101

Order number 1326.1155.02

Description

Memory upgrade to 20 Msample

Memory upgrade to 20 Msample per channel (standard for R&S®RTE with SN ≥ 300000)

R&S®RTE-B102

Order number 1326.1161.02

Description

Memory upgrade to 50 Msample

Memory upgrade to 50 Msample per channel (standard for R&S®RTE with SN ≥ 300000)

Bandwidth upgrade
Product
Description
R&S®RTE-B200

Order number 1326.1384.02

Description

Bandwidth upgrade of the R&S®RTE1022/4 to 350 MHz bandwidth, incl. calibration

R&S®RTE-B201

Order number 1326.1390.02

Description

Bandwidth upgrade of the R&S®RTE1022/4 to 500 MHz bandwidth, incl. calibration

R&S®RTE-B202

Order number 1326.1403.02

Description

Bandwidth upgrade of the R&S®RTE1022/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B203

Order number 1326.1410.02

Description

Bandwidth upgrade of the R&S®RTE1022/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B204

Order number 1326.1426.02

Description

Bandwidth upgrade of the R&S®RTE1022/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B205

Order number 1326.1432.02

Description

Bandwidth upgrade of the R&S®RTE1032/4 to 500 MHz bandwidth, incl. calibration

R&S®RTE-B206

Order number 1326.1449.02

Description

Bandwidth upgrade of the R&S®RTE1032/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B207

Order number 1326.1455.02

Description

Bandwidth upgrade of the R&S®RTE1032/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B208

Order number 1326.1461.02

Description

Bandwidth upgrade of the R&S®RTE1032/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B209

Order number 1326.1478.02

Description

Bandwidth upgrade of the R&S®RTE1052/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B210

Order number 1326.1484.02

Description

Bandwidth upgrade of the R&S®RTE1052/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B211

Order number 1326.1490.02

Description

Bandwidth upgrade of the R&S®RTE1052/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B212

Order number 1326.1503.02

Description

Bandwidth upgrade of the R&S®RTE1102/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B213

Order number 1326.1510.02

Description

Bandwidth upgrade of the R&S®RTE1102/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B214

Order number 1326.1526.02

Description

Bandwidth upgrade of the R&S®RTE1152/4 to 2 GHz bandwidth, incl. calibration

Serial triggering and decoding
Product
Description

Order number 1326.1178.02

Description

I²C/SPI triggering and decoding

Order number 1326.1184.02

Description

UART/RS-232 triggering and decoding

Order number 1326.1190.02

Description

CAN/LIN triggering and decoding

Order number 1326.1203.02

Description

FlexRay™ triggering and decoding

Order number 1326.1210.02

Description

I²S/LJ/RJ/TDM triggering and decoding

Order number 1326.1226.02

Description

MIL-1553 triggering and decoding

Order number 1326.1232.02

Description

ARINC 429 triggering and decoding

Order number 1326.1332.02

Description

Ethernet serial decoding

Order number 1326.1249.02

Description

CAN-FD triggering and decoding

Order number 1326.1603.02

Description

SENT triggering and decoding

Order number 1801.2852.02

Description

Bus analysis

Order number 1326.1326.02

Description

MANCHESTER/NRZ triggering and decoding

Order number 1326.1255.02

Description

MDIO triggering and decoding

Order number 1333.0615.02

Description

100BASE-T1 triggering and decoding

Order number 1326.1610.02

Description

USB 1.0/1.1/2.0/HSIC triggering and decoding

Order number 1326.3158.02

Description

USB-PD triggering and decoding

Order number 1326.2845.02

Description

SpaceWire triggering and decoding

Order number 1326.3193.02

Description

CXPI triggering and decoding

General analysis
Product
Description

Order number 1326.1261.02

Description

High definition mode

Order number 1326.3006.02

Description

Spectrum analysis

Order number 1326.1278.02

Description

Power analysis

Windows upgrade
Product
Description
R&S®RTE-U2

Order number 1802.9296.02

Description

Upgrade to Windows 10 (includes new PC and Windows 10 license)

R&S®RTE-U2A

Order number 1802.9338.02

Description

Upgrade to Windows 10 (includes new PC, new SSD and Windows 10 license)

Accessories
Product
Description
R&S®RTO-Z1

Order number 1333.0096.02

Description

Front Cover

Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope

R&S®RTO-Z3

Order number 1304.9118.02

Description

Soft Case

Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories

R&S®RTO-Z4

Order number 1317.7025.02

Description

Transit case

Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport

Order number 1317.7031.02

Description

Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes

R&S®ZZA-RTO

Order number 1304.8286.00

Description

19" Rackmount Adapter

For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 19" rack with 6U heigth

R&S®RT-Z2T

Order number 1338.0007.02

Description

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

Passive probes
Product
Description

Order number 1409.7550.00

Description

Passive probe, 500 MHz, 10:1

Active single-ended probes
Product
Description

Order number 1418.7007.02

Description

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4080.02

Description

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Order number 1410.3502.02

Description

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Order number 1410.4309.02

Description

Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Product
Description

Order number 1410.4715.02

Description

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4609.02

Description

Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface

Order number 1410.4409.02

Description

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Modular probe system
Product
Description

Order number 1800.4700.02

Description

Modular probe amplifier module, 1.5 GHz

Order number 1419.3005.02

Description

Modular probe amplifier module, 3 GHz

R&S®RT-ZMA10

Order number 1419.4301.02

Description

Solder-in probe tip cable for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA10-6

Order number 1801.4349.02

Description

Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system

>16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA11

Order number 1419.4318.02

Description

Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA12

Order number 1419.4324.02

Description

Square-pin probe tip module for R&S®RT-ZM modular probe system

> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA15

Order number 1419.4224.02

Description

Quick connect probe tip module for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA30

Order number 1419.4353.02

Description

Browser module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, DM

R&S®RT-ZMA40

Order number 1419.4201.02

Description

SMA module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA50

Order number 1419.4218.02

Description

Temperature kit for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

Power rail probes
Product
Description

Order number 1800.5006.02

Description

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

Multi-channel power probes
Product
Description

Order number 1326.0259.02

Description

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs

Order number 1326.0259.04

Description

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs

High voltage probes
Product
Description

Order number 1333.0873.02

Description

250 MHz passive high voltage probe

Order number 1409.7720.02

Description

400 MHz passive high voltage probe

Order number 1409.7737.02

Description

400 MHz passive high voltage probe

Order number 1333.0821.02

Description

Active differential probe, 200 MHz, BNC interface

Order number 1333.0838.02

Description

Active differential probe, 800 GHz, BNC interface

Order number 1800.2107.02

Description

100 MHz High voltage differential probe

Order number 1800.2207.02

Description

200 MHz High voltage differential probe

Order number 1800.2007.02

Description

100 MHz High voltage differential probe

Current probes
Product
Description

Order number 1333.0850.02

Description

AC/DC 20 kHz current probe

Order number 1333.0844.02

Description

100 kHz current probe

Order number 1409.8204.02

Description

2 MHZ current probe

Order number 1409.7750K02

Description

10 MHZ current probe

Order number 1409.8210.02

Description

10 MHZ Current probe

Order number 1409.8227.02

Description

50 MHZ Current probe

Order number 1409.7766K02

Description

100 MHZ current probe

Order number 1409.8233.02

Description

100 MHZ current probe

Order number 1409.7772K02

Description

120 MHz current probe

Order number 1801.4932.02

Description

120 MHz current probe

R&S®EMC near field probes
Product
Description

Order number 1147.2736.02

Description

E and H near-field probe set

Application bundles
Product
Description
R&S®RTE-TDBNDL

Order number 1326.4190.02

Description

Trigger and decode bundle option

Decode more than 28 serial protocols with the R&S®RTE trigger and decode software bundle. T&D bundle includes I2C/SPI, UART/RS232, CAN/LIN, FlexRay, I2S, MIL, ARINC, Ethernet, CAN-FD, SENT, Custom, MDIO, USB2.0, USB-PD, SpaceWire, CXPI

RTE1000 - Media center

Power Integrity - capture 1

The quality of the power supply is a key factor in the functionality and performance of sensitive electronic circuits.

19-May-2018

R&S®Multi-domain debugging of embedded IoT devices

This video demonstrates the multi-domain test capabilities of Rohde & Schwarz oscilloscopes.

09-Mar-2018

Power Integrity - capture 2

5 tips on how to make more precise measurements

07-Mar-2018

R&S®RTE - Tutorial: Zoom

Basic introduction to the operation of the zoom functionality.

15-Feb-2018

R&S®RTE - Tutorial: Toolbar

Basic introduction to the operation of the toolbar functionality.

15-Feb-2018

R&S®RTE - Tutorial: Smart Grid

Basic introduction to the operation of the smart grid functionality.

15-Feb-2018

R&S®RTE - Tutorial: Mask Test

Basic introduction to the operation of the mask test functionality.

15-Feb-2018

R&S®RTE - Tutorial: Histogram

Basic introduction to the operation of the histogram functionality.

15-Feb-2018

RTE Application videos - Media center

UART/RS232/RS485 Triggering on Break condition

Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.

13-Feb-2020

In depth analysis of your RS232 interface

In depth analysis of RS232 interfaces frame by frame using the R&S®RTO decode table and zoom window.

13-Feb-2020

Debug RS232, RS485 or UART interfaces

Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.

13-Feb-2020

I²C Debugging with hardware trigger of RTO

How to identify and trace down errors in I²C interfaces using the Hardware Trigger together with History Mode.

13-Feb-2020

Possibilities provided by the I²C decode protocol

Dive into your protocol to check for any problems with your I²C interface.

13-Feb-2020

The right set up to Decode I²C with an oscilloscope

Discover how to easily decode I²C with the right setup, as shown on an R&S®RTO.

13-Feb-2020

Power Integrity - capture 1

The quality of the power supply is a key factor in the functionality and performance of sensitive electronic circuits.

19-May-2018

R&S®Multi-domain debugging of embedded IoT devices

This video demonstrates the multi-domain test capabilities of Rohde & Schwarz oscilloscopes.

09-Mar-2018

Also interesting for you

10 years Rohde & Schwarz oscilloscopes

10 years of Rohde & Schwarz oscilloscope innovation

More information

Oscilloscopes promotion

Oscilloscopes promotion

Choose the right R&S promotion for your individual needs and save your budget

More information

Rohde & Schwarz webinars

Oscilloscope webinar center for digital design and power electronics applications

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.