Power integrity measurements with R&S®RTM3000 and R&S®RTA4000 oscilloscopes

Make more accurate power rail measurements.

Measurement of a 1.5 V power rail using an R&S®RT-ZP10 10:1, 500 MHz passive probe (50 mV (Vpp), noise masks signal details).
Measurement of a 1.5 V power rail using an R&S®RT-ZP10 10:1, 500 MHz passive probe (50 mV (Vpp), noise masks signal details).
Open Lightbox
Measurement of a 1.5 V power rail using an R&S®RT-ZP1x 1:1 passive, 38 MHz probe (31.8 mV (Vpp)). Bandwidth limiting eliminates the ability to see higher frequency transients.
Measurement of a 1.5 V power rail using an R&S®RT-ZP1x 1:1 passive, 38 MHz probe (31.8 mV (Vpp)). Bandwidth limiting eliminates the ability to see higher frequency transients.
Open Lightbox

Your task

Measuring noise and ripple on power rails with small voltages and increasingly tighter tolerances is a challenge for oscilloscopes. Using a standard 500 MHz passive probe with a 10:1 attenuation results in additional measurement noise, causing overstated peak-to-peak voltage measurements and masking signal details as shown below.

Passive probes with 1:1 attenuation have less noise, but are bandwidth limited to around 35 MHz. They miss higher frequency content that may be riding on the power rail and may understate peak-to-peak-voltages.

Measurement of a 1.5 V power rail using an R&S®RT-ZPR20 1:1 active power rail probe (–38.3 mV (Vpp)). The captured waveform includes higher frequency transients riding on the rail.
Measurement of a 1.5 V power rail using an R&S®RT-ZPR20 1:1 active power rail probe (–38.3 mV (Vpp)). The captured waveform includes higher frequency transients riding on the rail.
Open Lightbox

Rohde & Schwarz solution

Combining a low-noise oscilloscope with a power rail probe, developed uniquely for measuring power rails, provides a measurement system that delivers measurements that are more accurate. The R&S®RT-ZPR20 active probe with a 1:1 attenuation ratio has very little noise and enough bandwidth to not attenuate critical signal content.

When combined with an R&S®RTA4000 or R&S®RTM3000 oscilloscope, the R&S®RT-ZPR20 power rail probe provides the following benefits:

  • The probe’s 1:1 attenuation provides minimal noise for a system noise of less than 500 μV (at 1 GHz bandwidth and 10 mV/div)
  • With ±60 V of built-in offset, users can center and zoom in a wide variety of DC rail voltage standards without worrying about how much built-in offset the scope has. The offset eliminates the need to use AC coupling or DC blocking capacitors, which impede the ability to see true DC values and drift
  • High-frequency transients and coupled signals are isolated. The probe’s rated bandwidth is 2 GHz. When used with an R&S®RTA4000 or R&S®RTM3000, overall bandwidth is set by the oscilloscope bandwidth
  • 50 kΩ DC input impedance minimizes loading, so DC values remain accurate
  • An integrated 16-bit R&S®ProbeMeter provides a simultaneous five-digit readout of each power rail’s DC value
R&S®RT-ZPR20 power rail probe
R&S®RT-ZPR20 power rail probe