Key Facts
- Bandwidth: 100 MHz to 1GHz
- Sample rate: up to 5 Gsample/s
- Memory depth: up to 80 Msample
- ADC resolution: 10-bit
- Display: 10.1’’ capacitive touchscreen
Commençant à 4 110 EUR
Key Facts
Commençant à 4 110 EUR
Designed as daily problem-solving tool, the R&S®RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for all Rohde & Schwarz probes.
Quick Links
See small signal details in the presence of large signals
The R&S®RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.
40 Msample standard and 80 Msample interleaved
The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.
Segmented memory: 400 Msample with history function
The R&S®RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size the 400 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis.
16 additional digital channels
The R&S®RTM-B1 option turns every R&S®RTM3000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and timecorrelated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.
Generate analog and digital stimuli
The R&S®RTM-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.
Measure and display electrical potential
The R&S®RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.
Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTM3000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTM3000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.
Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTM3000. This pulse output can be used to trigger actions in the measurement setup.
See power signal details with up to 10-bit resolution
Even the smallest signal details of a high dynamic signal matter for power measurements. Verification of RDS(on) of a MOSFET is one example. The high ADC resolution of the R&S®RTM3000 oscilloscopes increases the vertical resolution up to 10 bit. Previously unseen signal details become visible and measurable. In the example of RDS(on), it makes it possible to measure the slope of the drain-to-source-voltage while the switch is closed.
Numéro de commande 1335.8794.02
Numéro de commande 1335.8794.04
Numéro de commande 1335.8794P22
Numéro de commande 1335.8794P24
Numéro de commande 1335.8794P32
Numéro de commande 1335.8794P34
Numéro de commande 1335.8794P52
Numéro de commande 1335.8794P54
Numéro de commande 1335.8794P62
Numéro de commande 1335.8794P64
Vertical system | ||
Analog channels | R&S®RTM3002; R&S®RTM3004 | 2; 4 |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz |
Rise time | R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps |
Input impedance | 50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.) | |
Input sensitivity | max. bandwidth in all ranges | at 1 MΩ: 500 μV/div to 10 V/div at 50 Ω: 500 μV/div to 1 V/div |
ADC resolution | 10 bit, up to 16 bit with high resolution decimation | |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment | input sensitivity > 5 mV/div: ±1.5 % of full scale input sensitivity > 5 mV/div: ±2 % of full scale |
Acquisition system | ||
Realtime sampling rate | 2.5 Gsample/s; 5 Gsample/s, interleaved | |
Acquisition memory | standard: 40 Msample (80 Msample interleaved) with R&S®RTM-K15 option: 400 Msample segmented memory |
|
Max. acquisition rate | 64 000 waveforms/s (2 000 000 in fast segmented memory mode) |
|
Horizontal system | ||
Timebase range | selectable between 0.5 ns/div and 500 s/div | |
Accuracy (after delivery/calibration) | ±2.5 ppm | |
Channel-to-channel skew | < 200 ps (meas.) | |
Channel deskew | ±500 ns | |
Trigger system | ||
Standard Trigger types | edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout | |
Optional Trigger types | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,ARINC 429, MIL-STD-1553 | |
Trigger sensitivity | with DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.) | |
Analysis and measurement functions | ||
Automatic measurements | 32 | |
Cursor measurements | 4 | |
Waveform mathematics | 5 equations math on math (addition, substraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) | |
Mask testing | ||
Mask definition | elementary (tolerance mask around the signal) | |
History and segmented memory | ||
Number of segments | up to 34 952 | |
Protocol trigger and decode | ||
Supported protocols | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429 | |
Waveform generator | ||
Resolution | 14-bit | |
Sample rate | 250 Msample/s | |
Amplitude | high Z; 50 Ω | 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp) |
DC offset | high Z; 50 Ω | ±5 V; ±2.5 V |
Arbitrary | sampling rate; memory depth | max. 10 Msample/s; 32k points |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO Memory depth | two logic probes: 40 Msample for every channel one logic probe: 80 Msample for every channel |
|
MSO Bandwidth | 400 MHz (meas.) | |
MSO sampling rate | 2.5 Gsample/s | |
MSO input impedance | 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips | |
Parallel buses | up to 4 | |
General data | ||
Dimensions | W × H × D | 390 mm × 220 mm × 152 mm (15.4 in × 8.66 in × 5.98 in) |
Weight | 3.3 kg (7.27 lb) | |
Display | 10.1" WXGA TFT color display (1280 × 800 pixel) | |
Interfaces | USB host with MTP, USB device, LAN, powerful web server for remote display and operation | |
Operating system | Embedded |
Numéro de commande 1335.8988.02
Mixed signal option, 400 MHz
The RTM-B1 MSO option is a powerful tool for debugging digital designs with a sampling rate of up to 5 GSa/s and a memory depth of up to 20 Msa.
Numéro de commande 1335.8994.02
Arbitrary waveform generator
Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTM3000 oscilloscope.
Numéro de commande 1335.9003.02
Bandwidth upgrade of the R&S®RTM3002 to 200 MHz bandwidth
Numéro de commande 1335.9010.02
Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth
Numéro de commande 1335.9026.02
Bandwidth upgrade of the R&S®RTM3002 to 500 MHz bandwidth
Numéro de commande 1335.9032.02
Bandwidth upgrade of the R&S®RTM3002 to 1GHz bandwidth
Numéro de commande 1335.9049.02
Bandwidth upgrade of the R&S®RTM3004 to 200 MHz bandwidth
Numéro de commande 1335.9055.02
Bandwidth upgrade of the R&S®RTM3004 to 350 MHz bandwidth
Numéro de commande 1335.9061.02
Bandwidth upgrade of the R&S®RTM3004 to 500 MHz bandwidth
Numéro de commande 1335.9078.02
Bandwidth upgrade of the R&S®RTM3004 to 1 GHz bandwidth
Numéro de commande 1335.8807.02
I²C/SPI serial triggering and decoding
Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses
Numéro de commande 1335.8813.02
UART/RS-232/RS-422/RS-485 serial triggering and decoding
Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses
Numéro de commande 1335.8820.02
CAN/LIN serial triggering and decoding
Triggering and decoding of CAN and LIN interfaces
Numéro de commande 1335.8842.02
I²S/LJ/RJ/TDM triggering and decoding
Triggering and decoding of I²S buses
Numéro de commande 1335.8859.02
MIL-1553 serial triggering and decoding
Triggering and decoding of MIL-STD-1553 buses
Numéro de commande 1335.8865.02
ARINC 429 serial triggering and decoding
Triggering and decoding of ARINC 429 buses
Numéro de commande 1335.8907.02
History and segmented memory
History and 400 Msample segmented memory.
Numéro de commande 1335.8920.02
Power analysis
When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).
Numéro de commande 1335.9178.02
Frequency Response Analysis (Bode plot)
The R&S®RTM-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.
Numéro de commande 1335.9184.02
Spectrum analysis and spectrogram
The spectrum analysis option enhances the powerful FFT capability of R&S®RTM3000 oscilloscopes with spectrogram display
Numéro de commande 1333.1728.02
Front cover
Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000
Numéro de commande 1335.9290.02
Transit case with wheels for R&S®RTB
Numéro de commande 1333.1734.02
Soft bag
Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories
Numéro de commande 1335.7875.02
Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes
Numéro de commande 1333.1711.02
19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU
Numéro de commande 1338.0007.02
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Numéro de commande 1333.2401.02
Passive probe, 500 MHz, 10:1
Numéro de commande 1409.7550.00
Passive probe, 500 MHz, 10:1
Numéro de commande 1333.1370.02
Passive probe, 38 MHz, 1:1
Numéro de commande 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Numéro de commande 1333.0873.02
250 MHz passive high voltage probe
Numéro de commande 1409.7720.02
400 MHz passive high voltage probe
Numéro de commande 1409.7737.02
400 MHz passive high voltage probe
Numéro de commande 1800.2307.02
200 MHz High voltage differential probe
Numéro de commande 1800.2107.02
100 MHz High voltage differential probe
Numéro de commande 1800.2207.02
200 MHz High voltage differential probe
Numéro de commande 1800.2007.02
100 MHz High voltage differential probe
Numéro de commande 1333.0850.02
AC/DC 20 kHz current probe
Numéro de commande 1333.0844.02
100 kHz current probe
Numéro de commande 1409.8204.02
2 MHZ current probe
Numéro de commande 1409.7750K02
10 MHZ current probe
Numéro de commande 1409.8210.02
10 MHZ Current probe
Numéro de commande 1409.7766K02
100 MHZ current probe
Numéro de commande 1409.8233.02
100 MHZ current probe
Numéro de commande 1801.4932.02
120 MHz current probe
Numéro de commande 1409.7772K02
120 MHz current probe
Numéro de commande 1147.2736.02
E and H near-field probe set
Numéro de commande 1333.0721.02
400 MHz logic probe
Numéro de commande 1409.7789.02
Power supply for probes
Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A
Numéro de commande 1410.4744.02
External attenuator
10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.
Numéro de commande 1335.8942.02
Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), spectrum analysis and spectrogram (R&S®RTM-K37), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models
Numéro de commande 1335.9190.02
Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), spectrum analysis and spectrogram (R&S®RTM-K37), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models * ONLY distributed in North America
Numéro de commande 1335.9149P02
Low-speed serial bus package (R&S®RTM3004, -K1, -K2, -K15, -B1)
Low-speed serial bus package, contains base unit of R&S®RTM3004, trigger and decoding I2C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2), History and Segmented Memory (R&S®RTM-K15) and Mixed Signal Option (R&S®RTM-B1)
Numéro de commande 1335.9132P04
High voltage power package (R&S®RTM3004, R&S®RT-ZHD60)
High voltage power package, contains base unit of R&S®RTM3004 and high voltage differential probe R&S®RT-ZHD60
Numéro de commande 1335.9132P02
High voltage power package (R&S®RTM3002, R&S®RT-ZHD60)
High voltage power package, contains base unit of R&S®RTM3002 and high voltage differential probe R&S®RT-ZHD60
Numéro de commande 1335.9126P02
Power supply package (R&S®RTM3004, -K31, R&S®RT-ZHD07, R&S®RT-ZC15B)
Power supply package, contains base unit of R&S®RTM3004, Power Analysis Option (R&S®RTM-K31), high voltage differential probe R&S®RT-ZHD07, and current probe R&S®RT-ZC15B
Produits associés
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz
1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").
2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.
3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.
4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.
5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :
Prix : 1x oscilloscope numérique R&S®RTB2000
6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.
7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.
8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.
9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.
10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.
11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.
12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.
13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.