R&S®ESPI Test Receiver

The reference instrument for the EMI precompliance class

Ce produit n'est plus fabriqué.
Plus d'informations ? Veuillez nous contacter.

Key Facts

  • Combination of precertification EMI test receiver and high-quality spectrum analyzer
  • Integrated preselection with selectable 20 dB preamplifier (R&S®ESPI-B2 option)

Brief Description

The R&S®ESPI test receivers are especially designed to meet all EMC testing demands during product development and for EMC precertification in the frequency range from 9 kHz to 3/7 GHz.

Features

  • Standard-compliant disturbance measurements for PRFs ≥ 10 Hz
  • Spectrum analysis for lab applications
  • Intuitive operation and powerful analysis functions for fast, accurate results

Specifications

Frequency range  
R&S®ESPI3 9 kHz to 3 GHz
R&S®ESPI7 9 kHz to 7 GHz

Key Facts

  • Combination of precertification EMI test receiver and high-quality spectrum analyzer
  • Integrated preselection with selectable 20 dB preamplifier (R&S®ESPI-B2 option)
  • Weighting detectors in line with the latest version of CISPR 16-1-1 incl. CISPR-Average and RMS-Average
  • Evaluation of field strength profiles at very high measurement rates (R&S®ESPI-K50 option)
  • Fast and reliable measurements using automatic and interactive test routines
  • Predefined transducer factors
  • Library of limit lines for commercial standards
  • Additional channel filters with various bandwidths between 5.6 MHz and 8 MHz matching terrestrial DVB networks like DVB-T/T2 (R&S®ESPI-K50 option)

Brief Description

The R&S®ESPI test receivers are especially designed to meet all EMC testing demands during product development and for EMC precertification in the frequency range from 9 kHz to 3/7 GHz. Equipped with the R&S®ESPI-B2 preselector/preamplifier option, all R&S®ESPI models feature an excellent dynamic range and are therefore able to perform precise interference measurements for pulse repetition frequencies ≥ 10 Hz in line with CISPR 16-1-1. With the R&S®ESPI-K50 option they can also be used for measurement of the coverage field strength of communications or broadcast networks at very high measurement rates.

Features & Benefits

  • Standard-compliant disturbance measurements for PRFs ≥ 10 Hz
    • Total measurement uncertainty 1.5 dB (≤ 3 GHz) in receiver mode
    • 1 dB compression 0 dBm nominal
    • Displayed average noise level with preamplifier typ. –155 dBm (1 Hz), f < 1 GHz
    • Eleven preselection filters up to 3 GHz (R&S®ESPI-B2 option)
    • 20 dB preamplifier (R&S®ESPI-B2 option)
    • Resolution bandwidths in line with CISPR 16-1-1
    • Detectors in line with CISPR 16-1-1: peak, quasi-peak, average, RMS, CISPR average, RMS average
  • Spectrum analysis for lab applications
    • High-quality spectrum analyzer included (R&S®FSP)
    • Extensive measurement functions and evaluation capabilities for general lab applications
  • Intuitive operation and powerful analysis functions for fast, accurate results
    • User-friendly operation as with all modern EMI test receivers from Rohde & Schwarz
    • SCAN settings in tabular format
    • Simultaneous measurement of up to three traces for parallel evaluation
    • Fast, reliable measurements using automatic and interactive test routines
    • EMI test receiver and spectrum analyzer in a single box
    • Continuous bargraph display and marker functions for precise measurements
    • Automatic disturbance voltage measurements using remote-controllable line impedance stabilization networks (LISN) from Rohde & Schwarz
    • Predefined transducer factors
    • Library of limit lines for commercial standards
    • Measurement of the coverage field strength of communications or broadcast networks at very high measurement rates (R&S®ESPI-K50 option)
    • Additional channel filters with various bandwidths between 5.6 MHz and 8 MHz matching all terrestrial DVB networks incl. DVB-T2 (R&S®ESPI-K50 option)
  • Integrates perfectly into the work environment
    • Easy expansion or upgrading by means of options
      • Scalar network analysis
      • RF level measurement
      • Modulation measurement
    • Extensive documentation and networking capabilities like a PC
    • Computer-controlled measurement of disturbances and automated EMI test routines using the R&S®ES-SCAN and R&S®EMC32 EMI measurement software
    • Always up-to-date with free firmware updates
  • Rugged and environmentally friendly, suitable even for field applications
    • Housing option for outdoor use
      • Shock-absorbing corners, carrying handle, carrying bag
    • AC-independent operation using DC power supply and battery pack (option)
    • Flash disk option for expanded environmental specifications
    • Environmentally friendly design
      • Few materials
      • Labeling for easy identification of materials
      • Recyclable housing

Specifications

Frequency range R&S®ESPI3: 9 kHz to 3 GHz
R&S®ESPI7: 9 kHz to 7 GHz
Frequency resolution 0.01 Hz
Frequency accuracy standard 1 × 10-6
with R&S®FSP-B4 (OCXO) option 1 x 10-7
External reference frequency 10 MHz
Measurement time receiver mode/scan (per frequency step) selectable from 100 µs to 100 s
analyzer mode/sweep time selectable from 2.5 ms to 16000 s,
zero span from 1 µs to 16000 s
Resolution bandwidth analyzer mode (–3 dB) 10 Hz to 3 MHz in steps of 1/3/10
receiver mode (EMI) 200 Hz, 9 kHz, 120 kHz (–6 dB),
1 MHz (impulse bandwidth)
Video bandwidth analyzer mode 1 Hz to 10 MHz in steps of 1/3/10
Preselection
(R&S®ESPI-B2 option)
can be turned off in analyzer mode 11 fixed/continuously tunable filters up to 3 GHz
Preamplifier
(R&S®ESPI-B2 option)
can be switched on/off 20 dB gain up to 3 GHz
Level
Max. RF level (CW) input attenuation ≥ 10 dB 137 dBµV (= 1 W)
Max. pulse energy input attenuation ≥ 10 dB, 10 µs 1 mWs
Max. pulse voltage input attenuation ≥ 10 dB, 10 µs 150 V
Third-order intercept (IP3) without preselection/preamplifier,
from 200 MHz to 3 GHz
from 3 GHz to 7 GHz
> 7 dBm, typ. 10 dBm
> 2 dBm, typ. 5 dBm (only at R&S®ESPI7)
with preselection/without preamplifier,
from 200 MHz to 3 GHz
> 2 dBm, typ. 5 dBm
1 dB compression f > 200 MHz, input attenuation 0 dB,
without preselection/preamplifier
0 dBm, nominal
Total measurement uncertainty 95 % confidence level
< 3 GHz
without preselection/preamplifier 0.5 dB
with preselection/preamplifier 1.5 dB
Displayed average noise level (DANL) receiver mode, nominal,
input attenuation 0 dB, termination 50 Ω
without preselection/preamplifier, 1 MHz, BW = 9 kHz < 17 dBμV
without preselection/preamplifier, 30 MHz to 1 GHz,
BW = 120 kHz
< 6 dBμV
with preselection/preamplifier, 1 MHz, BW = 9 kHz < 7 dBμV
with preselection/preamplifier, 30 MHz to 1 GHz,
BW = 120 kHz
< - 4 dBμV
Detectors receiver mode max./min. peak, quasi-peak, RMS,
average, average with meter time
constant (CISPR average), RMS
average (CISPR RMS)
Number of measurement points analyzer mode 125 to 8001 (default 501)
receiver mode max. 1 million (frequency domain)
Merci.

Votre demande a bien été envoyée !

Nous vous contacterons très bientôt.

Votre équipe de service Rohde & Schwarz

Obtenir une démonstration

Veuillez saisir votre demande.
Veuillez saisir votre prénom.
Veuillez saisir votre nom.
Veuillez saisir une adresse électronique valide.
Veuillez saisir le nom de votre entreprise.
Veuillez saisir le nom de votre ville.
Veuillez saisir votre code postal.

Veuillez saisir votre ville.
Marketing de permission

Je souhaite recevoir des informations de Rohde & Schwarz via


Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Veuillez saisir les caractères présentés sur l'image.
show captcha
La saisie est incorrecte.
Do not enter data in this field
Merci.

Votre demande a bien été envoyée !

Nous vous contacterons très bientôt.

Votre équipe de service Rohde & Schwarz

Obtenir un devis

Veuillez saisir votre demande.
Veuillez saisir votre prénom.
Veuillez saisir votre nom.
Veuillez saisir une adresse électronique valide.
Veuillez saisir le nom de votre entreprise.
Veuillez saisir le nom de votre ville.
Veuillez saisir votre code postal.
Veuillez saisir votre numéro de téléphone.

Veuillez saisir votre ville.
Marketing de permission

Je souhaite recevoir des informations de Rohde & Schwarz via


Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Veuillez saisir les caractères présentés sur l'image.
show captcha
La saisie est incorrecte.
Do not enter data in this field
Merci.

Votre demande a bien été envoyée !

Nous vous contacterons très bientôt.

Votre équipe de service Rohde & Schwarz

Demander des informations

Veuillez saisir votre demande.
Veuillez saisir votre prénom.
Veuillez saisir votre nom.
Veuillez saisir une adresse électronique valide.
Veuillez saisir le nom de votre entreprise.
Veuillez saisir le nom de votre ville.
Veuillez saisir votre code postal.

Veuillez saisir votre ville.
Marketing de permission

Je souhaite recevoir des informations de Rohde & Schwarz via


Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Veuillez saisir les caractères présentés sur l'image.
show captcha
La saisie est incorrecte.
Do not enter data in this field
International Website