R&S®NRPM OTA power measurement solution

R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®OTA power measurement solution, RF shield box
Open Lightbox
R&S®NRPM-A90 single-polarized antenna module
Open Lightbox
R&S®NRPM-A90D dual-polarized antenna module
Open Lightbox
R&S®NRPM3 3-channel sensor module
Open Lightbox
R&S®NRPM-Z3 interface module
Open Lightbox
R&S®NRPM-ZD3 filtered feedthrough module
Open Lightbox
R&S®NRPM OTA power measurement solution R&S®OTA power measurement solution, RF shield box R&S®NRPM-A90 single-polarized antenna module R&S®NRPM-A90D dual-polarized antenna module R&S®NRPM3 3-channel sensor module R&S®NRPM-Z3 interface module R&S®NRPM-ZD3 filtered feedthrough module

Key facts

  • Frequency range from 18 GHz to 90 GHz
  • Ideal for beamforming tests
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements
  • 3 years warranty extension

Designed for extremly accurate Over-the-Air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.

Features & benefits

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain and antenna pattern and from mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, the antenna pattern and the diode detector are calibrated together. Complicated system calibration by the user is not necessary.

Open Lightbox

OTA power measurement system

Low-reflection antenna module

Low radar cross section to avoid disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideally suited for use in a screened environment, due to the virtual absence of reflections.

Open Lightbox

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

R&S®NRPM OTA power measurement solution therefore uses a highly sensitive diode detector which is integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules are therefore able to measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be determined precisely.

Open Lightbox

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the receiver of the DUT, it is necessary to know exactly the power at the DUT, transmitted OTA to the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT to calibrate the transmit power of the signal generator. The calibration is done with an R&S®NRPM-A90/A90D antenna module, which is then replaced by the DUT. The receive power of the DUT is then exactly known.

Open Lightbox

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power of all antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane functions properly. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged in at least two horizontal planes.

Open Lightbox

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
  relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty (measurement distance 1m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
  relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Product Description
R&S®NRPM- A90 single polarized antenna module

R&S®NRPM-A90

Order number 1426.7760.02

Description

Single-polarized antenna module

Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power measurements.

R&S®NRPM-A90D dual-polarized antenna module

R&S®NRPM-A90D

Order number 1426.7777.02

Description

Dual-polarized antenna module

Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.

Sensor modules
Product Description
NRPM3-Three-Channel_Sensor_Module_img1.jpg

R&S®NRPM3

Order number 1425.8563.02

Description

Three-channel sensor module

Interface for shielded RF test box
Product Description
R&S NRPM-ZD3 filtered cable feedthrough

R&S®NRPM-ZD3

Order number 1425.8786.02

Description

Filtered cable feedthrough

R&S®NRPM-ZKD3 interface cable

R&S®NRPM-ZKD3

Order number 1425.8770.02

Description

Interface cable

Interface for benchtop application
Product Description
R&S®NRPM-Z3 interface module

R&S®NRPM-Z3

Order number 1426.7602.02

Description

Interface module

The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.

General accessories
Product Description
NRP-ZKU USB interface cable

R&S®NRP-ZKU

Order number 1419.0658.02

Description

USB interface cable, length: 0.75 m

NRP-ZKU USB interface cable

R&S®NRP-ZKU

Order number 1419.0658.03

Description

USB interface cable, length: 1.5 m

NRP-ZKU USB interface cable

R&S®NRP-ZKU

Order number 1419.0658.04

Description

USB interface cable, length: 3 m

NRP-ZKU USB interface cable

R&S®NRP-ZKU

Order number 1419.0658.05

Description

USB interface cable, length: 5 m

R&S®NRP-ZK6

Order number 1419.0664.02

Description

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Order number 1419.0664.03

Description

6-pole interface cable, length: 3 m

R&S®NRP-ZK6

Order number 1419.0664.04

Description

6-pole interface cable, length: 5 m

NRP-Z5_Sensor_Hub_front.jpg

R&S®NRP-Z5

Order number 1146.7740.02

Description

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

R&S®NRPM-ZKT

Order number 1425.8857.02

Description

Trigger cable

Related videos

Utilisation du R&S®NRPM

mai 18, 2020

Comprendre les mesures de puissance sans fil

mai 18, 2020

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Je souhaite recevoir des informations de Rohde & Schwarz via

Marketing de permission

Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.