Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our instruments

R&S®SMA100B RF and microwave signal generator

R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator
Open Lightbox
R&S®SMA100B RF and microwave signal generator, Front Low R&S®SMA100B RF and microwave signal generator, Front Low R&S®SMA100B RF and microwave signal generator, Back low R&S®SMA100B RF and microwave signal generator, Front Low R&S®SMA100B RF and microwave signal generator, Back low R&S®SMA100B RF and microwave signal generator, Side view

Key Facts

  • Frequency range: 8 kHz to 3, 6, 12.75, 20, 31.8, 40, 50 and 67 GHz (overrange up to 72 GHz)
  • SSB phase noise of  –132 dBc (typ.) at 10 GHz and 10 kHz offset
  • Wideband noise of –162 dBc (meas.) at 10 GHz and 30 MHz offset
  • Maximum output power exceeds 30 dBm across wide frequency ranges
  • Exceptionally low harmonics

Performance leadership without compromise

The R&S®SMA100B RF and microwave signal generator delivers uncompromising maximum performance. It provides the purest output signals while maintaining the highest output power levels with the lowest harmonics, far outpacing the competition. As the world's leading signal generator, it can handle the most demanding module and system T&M tasks in the RF semiconductor, wireless communications, aerospace and defense industries.

Caractéristiques & avantages

First-class devices thanks to first-class signals

The R&S®SMA100B delivers uncompromising maximum performance. 

  • It provides the purest output signals with the highest output power levels and the lowest harmonics.
  • Frequency range from 8 kHz up to 67 GHz (overrange 72 GHz)
  • Lowest SSB phase noise of –132 dBc (typ.) at 10 GHz and 10 kHz offset
  • Virtually no wideband noise of –162 dBc (meas.) at 10 GHz and 30 MHz offset
  • Maximum output power exceeds 30 dBm across wide frequency ranges
  • Exceptionally low harmonics
  • State-of-the-art GUI with touch display

SSB phase noise for different frequencies
Open Lightbox

SSB phase noise for different frequencies

Measured SSB phase noise performance of the R&S®SMA100B with the R&S®SMAB-B711(N) option

Very high uncompromising output power

Large dynamic range, excellent level accuracy and level repeatability 

Very high output power is often required in the microwave frequency range because the higher the frequency, the more attenuation. The R&S®SMA100B offers different output power stages to compensate for such losses. As a result, no downstream external amplifier is required. Exceptionally high output power levels (measured values)

  • Ultra high output power up to 38 dBm with the 6 GHz instrument
  • Over 30 dBm at 18 GHz and 28 dBm at 20 GHz with the 20 GHz instrument
  • Over 30 dBm between 20 GHz and 36 GHz with the 40 GHz instrument
  • Over 22 dBm between 40 GHz and 65 GHz with the 67 GHz instrument

 Maximum measured output power
Open Lightbox

Maximum measured output power

Measured maximum available output power for the 50 GHz and the 67 GHz instrument (standard, high and ultra-high output power options)

User friendly in every detail

Easy integration into test systems and innovative operating features

  • Flexible 2 HU or 3 HU housing
  • 3 HU with large 7" display and multiple front panel connectors
  • Ergonomic GUI with touch display
  • Frequently used menu items can be added to user menus for quick and easy access to any necessary settings in one place
  • The R&S®SMA100B also has a SCPI macro recorder with a code generator to automatically record manual settings and create an executable MATLAB® script

Innovative operating features
Open Lightbox

Innovative operating features

The built-in SCPI macro recorder and code generator supports fast, easy generation of SCPI program sequences

R&S®LegacyPro: refresh your technology

Trade in your legacy signal generators

R&S®LegacyPro enables the R&S®SMA100B to reliably emulate a wide range of legacy generators from vendors such as Keysight, Agilent, HP, Anritsu and Rohde & Schwarz. As a result, the R&S®SMA100B can be deployed in legacy systems without major software changes, effectively increasing uptime, lowering cost of ownership and lengthening the useful life of the test system.

R&S®LegacyPro
Open Lightbox

R&S®LegacyPro

Enjoy plug and play replacement of your legacy signal generators with R&S®LegacyPro and the R&S®SMA100B;

High-end ADC and DAC component testing

Measure the true performance of your device 

Analog input bandwidth and required clock frequency increase with each new ADC generation. The increase in the effective number of bits also results in a larger signal-to-noise ratio. This means that extremely clean, high-frequency signals exceeding the DUT performance are required to test ADCs and DACs. The outstanding R&S®SMA100B performance is perfect for optimizing DUTs and making improvements technically feasible in the first place.

The R&S®SMA100B in an ADC/DAC application
Open Lightbox

The R&S®SMA100B in an ADC/DAC application

Compact ADC test setup for clock signals up to 6 GHz using a single R&S®SMA100B with an integrated second source

 R&S®NRP power sensor connectivity

An R&S®NRP power sensor can be connected to the R&S®SMA100B;

A DUT is rarely connected directly to the generator. Cables and other components are often between the generator and the DUT. This shifts the reference plane from the generator RF output to the DUT. An R&S®NRP power sensor can be connected to the R&S®SMB100B for extremely precise calibration (tenth of a dB) on the new reference plane.

 R&S®NRP power sensor connectivity
Open Lightbox

R&S®NRP power sensor connectivity

R&S®SMA100B with connected Rohde & Schwarz power sensor

UCOR (user correction)

Compensation of an external frequency response

DUTs are often connected to the signal generator via long cables or other frequency dependent components, making it very important to compensate for frequency response. The R&S®SMA100B provides a user correction (UCOR) function for this purpose. Together with an R&S®NRP power sensor, the UCOR values are automatically determined at the push of a button. A frequency response compensated RF signal is available at the new reference plane for UCOR.

Setup and UCOR function
Open Lightbox

Setup and UCOR function

Relative output power display when using cables and other components (with their own frequency response) between the R&S®SMA100B and a DUT.

Variable reference frequency inputs/outputs

The R&S®SMA100B provides various ways to output (or input) reference signals. The 1 MHz to 100 MHz variable external reference frequency input (R&S®SMAB-K704 option) allows the R&S®SMA100B to be easily integrated into existing test environments. The received reference frequency can also be assigned to a completely different reference output.

Variable reference frequency inputs/outputs
Open Lightbox

Variable reference frequency inputs/outputs

The R&S®SMA100B rear panel reference frequency inputs and outputs

Uninterrupted level sweep with high dynamic range

When measuring gain transfer function or output saturation point in amplifiers with an integrated automatic level control (ALC), the signal generator must provide a wide uninterrupted level sweep range. The R&S®SMA100B with the R&S®SMAB-K724  option provides the following:

  • Blank-free (uninterrupted) level sweep with exceptionally high dynamic range
  • High level linearity across the entire level sweep range

Open Lightbox

Uninterrupted high dynamic range level sweep with the R&S®SMA100B;

Available options

Frequency options
Produit
Désignation
R&S®SMAB-B103

Numéro de commande 1420.8488.02

Désignation

8 kHz to 3 GHz

R&S®SMAB-B106

Numéro de commande 1420.8588.02

Désignation

8 kHz to 6 GHz

R&S®SMAB-B112

Numéro de commande 1420.8688.02

Désignation

8 kHz to 12.75 GHz

R&S®SMAB-B120

Numéro de commande 1420.8788.02

Désignation

8 kHz to 20 GHz

R&S®SMAB-B131

Numéro de commande 1420.8888.02

Désignation

8 kHz to 31.8 GHz

R&S®SMAB-B140

Numéro de commande 1420.8988.02

Désignation

8 kHz to 40 GHz

R&S®SMAB-B140N

Numéro de commande 1420.8965.02

Désignation

8 kHz to 40 GHz, limited minimum pulse width

R&S®SMAB-B150

Numéro de commande 1420.9049.02

Désignation

8 kHz to 50 GHz

R&S®SMAB-B150N

Numéro de commande 1420.9026.02

Désignation

8 kHz to 50 GHz, limited minimum pulse width

R&S®SMAB-B167

Numéro de commande 1420.9149.02

Désignation

8 kHz to 67 GHz

R&S®SMAB-B167N

Numéro de commande 1420.9126.02

Désignation

8 kHz to 67 GHz, limited minimum pulse width

R&S®SMAB-B29

Numéro de commande 1420.8088.02

Désignation

Differential clock synthesizer, 3 GHz

R&S®SMAB-K722

Numéro de commande 1420.9810.02

Désignation

Clock synthesizer frequency extension to 6 GHz

Phase noise performance options
Produit
Désignation
R&S®SMAB-B709

Numéro de commande 1420.9849.02

Désignation

Low Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140(N)/-B150(N)/-B167(N)

R&S®SMAB-B710

Numéro de commande 1420.8007.02

Désignation

Improved Close-in Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140/-B150/-B167

R&S®SMAB-B710N

Numéro de commande 1420.8107.02

Désignation

Improved Close-in Phase Noise for R&S®SMAB-B103

R&S®SMAB-B711

Numéro de commande 1420.8020.02

Désignation

Ultra Low Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140/-B150/-B167

R&S®SMAB-B711N

Numéro de commande 1420.8120.02

Désignation

Ultra Low Phase Noise for R&S®SMAB-B103

Reference oscillator options
Produit
Désignation
R&S®SMAB-B1H

Numéro de commande 1420.8188.02

Désignation

High Performance OCXO Reference Oscillator

R&S®SMAB-K703

Numéro de commande 1420.9761.02

Désignation

100 MHz, 1 GHz Reference Input and Output

R&S®SMAB-K704

Numéro de commande 1420.9778.02

Désignation

Flexible Reference Input 1 MHz to 100 MHz

Output power options
Produit
Désignation
R&S®SMAB-K31

Numéro de commande 1420.7100.02

Désignation

High output power, 3 GHz/6 GHz

R&S®SMAB-B32

Numéro de commande 1420.7200.02

Désignation

Ultra high output power, 3 GHz/6 GHz

R&S®SMAB-K33

Numéro de commande 1420.7300.02

Désignation

High output power, 12.75 GHz/20 GHz

R&S®SMAB-B34

Numéro de commande 1420.7400.02

Désignation

Ultra high output power, 12.75 GHz/20 GHz

R&S®SMAB-B35

Numéro de commande 1420.7500.02

Désignation

High output power 31.8 GHz/40 GHz

R&S®SMAB-K36

Numéro de commande 1420.9178.02

Désignation

Ultra high output power 31.8 GHz/40 GHz

R&S®SMAB-B36S

Numéro de commande 1420.9190.02

Désignation

Super ultra high output power 31.8 GHz/40 GHz

R&S®SMAB-B37

Numéro de commande 1420.7700.02

Désignation

High output power 50 GHz

R&S®SMAB-K38

Numéro de commande 1420.9255.02

Désignation

Ultra high output power 50 GHz

R&S®SMAB-B39

Numéro de commande 1420.7900.02

Désignation

High output power 67 GHz

R&S®SMAB-K40

Numéro de commande 1420.9278.02

Désignation

Ultra high output power 67 GHz

Analog modulation options
Produit
Désignation
R&S®SMAB-K22

Numéro de commande 1420.9710.02

Désignation

High Performance Pulse Modulator

R&S®SMAB-K23

Numéro de commande 1420.9726.02

Désignation

Pulse Generator

R&S®SMAB-K24

Numéro de commande 1420.9732.02

Désignation

Multifunction Generator

R&S®SMAB-K25

Numéro de commande 1420.9855.02

Désignation

VOR/ILS

R&S®SMAB-K27

Numéro de commande 1420.9749.02

Désignation

Pulse Train

R&S®SMAB-K720

Numéro de commande 1420.9790.02

Désignation

AM/FM/φM

R&S®SMAB-K721

Numéro de commande 1420.9784.02

Désignation

Scan AM

R&S®SMAB-K724

Numéro de commande 1420.9832.02

Désignation

High dynamic uninterrupted level sweep

R&S®SMAB-K725

Numéro de commande 1420.9861.02

Désignation

Chirp signal generation

R&S®SMAB-B28

Numéro de commande 1420.6579.02

Désignation

Ramp sweep

Other options
Produit
Désignation
R&S®SMAB-B80

Numéro de commande 1420.6504.02

Désignation

Rear panel connectors (3 GHz/6 GHz)

R&S®SMAB-B81

Numéro de commande 1420.6510.02

Désignation

Rear panel connectors (12.75 GHz/20 GHz/31.8 GHz/ 40 GHz)

R&S®SMAB-B82

Numéro de commande 1420.6527.02

Désignation

Rear panel connectors (50 GHz/67 GHz) PC 1.85 mm

Extras
Produit
Désignation
R&S®ZZA-KNP21

Numéro de commande 1177.8803.00

Désignation

19" Rackmount Kit

19" rack adapter for devices with 19" rack width and 2 height units

R&S®ZZA-KNP31

Numéro de commande 1177.8810.00

Désignation

19" rack adapter for 3 HU model

R&S®TS-USB1

Numéro de commande 6124.2531.00

Désignation

USB serial adapter for RS-232 remote control

R&S®SMAB-Z10

Numéro de commande 1420.6662.02

Désignation

Spare SD card

R&S®SMAB-B85

Numéro de commande 1420.6556.02

Désignation

Removable mass storage

R&S®SMAB-B86

Numéro de commande 1420.6562.02

Désignation

Remote control GPIB and USB

R&S®SMAB-K28

Numéro de commande 1420.9755.02

Désignation

Power analysis

Documentation
Produit
Désignation
R&S®DCV-2

Numéro de commande 0240.2193.18

Désignation

Documentation of Calibration Values

R&S®ACASMA100B

Numéro de commande 3598.3307.03

Désignation

R&S®DCV-2 0240.2193.18 R&S®SMA100B accredited calibration; up to 6 GHz

R&S®ACASMA100B

Numéro de commande 3598.3236.03

Désignation

R&S®SMA100B accredited calibration; 12.75 GHz to 40 GHz

R&S®ACASMA100B

Numéro de commande 3598.3207.03

Désignation

R&S®SMA100B accredited calibration; 50 GHz to 67 GHz

Base unit options
Produit
Désignation
R&S®SMAB-B92

Numéro de commande 1420.8288.04

Désignation

Platform height option: 2 HU with 5" touch display

R&S®SMAB-B93

Numéro de commande 1420.8388.04

Désignation

Platform height option: 3 HU with 7" touch display

Base unit options
Produit
Désignation
R&S®SMAB-K554

Numéro de commande 1420.9884.02

Désignation

Multiplier Control

Related videos

Simulation d'angle d'arrivée pour des récepteurs multivoies

Cette vidéo montre comment définir un scénario de recherche de direction dans le logiciel R&S®Pulse Sequencer et comment visualiser le scénario sur une configuration R&S®SMW200A à 4 voies ayant été aligné en termes d'amplitude, de temporisation et de phase.

déc. 09, 2020

R&S®SMW200A - Alignement des ports RF - Guide de démarrage rapide

Cette vidéo montre comment configurer les générateurs de signaux vectoriels R&S®SMW200A et comment utiliser l'option d'alignement des ports RF SMW-K545 avec le logiciel PC RFPAL, afin de générer plusieurs signaux alignés en amplitude, temporisation et phase à l'entrée d'un dispositif sous test multivoies.

déc. 09, 2020

R&S®SMA100B – Balayage de niveau continu à dynamique élevée

Cette vidéo présente comment profiter de la fonction de balayage de niveau continu à dynamique élevée du Rohde & Schwarz ® SMA100B pour la mesure des courbes de transfert de gain des amplificateurs.

sept. 16, 2019

R&S®SMA100B - Des signaux avec un bruit de phase plus faible

Développement de radar, test de convertisseurs de données, tests de blocage de stations de base - tous nécessitent un bruit de phase faible aux fréquences de décalage pertinentes.

sept. 16, 2019

R&S®SMA100B – Mesure de la distorsion harmonique d'amplificateurs à puissance élevée

Cette vidéo présente comment le R&S®SMA100B peut délivrer simultanément en sortie des signaux à puissance très élevée, avec des harmoniques plus faibles.

sept. 16, 2019

R&S®SMA100B - Vidéo produit

La vidéo de l'appareil illustre la performance exceptionnelle sans compromis du générateur de signaux micro-ondes et RF R&S®SMA100B.

juil. 23, 2019

Le signal qui fait la différence

Cette vidéo propose la présentation en ligne du SMA100B.

févr. 12, 2019

Génération innovante de signaux analogiques pulsés

Cette vidéo présente comment il devient simple de générer des impulsions étroites en utilisant le R&S®SMA100B.

févr. 12, 2019

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.