Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our instruments

R&S®SMB100A microwave signal generator

R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator
Open Lightbox
R&S®SMB100A microwave signal generator, Front viewR&S®SMB100A microwave signal generator, Front HighR&S®SMB100A microwave signal generator, Side viewR&S®SMB100A microwave signal generator, Back viewR&S®SMB100A microwave signal generator, Hero viewR&S®SMB100A microwave signal generator, Hero viewR&S®SMB100A microwave signal generator, Application ImageR&S®SMB100A microwave signal generator, Application Image

Key Facts

  • Frequency range: 100 kHz to 12.75, 20, 31.8 and 40 GHz
  • SSB phase noise of  –108 dBc (typ.) at 10 GHz and 20 kHz offset
  • Wideband noise of –138 dBc at 10 GHz and 30 MHz offset
  • High output power of up to +27 dBm (meas.)
  • Analog modulations with AM, FM/φM and pulse modulation supported

Versatile, compact, up to 40 GHz; 170 GHz with upconverter

The compact, versatile R&S®SMB100A microwave signal generator with a frequency range up to 40 GHz provides outstanding spectral purity and high output power. In addition, it features easy operation, comprehensive functionality and low cost of ownership. The R&S®SMB100A provides microwave characteristics that are exceptional in its class, making it an excellent general purpose instrument. Its outstanding characteristics, compact size and low weight make the instrument ideal for a wide range of applications. The R&S®SMB100A is optimally suited for use in development, production and service, or simply wherever an analog microwave signal is needed.

 

Caractéristiques & avantages

Best signal quality in the mid-range

Lowest SSB Phase noise, harmonics, nonharmonics and wideband noise

  • Very low SSB phase noise of typ. –108 dBc at 10 GHz  (20 kHz carrier offset, 1 Hz measurement bandwidth)
  • Optional internal low harmonic filters for the 20 GHz and 40 GHz model to lower the harmonics to less than –50 dBc for frequencies above 150 MHz
  • Innovative DDS-based synthesizer concept 

SSB phase noise for different frequencies
Open Lightbox

SSB phase noise for different frequencies

Measured SSB phase noise with the R&S®SMB-B1H OCXO option for the 12.75/20/31.8/40 GHz model.

High output power and wide level range 

High output power of up to +27 dBm (meas.)

The R&S®SMB100A combines excellent signal quality with a high output power of > +18 dBm as standard for the 12.75 GHz instrument. The maximum measured available output power is up to +27 dBm.
The R&S®SMB-B31 high power option for the 20 GHz model delivers a specified output power of +19 dBm while the R&S®SMB-B32 high power option for the 40 GHz model achieves +16 dBm over a wide frequency range up to 20 GHz and 40 GHz.

Maximum measured output power
Open Lightbox

Maximum measured output power

Maximum available output level versus frequency (meas.).

Ideal for production 

Easy integration into test systems and innovative operating features

  • Wear-free electronic attenuator up to 12.75 GHz ensuring long operating life
  • High level accuracy and repeatability for high production yield
  • Closed loop power control ensures highly accurate and very stable input power to the DUT irrespective of unwanted power drifts in the test setup
  • Short frequency and level settling times which can be further reduced in list mode
  • Low power consumption

Closed loop power control
Open Lightbox

Closed loop power control

Closed loop power control ensures highly accurate and stable input power to the DUT irrespective of unwanted power drifts or setup changes

Supports R&S®NRP-Zxx power sensors

The R&S®SMB100A supports a variety of R&S®NRP-Zxx USB power sensors.

The R&S®NRP-Z55 is a power sensor that provides an ideal enhancement to the frequency  and level range of the generator up to 40 GHz. Equipped with this power sensor, the R&S®SMB100A automatically performs external level correction and precisely measures power in the test setup.

R&S®NRP power sensor connectivity
Open Lightbox

R&S®NRP power sensor connectivity

R&S®SMB100A with connected Rohde & Schwarz power sensor

 

UCOR (user corretion)

Compensation for external frequency response

DUTs are often connected to the signal generator via long cables or other frequency dependent components, making it very important to compensate for frequency response. The R&S®SMB100A provides a user correction (UCOR) function for this purpose. Together with the R&S®NRP power sensor, UCOR values are automatically determined at the push of a button. The UCOR enables a frequency response compensated RF signal at the new reference plane.

Setup and UCOR function
Open Lightbox

Setup and UCOR function

Relative output power display when using cables and other components (with their own frequency responses) between the R&S®SMB100A and a DUT.

Frequency extension from 50 GHz to 170 GHz

  • R&S®SMB100A signal generator (≥ 20 GHz) plus an external R&S®SMZ frequency multiplier controlled via USB
  • An internal attenuator (mechanically or electronically controlled) can be integrated into the same housing as the frequency multiplier

R&S®SMB100A plus R&S®SMZ110
Open Lightbox

R&S®SMB100A plus R&S®SMZ110

R&S®SMB100A microwave signal generator (20 GHz or 40 GHz) and the R&S®SMZ110 frequency multiplier with built-in electronically controlled attenuator.

Closed loop power control

A directional coupler and a connected R&S®NRP-Zxx power sensor can be used to measure DUT input power. An attractive alternative to the directional coupler is the R&S®NRP-Z28 level control sensor. The measurement from the R&S®NRP-Zxx or the R&S®NRP-Z28 is fed back to the R&S®SMB100A, which immediately adjusts its output power to compensate for the discrepancy between the wanted and the measured levels.

Closed loop power control with the R&S®SMB100A
Open Lightbox

Closed loop power control with the R&S®SMB100A

Closed loop power control ensures highly accurate and stable input power to the DUT, irrespective of unwanted power drifts or changes in the setup

Available options

Frequency options
Produit
Désignation
R&S®SMB-B112

Numéro de commande 1407.2109.02

Désignation

100 kHz to 12.75 GHz, with electronic step attenuator

R&S®SMB-B112L

Numéro de commande 1407.2150.02

Désignation

100 kHz to 12.75 GHz, without step attenuator

R&S®SMB-B120

Numéro de commande 1407.2209.02

Désignation

100 kHz to 20 GHz, with mechanical step attenuator

R&S®SMB-B120L

Numéro de commande 1407.2250.02

Désignation

100 kHz to 20 GHz, without step attenuator

R&S®SMB-B131

Numéro de commande 1407.2280.02

Désignation

100 kHz to 31.8 GHz, with mechanical step attenuator

R&S®SMB-B140

Numéro de commande 1407.2309.02

Désignation

100 kHz to 40 GHz, with mechanical step attenuator

R&S®SMB-B140L

Numéro de commande 1407.2350.02

Désignation

100 kHz to 40 GHz, without step attenuator

R&S®SMB-B140N

Numéro de commande 1407.2380.02

Désignation

100 kHz to 40 GHz, with mech. step att., minimum pulse width limited

Reference oscillator options
Produit
Désignation
R&S®SMB-B1

Numéro de commande 1407.3005.02

Désignation

OCXO Reference Oscillator

R&S®SMB-B1H

Numéro de commande 1407.3070.02

Désignation

OCXO Reference Oscillator, High Performance

Analog modulation options
Produit
Désignation
R&S®SMB-K21

Numéro de commande 1407.3811.02

Désignation

Pulse Modulator

for R&S®SMB-B112/-B112L/-B120/-B120L/-B131/-B140/-B140N/-B140L

R&S®SMB-K23

Numéro de commande 1407.3786.02

Désignation

Pulse Generator

R&S®SMB-K27

Numéro de commande 1407.3828.02

Désignation

Pulse Train

Requires an R&S®SMB-K23 option, only available for instruments with serial number > 102400.

Performance enhancement options
Produit
Désignation
R&S®SMB-B31

Numéro de commande 1407.1260.02

Désignation

High power, 50 MHz to 20 GHz (for R&S®SMB-B120/-B120L)

R&S®SMB-B32

Numéro de commande 1407.1360.02

Désignation

High Power, 50 MHz to 40 GHz (only available with R&S®SMB-B131/-B140/-B140N/-B140L)

R&S®SMB-B25

Numéro de commande 1407.1660.02

Désignation

Harmonic filter, (for R&S®SMB-B120/-B120L)

R&S®SMB-B26

Numéro de commande 1407.1760.02

Désignation

Harmonic filter, (for R&S® SMB-B131/-B140/-B140L/-B140N)

Features and functions
Produit
Désignation
R&S®SMB-B30

Numéro de commande 1407.1160.02

Désignation

Reverse Power Protection (for R&S®SMB-B112, R&S®SMB-B112L)

Extras
Produit
Désignation
R&S®ZZA-S234

Numéro de commande 1109.4493.00

Désignation

19" Rack Adapter

R&S®TS-USB1

Numéro de commande 6124.2531.00

Désignation

USB serial adapter for RS-232 remote control

Documentation
Produit
Désignation
R&S®DCV-2

Numéro de commande 0240.2193.09

Désignation

Documentation of calibration values

R&S®ACASMB100A

Numéro de commande 3596.9508.03

Désignation

Accredited calibration

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.