Key Facts
- Unparalleled low phase noise and best sensitivity on the market
- 8.3 GHz internal analysis bandwidth
- 800 MHz real-time analysis bandwidth
- SCPI recorder simplifies code generation
- High dynamic range enables outstanding EVM performance
Key Facts
Experience everyday excellence with the FSW, the high-performance signal and spectrum analyzer that redefines precision. Ideal for a variety of applications – from complex communication systems to RF components – this powerful analyzer is your trusted partner for reliable measurements and unparalleled phase noise performance. Whether developing high-performance radars or characterizing wideband components, the wide internal analysis bandwidth and exceptional accuracy of the FSW set signal analysis standards. You can trust the FSW for the most demanding tasks, day after day.
Quick Links
RF performance that meets exacting demands
The FSW redefines the top-of-the-line signal and spectrum analyzers, offering superior RF phase noise, displayed average noise level, intermodulation suppression and dynamic range for ACLR and harmonic measurements.
Designed for convenience
In-depth 5G physical layer signal analysis
Fast and comprehensive radar signal analysis
In addition to wide analysis bandwidth (up to 8.3 GHz), FSW analysis functions essential for radar testing.
Image-free wideband signal analysis in the E band
The R&S®FSW85 signal and spectrum analyzer features a YIG preselector for frequencies between 8 GHz and 85 GHz, providing image-free spectrum analysis. The wide analysis bandwidth (up to 8.3 GHz) combined with the R&S®FSW-K60/-K60C transient analysis/chirp measurement option allows you to characterize up to 5 GHz wide FMCW signals such as those used in automotive radars.
High-performance measurement solutions for designing, developing and testing satellite payloads, payload subsystems and components
The FSW offers dedicated measurement applications for the most critical measurements such as group delay, linearity, gain transfer, noise power ratio (NPR), etc. It also demodulates satellite RF signals of several standards such as DVB-S2X and OneWeb. The FSW scalable, wide analysis bandwidth (up to 8.3 GHz) meets the increasing demand for wide signal bandwidths.
Don’t miss a thing with the real-time spectrum analysis option
The FSW real-time options allow users to reliably detect extremely short sporadic interference in the nanosecond range even in close proximity to powerful carriers – in a bandwidth of up to 800 MHz. Real-time spectrum analysis enables users to analyze existing frequency hopping algorithms and create alternative ones to prevent collisions between signals of different standards operating in the same frequency band.
Digital signal analysis
The R&S®FSW-K70 vector signal analysis option enables users to flexibly analyze digitally modulated single carriers down to the bit level. The clearly structured operating concept simplifies measurements despite a wide range of analysis tools.The R&S®FSW-K70M allows analysis of signals with two different modulation schemes, such as DVB-S2X signals.The R&S®FSW-K70P extension measures the raw bit error rate (BER) on PRBS data up to PRBS23.
Numéro de commande 1331.5003.08
Numéro de commande 1331.5003.13
Numéro de commande 1331.5003.26
Numéro de commande 1331.5003.43
Numéro de commande 1331.5003.50
Numéro de commande 1331.5003.67
Numéro de commande 1331.5003.85
Numéro de commande 1313.0703.02
OCXO precision frequency reference
Numéro de commande 1313.2464.02
Resolution bandwidth up to 80 MHz
for R&S®FSW43 / R&S®FSW50 / R&S®FSW67 / R&S®FSW85
Export license required.
Numéro de commande 1313.2464.26
Resolution bandwidth up to 80 MHz
for R&S®FSW8 / R&S®FSW13 / R&S®FSW26
Numéro de commande 1338.6911.02
Resolution bandwidth 40 MHz
Numéro de commande 1313.0761.02
Highpass filter for harmonic measurements
Numéro de commande 1313.0990.02
Electronic attenuator, 1 dB steps
for R&S®FSW8 / R&S®FSW13 / R&S®FSW26
Numéro de commande 1331.7693.02
Frequency extension, 90 GHz
for R&S®FSW85 only;
without preselection for f > 85 GHz
Numéro de commande 1313.0832.13
RF preamplifier, 100 kHz to 13.6 GHz
for R&S®FSW8 / R&S®FSW13
Numéro de commande 1313.0832.26
RF preamplifier, 100 kHz to 26.5 GHz
for R&S®FSW26
Numéro de commande 1313.0832.43
RF preamplifier, 100 kHz to 43.5 GHz
for R&S®FSW43 / R&S®FSW67
No export license required.
Numéro de commande 1313.0832.49
RF preamplifier, 100 kHz to 50 GHz
for R&S®FSW50
No export license required.
Numéro de commande 1313.0832.51
RF preamplifier, 100 kHz to 50 GHz
for R&S®FSW50
Export license required.
Numéro de commande 1313.0832.66
RF preamplifier, 100 kHz to 67 GHz
for R&S®FSW67
No export license required.
Numéro de commande 1313.0832.67
RF preamplifier, 100 kHz to 67 GHz
for R&S®FSW67
Export license required.
Numéro de commande 1313.0861.02
40 MHz analysis bandwidth
Numéro de commande 1313.0878.02
80 MHz analysis bandwidth
Numéro de commande 1325.4850.14
160 MHz analysis bandwidth
Numéro de commande 1325.4867.14
320 MHz analysis bandwidth
Numéro de commande 1331.7106.14
512 MHz analysis bandwidth
Numéro de commande 1331.6400.14
1200 MHz analysis bandwidth
Not available for the R&S®FSW8 and R&S®FSW13. Not in combination with R&S®FSW-B2000.
Numéro de commande 1331.6916.14
2000 MHz analysis bandwidth
Not available for the R&S®FSW8 and R&S®FSW13. Not in combination with R&S®FSW-B2000.
Numéro de commande 1338.5215.14
4400 MHz analysis bandwidth
Not available for R&S®FSW8, R&S®FSW13 and R&S®FSW26
Numéro de commande 1338.5221.14
6400 MHz analysis bandwidth
Not available for R&S®FSW8, R&S®FSW13 and R&S®FSW26
Numéro de commande 1338.5238.14
8312 MHz analysis bandwidth
Not available for R&S®FSW8, R&S®FSW13 and R&S®FSW26
Numéro de commande 1325.4750.02
2 GHz analysis bandwidth
R&S®RTO2044 / R&S®RTO1044 oscilloscope required. Not available for the R&S®FSW8 and R&S®FSW13.
Numéro de commande 1331.6997.85
5 GHz analysis bandwidth
Available for the R&S®FSW85. R&S®RTO2064 oscilloscope required. Not available in combination with R&S®FSW-B2000.
Numéro de commande 1331.6997.43
5 GHz analysis bandwidth
Available for the R&S®FSW43. R&S®RTO2064 oscilloscope required. Not available in combination with R&S®FSW-B2000.
Numéro de commande 1313.1100.28
LO/IF connections for external mixers
for R&S®FSW26 / R&S®FSW43 / R&S®FSW50 / R&S®FSW67
Numéro de commande 1313.1100.86
LO/IF connections for external mixers
for R&S®FSW85
Numéro de commande 1313.0784.02
Digital baseband interface
Numéro de commande 1331.6980.02
DIG IQ 40G streaming out interface
R&S®FSW-B512/-U512/-B1200/-U1200/-B2001/-U2001/-B800R required
Numéro de commande 1350.7008.02
DIG IQ 40G streaming out interface 1GHz
R&S®FSW-B1200/-U1200/-B2001/-U2001/-B800R required
Numéro de commande 1313.1651.13
Analog baseband inputs, 40 MHz analysis bandwidth
for R&S®FSW8 / R&S®FSW13
Numéro de commande 1313.1651.26
Analog baseband inputs, 40 MHz analysis bandwidth
for R&S®FSW26 / R&S®FSW43 / R&S®FSW50
Numéro de commande 1313.1651.67
Analog baseband inputs, 40 MHz analysis bandwidth
for R&S®FSW67
Numéro de commande 1313.1651.86
Analog baseband inputs, 40 MHz analysis bandwidth
for R&S®FSW85
Numéro de commande 1313.6547.02
80 MHz analysis bandwidth for analog baseband inputs
R&S®FSW-B71 required
Numéro de commande 1331.8302.02
Oscilloscope baseband inputs
Numéro de commande 1331.6451.02
I/Q memory extension, 6 GB
R&S®FSW-B160/‑U160/‑B320 required
Numéro de commande 1331.6751.02
I/Q memory extension, 8 GB
R&S®FSW-B1200, R&S®FSW-B2001 or R&S®FSW-B800R required
Numéro de commande 1338.5273.02
I/Q memory extension 24 Gbyte
Requires R&S®FSW-B4001, R&S®FSW-B6001 or R&S®FSW-B8001.
Numéro de commande 1313.1622.02
External generator control
Numéro de commande 1313.0790.10
Spare solid state drive (removable hard drive)
Numéro de commande 1313.1368.02
GSM/EDGE/EDGE evolution/VAMOS measurements
Numéro de commande 1313.1422.02
3GPP FDD (WCDMA) BS measurements (incl. HSDPA and HSDPA+)
Numéro de commande 1313.1439.02
3GPP FDD (WCDMA) MS measurements (incl. HSUPA and HSUPA+)
Numéro de commande 1313.1445.02
TD-SCDMA BS measurements
Numéro de commande 1313.1451.02
TD-SCDMA UE measurements
Numéro de commande 1313.1468.02
CDMA2000® BS measurements
Numéro de commande 1313.1474.02
CDMA2000® MS measurements
Numéro de commande 1313.1480.02
1xEV-DO BS measurements
Numéro de commande 1313.1497.02
1xEV-DO MS measurements
Numéro de commande 1313.1545.02
UTRA/LTE FDD BS measurements
Numéro de commande 1313.1551.02
EUTRA/LTE FDD UE measurements
Numéro de commande 1313.1568.02
EUTRA/LTE advanced and MIMO measurements (downlink)
Numéro de commande 1313.2487.02
EUTRA/LTE advanced UL measurements
Numéro de commande 1313.1574.02
EUTRA/LTE TDD BS measurements
Numéro de commande 1313.1580.02
EUTRA/LTE TDD uplink measurements
Numéro de commande 1331.6351.02
EUTRA/LTE NB-IoT downlink measurements
Numéro de commande 1331.7370.02
VERIZON 5GTF downlink measurements
Numéro de commande 1331.8060.02
VERIZON 5GTF uplink measurements
Numéro de commande 1338.3606.02
5G-NR downlink measurements
Numéro de commande 1338.3612.02
3GPP 5G-NR uplink measurements
Numéro de commande 1338.6486.02
5G NR combined ACLR/SEM/EVM measurements
Requires R&S®FSW-K144 or R&S®FSW-K145
Numéro de commande 1351.1355.02
5G NR multi-CC combined ACLR/SEM/EVM measurements
Requires R&S®FSW‑K147
Numéro de commande 1350.6624.02
5G NR Rel. 16 extension for uplink/downlink measurements
Numéro de commande 1350.7108.02
5G NR Rel. 17 extension for uplink/downlink measurements
Numéro de commande 1353.2642.02
O-RAN measurements
Requires R&S®FSW-K144 or R&S®FSW-K145
Numéro de commande 1313.1351.02
Bluetooth BR/EDR/LE measurements
Numéro de commande 1350.6930.02
HRP UWB measurements
Numéro de commande 1313.1500.02
WLAN 802.11a/b/g measurements
Numéro de commande 1313.1516.02
WLAN 802.11n measurements
Numéro de commande 1313.4209.02
WLAN 802.11ac measurements
Numéro de commande 1331.6345.02
WLAN 802.11ax measurements
Numéro de commande 1350.6730.02
WLAN 802.11be measurements
Numéro de commande 1321.5646.02
WLAN 802.11p measurements
Numéro de commande 1313.1639.02
WLAN 802.11ad measurements
Numéro de commande 1338.4902.02
WLAN 802.11ay measurements
Numéro de commande 1313.1339.02
Analog modulation analysis for AM/FM/φM
Numéro de commande 1325.2170.02
Amplifier measurements
Numéro de commande 1331.6845.02
Direct DPD measurements
Numéro de commande 1338.7230.02
Frequency response and group delay measurements
Numéro de commande 1345.1470.02
Memory polynomial DPD
(R&S®FSW-K18 and R&S®FSW-K18D options required)
Numéro de commande 1313.1380.02
Noise figure measurements
Numéro de commande 1313.1397.02
Phase noise measurements
Numéro de commande 1325.2893.02
Spurious measurements
Numéro de commande 1313.1400.02
EMI measurements
Numéro de commande 1331.5932.02
CISPR calibration for R&S®FSW-K54
Numéro de commande 1313.1416.02
Vector signal analysis
Numéro de commande 1338.4177.02
Multimodulation analysis
Numéro de commande 1338.3893.02
BER PRBS measurements
Numéro de commande 1313.1539.02
OFDM signal analysis
Flexible analysis of custom OFDM and DFT-OFDM (SC-FDMA) signals down to bit level.
Numéro de commande 1338.2716.02
User defined frequency correction by SnP file
Corrects frequency response (amplitude and phase) of measurement setup.
Numéro de commande 1350.6118.02
External frontend control
Numéro de commande 1353.2894.02
I/Q noise cancellation
Numéro de commande 1313.1322.02
Pulse measurements
Numéro de commande 1325.3783.02
Time sidelobe measurements
R&S®FSW-K6 option required.
Numéro de commande 1313.7495.02
Transient measurements
Numéro de commande 1322.9745.02
Transient chirp measurements
R&S®FSW-K60 option required.
Numéro de commande 1322.9916.02
Transient hop measurements
R&S®FSW-K60 option required.
Numéro de commande 1353.2413.02
Transient phase noise measurments
R&S®FSW-K60C or R&S®FSW-K60H option required.
Numéro de commande 1331.4388.02
VOR/ILS measurements
Numéro de commande 1313.4150.02
Multicarrier group delay measurements
Numéro de commande 1338.5896.02
Subspan measurement for group delay
Requires R&S®FSW-K17, R&S®FSW-B512, R&S®FSW-B512R, R&S®FSW-B1200, R&S®FSW-B2001, R&S®FSW-B800R, R&S®FSW-B4001, R&S®FSW-B6001 or R&S®FSW-B8001.
Numéro de commande 1331.8283.02
Noise power ratio measurements
Numéro de commande 1331.7387.02
OneWeb reverse link measurements
Numéro de commande 1325.4138.02
DOCSIS 3.1 OFDM downstream
Numéro de commande 1325.4144.02
DOCSIS 3.1 OFDMA upstream
Numéro de commande 1345.2253.02
Local VSE enabler
Numéro de commande 1331.7106.16
Real-time spectrum analyzer, 512 MHz, POI ≤ 15 µs
Includes 512 MHz analysis bandwidth and 200 MHz IF filter. Export license required.
Numéro de commande 1331.6400.16
Real-time spectrum analyzer, 800 MHz, POI ≤ 15 µs
Includes 2000 MHz analysis bandwidth. Not available in combination with R&S®FSW-B2000. Export license required.
Numéro de commande 1338.2700.02
160 MHz real-time measurement application, POI ≤ 15 µs
R&S®FSW-B160 or R&S®FSW-B320 required. Not available for R&S®FSW-B512/-B512R/-B1200/-B2001/-B800R. No export license required.
Numéro de commande 1338.4731.02
512 MHz real-time measurement application, POI > 15 μs
Requires R&S®FSW-B512.
Numéro de commande 1338.7801.02
800 MHz real-time measurement application, POI > 15 μs
Requires R&S®FSW-B1200 or R&S®FSW-B2001.
Numéro de commande 1350.6718.02
Health and Utilization Monitoring
Service für R&S®FSW
Numéro de commande 1313.3602.02
USB mass memory write protection
Numéro de commande 1322.7936.02
Security write protection for solid-state drive
Numéro de commande 1345.1011.06
Software
Brings the experience and power of Rohde & Schwarz signal analysis to PC and cloud
Numéro de commande 1309.9580.06
User-defined Frequency Correction by SnP File
Numéro de commande 1310.0002.03
Licence Dongle
Numéro de commande 1310.0002.04
Floating license dongle
Numéro de commande 1320.7622.81
Software maintenance
Numéro de commande 1320.7516.06
Pulse measurements application
Numéro de commande 1320.7868.06
Transient measurements
Transient analysis
Numéro de commande 1320.7874.06
Transient chirp measurements
Transient analysis, requires R&S®VSE-K60
Numéro de commande 1320.7880.06
Transient hop measurements
Transient analysis, requires R&S®VSE-K60
Numéro de commande 1320.7539.06
Analog modulation analysis (AM/FM/φM)
Modulation analysis for AM/FM/φM modulated single carriers
Numéro de commande 1320.7522.06
Vector signal analysis
Numéro de commande 1320.7922.06
OFDM signal analysis
Numéro de commande 1345.1434.06
Amplifier measurements
Numéro de commande 1345.1440.06
Direct DPD measurements
Numéro de commande 1345.1457.06
Frequency response measurements
Numéro de commande 1345.1492.06
Memory polynomial DPD
Numéro de commande 1345.1211.06
Multi-modulation analysis
R&S®VSE-K70 option required
Numéro de commande 1345.1228.06
BER PRBS measurements
R&S®VSE-K70 option required
Numéro de commande 1320.7574.06
GSM measurements
GSM/EDGE/ EDGE Evolution
Numéro de commande 1320.7580.06
3GPP FDD measurements
WCDMA signal analysis
Numéro de commande 1320.7545.06
EUTRA/LTE FDD uplink and downlink measurement application
LTE signal analysis
Numéro de commande 1320.7551.06
EUTRA/LTE advanced and MIMO (downlink)
LTE signal analysis
Numéro de commande 1320.7568.06
EUTRA/LTE TDD uplink and downlink measurement application
LTE signal analysis
Numéro de commande 1320.7900.06
EUTRA/LTE
Narrowband IoT analysis
Numéro de commande 1309.9574.06
5G NR uplink and downlink measurement application
Numéro de commande 1350.7020.06
O-RAN measurements
Numéro de commande 1320.7597.06
IEEE 802.11a/b/g measurements
WLAN signal analysis
Numéro de commande 1320.7680.06
IEEE 802.11p measurements
WLAN signal analysis
Numéro de commande 1320.7600.06
IEEE 802.11n measurements
WLAN signal analysis
Numéro de commande 1320.7616.06
IEEE 802.11ac measurements
WLAN signal analysis
Numéro de commande 1345.1411.06
IEEE 802.11ax measurements
WLAN signal analysis
Numéro de commande 1345.1463.06
HRP UWB measurements
Numéro de commande 1048.0171.02
Harmonic Mixer 40 GHz to 60 GHz (U band)
Numéro de commande 3638.2240.02
Harmonic Mixer 50 GHz to 75 GHz (wideband signal analysis)
Numéro de commande 3638.2270.02
Harmonic Mixer 60 GHz to 90 GHz (wideband signal analysis)
Numéro de commande 3638.2292.02
Harmonic Mixer 75 GHz to 110 GHz (wideband signal analysis)
Numéro de commande 3622.0708.02
Harmonic Mixer 90 GHz to 140 GHz
Numéro de commande 3622.0714.02
Harmonic Mixer 110 GHz to 170 GHz
Numéro de commande 3593.3250.02
Harmonic Mixer 140 GHz to 220 GHz
Numéro de commande 3593.3267.02
Harmonic Mixer 220 GHz to 325 GHz
Numéro de commande 1338.8008.18
Smart noise source 10 MHz to 18 GHz
Numéro de commande 1338.8008.26
Smart noise source 10 MHz to 26.5 GHz
Numéro de commande 1338.8008.40
Smart noise source 100 MHz to 40 GHz
Numéro de commande 1338.8008.55
Smart noise source 100 MHz to 55 GHz
Numéro de commande 1338.8008.67
Smart noise source 100 MHz to 67 GHz
Numéro de commande 1338.8008.90
Smart noise source 60 GHz to 90 GHz
Numéro de commande 1338.8008.11
Smart noise source 75 GHz to 110 GHz
Produits associés
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz
1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").
2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.
3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.
4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.
5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :
Prix : 1x oscilloscope numérique R&S®RTB2000
6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.
7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.
8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.
9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.
10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.
11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.
12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.
13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.