Key Facts

  • Supports multiple USB protocols, including USB1.1/ 2.0 /3.2 Gen1 & 2/ HSIC & SSIC/ Power Delivery
  • Bus configuration in seconds due to the Auto detection of the data rate and threshold
  • Display of decoded protocol as color-coded honeycomb in the waveform diagram or in tabular format
  • Reliable triggering on protocol details such as frame start, frame content and errors
  • Powerful search and navigate capabilities
  • Multi-domain icon

Brief description

The R&S®RTO and R&S®RTP oscilloscopes support triggering and decoding of all USB1.1 / 2.0/ 3.2 Gen 1/2, HSIC/SSIC and Power Delivery (PD) signals. You can set up the decoding within seconds. For detailed analysis, results can be viewed as color-coded protocol components and/or in table format. Errors are identified reliably and efficently using the hardware-accelerated trigger. You can trigger on protocol details such as frame start, frame content and errors.

Features & benefits

Fast configuration

Bus setup in seconds starting from the app cockpit
 

Starting from the oscilloscope's app cockpit, it only takes a few steps to configure the respective USB protocol. Once the protocol for decoding has been chosen, the connected channels selected and the correct levels set, decoding begins automatically.

Ingrandisci immagine

Easy and fast setup for decoding USB 3.2 Gen2

Color-coded protocol display

Protocol display as color-coded bus signals and in decode table
 

You can analyze the decoded protocol frames versus the original wavefrom by overlaying the waveform signal with color-coded protocol data. Address and data content can be displayed in hex, bin or ASCII format. Arrange the best overview on the display with the R&S SmartGrid. The protocol can also be displayed in a concise table.

Ingrandisci immagine

Decoded USB 3.2 Gen1 protocol frames are color coded for easier grasping of details.

Strong trigger capability

Strong trigger capability on start, stop, address, data and various error conditions

The protocol-specific trigger let you reliably isolate protocol events and errors. Thanks to high acquisition rates, Rohde & Schwarz oscilloscopes are ideal for finding errors quickly. The hardware-based triggering is available on specific protocol content, e.g. addresses, data and protocol errors.

Ingrandisci immagine

Select from various USB-PD protocol packet types for triggering.

Powerful search and navigate 

Search and navigate on recorded acquisitions

Comprehensive search functions simplify the analysis of long signal sequences. You can search for waveforms based on different criteria, such as signal faults or protocol content. All detected events are shown in a table with timestamps. The individual events can be examined in a zoom window with simple navigation between events.

Ingrandisci immagine

Powerful searching, even in long recordings. Example of a USB 3.2 Gen 2 signal.
 

Available models

Available models
Modelli
Serial standard
Search
Base unit

R&S®RTP-K570

Order Number 1803.6690.02

Serial standard
USB 1.1/ 2.0/ 3.2 Gen1 & Gen2 / HSIC / SSIC / PD
Search
Base unit

R&S®RTO6-K570

Order Number 1801.7077.02

Serial standard
USB 1.1/ 2.0/ 3.2 Gen1 / HSIC / SSIC / PD
Search
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.