R&S®NRPM OTA power measurement solution

R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution
Ingrandisci immagine
R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front high R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view

Key Facts

  • Frequency range from 18 GHz to 90 GHz
  • Extremely fast RX list mode
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay as well as automotive radar
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements

Designed for extremely accurate over-the-air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individually scalable OTA power measurement solution for benchtop applications or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz, it is perfect for over-the-air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of transmit antenna output power.

Features & benefits

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain, antenna patterns and mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, antenna pattern and diode detector are calibrated together. The user does not need to make any complicated system calibrations.

OTA power measurement system
Ingrandisci immagine

OTA power measurement system

Low-reflection antenna module

Low radar cross section avoids disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideal for screened environments, due to the virtual absence of reflections.

R&S®NRPM-A90 low-reflection antenna module
Ingrandisci immagine

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

The R&S®NRPM OTA power measurement solution uses a highly sensitive diode detector integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules can measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be precisely determined.

OTA power measurement solution, benchtop
Ingrandisci immagine

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the DUT receiver, it is necessary to know the exact OTA transmitted power at the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT for the transmit power calibration of the signal generator. The calibration uses an R&S®NRPM-A90/A90D antenna module, which is later replaced with the DUT. The receive power of the DUT is precisely detected.

System calibration for OTA receiver tests
Ingrandisci immagine

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power for all the antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane properly functions. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged on at least two horizontal planes.

TX beamforming verification
Ingrandisci immagine

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty (measurement distance 1 m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Product
Descrizione
R&S®NRPM-A90

Order Number 1426.7760.02

Descrizione

Single-polarized antenna module

Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power
measurements.

R&S®NRPM-A90D

Order Number 1426.7777.02

Descrizione

Dual-polarized antenna module

Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.

Sensor modules
Product
Descrizione
R&S®NRPM3

Order Number 1425.8563.02

Descrizione

Three-channel sensor module

R&S®NRPM3N

Order Number 1425.8592.02

Descrizione

Three Channel LAN Sensor Module

Interface for shielded RF test box
Product
Descrizione
R&S®NRPM-ZD3

Order Number 1425.8786.02

Descrizione

Filtered cable feedthrough

R&S®NRPM-ZKD3

Order Number 1436.2984.02

Descrizione

Interface cable

Interface for benchtop application
Product
Descrizione
R&S®NRPM-Z3

Order Number 1426.7602.02

Descrizione

Interface module

The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.

General accessories
Product
Descrizione
R&S®NRP-ZKU

Order Number 1419.0658.02

Descrizione

USB-A interface cable, length: 0.75 m

R&S®NRP-ZKU

Order Number 1419.0658.03

Descrizione

USB-A interface cable, length: 1.5 m

R&S®NRP-ZKU

Order Number 1419.0658.04

Descrizione

USB-A interface cable, length: 3 m

R&S®NRP-ZKU

Order Number 1419.0658.05

Descrizione

USB-A interface cable, length: 5 m

R&S®NRP-ZK6

Order Number 1419.0664.02

Descrizione

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Order Number 1419.0664.03

Descrizione

6-pole interface cable, length: 3 m

R&S®NRP-ZK6

Order Number 1419.0664.04

Descrizione

6-pole interface cable, length: 5 m

R&S®NRP-Z5

Order Number 1146.7740.02

Descrizione

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

R&S®NRPM-ZKT

Order Number 1425.8857.02

Descrizione

Trigger cable

Documentation
Product
Descrizione
R&S®DCV-1

Order Number 0240.2187.06

Descrizione

Documentation of calibration values

R&S®DCV-ZP

Order Number 1173.6506.02

Descrizione

Printout of DCV

Related videos

Funzionamento delle misure di potenza OTA

Questo video fornisce una breve introduzione tecnica alle misure di potenza in modalità over-the-air (OTA) e spiega in che modo siano diverse dalle tradizionali misure di potenza per via condotta.

mag 18, 2020

Utilizzo del sistema di misura R&S®NRPM

Questo breve video fornisce una breve introduzione al sistema di misura della potenza in modalità over-the-air (OTA) R&S®NRPM.

mag 18, 2020

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.