71 Resultados
R&S®RTP-K101: Compliance test for USB 3.2 Gen 1&2 - Fact Sheet Folletos y fichas técnicas
External frontends (FEs) extend the frequency range of the R&S®RTP high-performance oscilloscope. The basic functionality of an FE is similar to a spectrum analyzer. Depending on the selected radio frequency (RF), an intermediate frequency (IF) is transmitted to the oscilloscope. These frequencies are typically centered roughly at 5 GHz or 10 GHz.
R&S®RTP 오실로스코프는 진보된 사용자 인터페이스와 대형 스크린을 제공하는 고성능 오실로스코프입니다. 초소형 제품 크기와 우수한 성능, 사용자의 필요에 맞춰 활용 가능한 유연성을 동시에 지원합니다. R&S®RTP 오실로스코프는 실시간 신호 무결성을 분석하기 위한 최적의 솔루션입니다.
The R&S®RTP oscilloscope has an enhanced user interface and a large screen for the outstanding performance and flexibility you expect, combined with a very small footprint. This is perfect for signal integrity analysis in real time.
R&S®RTP high-perfomance oscilloscope - Fact sheet Folletos y fichas técnicas
R&S®RTP-B High-Performance Oscilloscope - Specifications Folletos y fichas técnicas Specifications
Sepa cómo Rohde & Schwarz y Eurofins Digital Testing proporcionan un kit de pruebas avanzado para los programas de ensayos de conformidad de interfaces de alta velocidad.
Actualización del firmware de R&S®RTO/RTP desde una versión anterior
RTO/RTP Configuración de los niveles de referencia para mediciones en la versión 5 del firmware
Al iniciar RTE/RTO/RTP, Windows pide usuario y contraseña. ¿Cómo puedo regresar a la función de inicio de sesión automático?
Escalamiento de mediciones de frecuencia RTE, RTO, RTP en ciclos/min
R&S®RTE/RTO/RTP - Exportación del historial a un archivo con comandos de control remoto
RTE/RTO/RTP: carga de un archivo de configuración con drivers de Labview
R&S®RTE/RTO/RTP: mediciones del nivel a una frecuencia designada en la transformada rápida de Fourier (FTT) por medio de comandos de control remoto.
R&S®RTE/RTO/RTP-B6: salida de una sola forma de onda en un modo único con comandos de control remoto RTE/RTO/RTP-B6 una sola forma de onda R&S®RTE/RTO/RTP-B6: salida de una sola forma de onda en un modo único con comandos de control remoto RTE/RTO/RTP-B6 una sola forma de onda Productos relacionados
Is it possible to do math operations on a measurement? For example measure the frequency but display the result as cycles per minute?
Estoy utilizando el modo ultra segmentación para minimizar el tiempo ciego. Pero no está indicado. ¿Existe algún modo de calcularlo?
Cuando utilizo la función zoom para ver el límite ascendente de una señal rectangular, observo oscilación transitoria la cual no es real, ver captura de pantalla. ¿Cuál es el motivo?
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
La secuencia SCPI para configuración y consulta de datos para la interfaz I/Q digital opción K11.
Cuando se conecta un monitor adicional mediante la interfaz HDMI, se pierde la funcionalidad táctil. ¿Cómo puedo hacer para que la funcionalidad táctil esté disponible otra vez?
Falla la conexión de R&S®ScopeSuite con RTO/RTP
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?