R&S®UMS12-OEM Monitoring System

Modular monitoring system with open programming interface

Este producto ya no está disponible
Tenga en cuenta los siguientes productos sucesores:

Key Facts

  • Frequency range from 100 kHz to 6 GHz
  • Open programming interface
  • Easy access to operating system and interfaces

Brief Description

The R&S®UMS12-OEM is a new member of the successful R&S®UMS family of compact monitoring systems. For the first time ever, an open interface is offered, allowing users or system houses to develop and implement their own control and application software.

Features

  • Easy access to software
  • Ideal for outdoor applications
  • Task-oriented technical concept
  • Application examples

Specifications

RF Data
Frequency range 100 kHz to 6 GHz
Tuning resolution 1 Hz

Key Facts

  • Frequency range from 100 kHz to 6 GHz
  • Open programming interface
  • Easy access to operating system and interfaces
  • Remote control capability
  • Weatherproof monitoring system

Brief Description

The R&S®UMS12-OEM is a new member of the successful R&S®UMS family of compact monitoring systems. For the first time ever, an open interface is offered, allowing users or system houses to develop and implement their own control and application software.

Features & Benefits

  • Easy access to software
    • Open programming interface
      The R&S®UMS12-OEM combines the advantages of the tried-and-tested R&S®UMS120 monitoring system with an open programming interface.

    • Easy access to operating system (Windows XP Embedded)
      The operating system (Windows XP Embedded) and the interfaces to the RF frontend and communications module are easily accessible. The thorough documentation and interface description enable users to develop control software that meets customer-specific requirements. Depending on the individual requirements, it is possible to run various applications simultaneously. The modules allowing communications via LAN and mobile radio can also be used for application development.

    • Optional development kit available
      The optional R&S®UMS12-Kit includes an adapter with cables that are connected to the open unit. One DVI and two USB interfaces are available on the adapter. The monitor, keyboard and mouse are directly connected to the R&S®UMS12-OEM, which considerably facilitates development and subsequent maintenance. The kit also includes a CD containing the manual as well as the current factory default image of the R&S®UMS12-OEM CF card. With this card, an image can be played back to the R&S®UMS12-OEM (e.g. to restore the Rohde & Schwarz delivery state during system integration).

  • Ideal for outdoor applications
    • Weatherproof monitoring system with lockable door
      A cabinet protects the electronic assemblies of the R&S®UMS12-OEM reliably against bad weather. A lockable door provides access to the fuses, the PRESET key and the SIM card holder of the optional mobile radio module.

    • External connectors on bottom of housing
      The sockets for connecting external components are located on the bottom. They include the sockets for two receiving antennas, one communications antenna, Ethernet LAN, DC and AC power supply as well as protective ground. A DC output socket allows the connection of active antennas via an optional DC feed.

    • Integrated heating with protection against overheating
      The integrated heating allows outdoor applications down to –40 °C. Moreover, the built-in electronic components are protected against any overtemperature that might be generated inside the R&S®UMS12-OEM. When a temperature of approx. +75 °C is reached inside the system, the modules are switched off.

    • Additional protection against bad weather provided by (optional) all-weather cabinet
      The optional R&S®UMS12-B1 all-weather cabinet additionally protects the system against sunlight, bad weather conditions and mechanical stress. The R&S®UMS12-OEM together with the R&S®UMS12-B1 can be mounted on walls or round tubes using the supplied holders.

  • Task-oriented technical concept
    • Wide frequency range from 100 kHz to 6 GHz
      This means that especially the range above 3 GHz, i.e. the limit of conventional receivers, is also available. Signals such as WLAN or WiMAX can be detected and monitored reliably.

    • Universal power supply concept
      The R&S®UMS12-OEM comes with a universal power supply concept that allows the system to operate on AC (100 V to 240 V, 50 Hz to 60 Hz) as well as DC supply voltages (10 V to 30 V). The two power supply sources can also be connected in parallel, enabling uninterrupted monitoring system operation if the primary supply fails.

    • Minimum power consumption
      Special emphasis has been placed on minimum power consumption. For ambient temperatures above 0 °C, power consumption is as low as approx. 25 W. Additional power is needed only at very low temperatures for heating the system. This means that the R&S®UMS12-OEM can operate on its own for a long period of time if batteries or solar cells are used.

    • Versatile remote control capabilities for remote operation
      Since the R&S®UMS12-OEM requires no local control elements, it can be placed at an optimum monitoring site while the operator remote-controls it from an office, for example. The R&S®UMS12-OEM is usually connected to a control center via the integrated Ethernet LAN interface. Optionally, communications can also be enabled via mobile radio networks. Communications modules to meet various standards (GSM, CDMA, etc.) are available ex factory.

    • Compact design
      The main components of the R&S®UMS12-OEM are the RF frontend with an integrated signal peprocessing unit and a processor module with an embedded operating system. The RF frontend, which is provided with two antenna inputs, processes the received signals, demodulates them if necessary and routes them on to the processor module. The consistent module design considerably reduces the system's size and power consumption.

    • Extensive range of accessories
      A variety of monitoring antennas are available as accessories. Depending on the application, active or passive antennas can be selected for various frequency ranges and polarizations. Material for mounting the system as well as antenna cables of different length are also provided. To connect active antennas, a DC voltage coupler for supply purposes is available. An all-weather cabinet for demanding environmental conditions, a grounding kit and useful tools round out the range of accessories.

  • Application examples

    The most typical applications include the following:

    • Automated measuring and monitoring tasks
    • Radiomonitoring covering large areas using the appropriate number of R&S®UMS12-OEM systems (national borders, coastlines, harbors, military training grounds, large industrial areas, etc.)
    • Detection of signals that might impair the sensitivity of communications and radiolocation systems (e.g. around airports)
    • Monitoring of licensed transmitter systems for compliance with operating parameters
    • Monitoring of rooms and buildings to detect the use of illegal transmitters (e.g. airports, hospitals)
    • Detection of interferences and other types of disturbance
    • Mobile search for new signals and monitoring of existing signals with the R&S®UMS12-OEM integrated in vehicles

    Further customer-specific applications can be implemented via the open interface.

Specifications

RF data
Frequency range 100 kHz to 6 GHz
Tuning resolution 1 Hz
VSWR ≤2.5
Second-order intercept (SOI) ≥180 dbμV (with attenuation)
Third-order intercept (TOI) ≥150 dbμV (with attenuation)
IF bandwidths 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 200 kHz, 300 kHz, 1 MHz
Demodulation AM, FM
Antenna inputs 2 × N female, 50 Ω
Connector for communications antenna GSM 900/1800, GSM 850/1900, CDMA 800/1900, N female
General data
DC input 7-contact circular connector
AC input 4-contact circular connector
Temperature range operating
with R&S®UMS12-B1 option
storage
–30 °C to +40 °C (no exposure to direct sunlight)
–40 °C to +55 °C (no exposure to direct sunlight)
–40 °C to +80 °C
Protection class IP54
Relative humidity 95 % cyclic test, at +25 °C/+40 °C
Vibration sinusoidal
random
5 Hz to 150 Hz
10 Hz to 500 Hz
Shock shock spectrum 40 g
EMC ETSI EN301489-1 V 1.61 (09/2005), EN301489-22 V 1.3.1 (11/2003), EN55022:1998 + A1:1999 + A2:2003, EN300339:1998 – cabinet radiation only
(in line with R&TTE Directive 1999/5/EC)
Electrical safety EN61010 edition 3/2003
MTBF 21500 h
Power supply AC voltage
DC voltage
power consumption

100 V to 240 V, 50 to 60 Hz
10 V to 30 V
typ. 25 VA/25 W (at ambient temperature ≥0 °C)
max. 200 VA/125 W
(including heating at ambient temperature <0 °C)
Weight base unit
with R&S®UMS12-B1 option
8 kg (17.64 lb)
12.2 kg (26.90 lb)
Dimensions W × H × D including connectors
W × H × D with R&S®UMS12-B1 option
300 mm × 445 mm × 175 mm
(11.81 in × 17.52 in × 6.89 in)
380 mm × 530 mm × 240 mm
(14.96 in × 20.87 in × 9.45 in)
Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar demostración

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.

Introduzca el país.
Permiso de marketing

Deseo recibir información de Rohde & Schwarz por


¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para prueba y medición, comunicaciones seguras, monitoreo y pruebas de redes, broadcast y media así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar presupuesto

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.
Introduzca el número de teléfono.

Introduzca el país.
Permiso de marketing

Deseo recibir información de Rohde & Schwarz por


¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para prueba y medición, comunicaciones seguras, monitoreo y pruebas de redes, broadcast y media así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar información

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.

Introduzca el país.
Permiso de marketing

Deseo recibir información de Rohde & Schwarz por


¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para prueba y medición, comunicaciones seguras, monitoreo y pruebas de redes, broadcast y media así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
International Website