R&S®NGU source measure units, front view R&S®NGU source measure units, front view R&S®NGU source measure units, front low R&S®NGU source measure units, side view R&S®NGU source measure units, side view R&S®NGU source measure units, side view R&S®NGU source measure units, back view R&S®NGU source measure units, hero view

Key Facts

  • Two/four quadrants: operates as source and sink
  • High speed data acquisition (FastLog function)
  • Voltage priority and current priority mode
  • High-capacitance mode
  • Intuitive, price-transparent online product configurator

The top-class in supplying power

The extremely high accuracy and fast load recovery times make R&S®NGU source measure units (SMU) perfect for challenging applications, such as:
- battery and power consumption tests
- supplying wireless devices with power
- simulation of voltage drops
A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The short recovery times enable the instruments to handle fast load changes when mobile communications devices switch from sleep to transmit mode. Every detail is detected down to 2 μs resolution with high speed data acquisition. R&S®NGU source measure units have two or four quadrant architecture to function both as a source and a sink.
Configure your own R&S®NGU SMU with our online configurator tool and benefit from full price transparency, ease of configuration along with fast processing and shipment through an authorized distribution partner of your choice
Click "Configure and quote" and start configuration now.

Caractéristiques & avantages

Two/four quadrants: operates as source and sink

Simulates batteries or loads

The two/four-quadrant architecture of these source measure units can function as a source and a sink to simulate batteries or loads. The SMU automatically switches from source mode to sink mode as soon as the externally applied voltage exceeds the set nominal voltage. With its four-quadrant architecture, the R&S®NGU401 can supply positive or negative voltages or currents and can act as a source or sink in both polarities.

Four-quadrant architecture of the R&S®NGU401
Open Lightbox

Four-quadrant architecture of the R&S®NGU401

R&S®NGU supplies positive or negative voltage in source or sink mode.

High speed data acquisition

FastLog function

The R&S®NGU source measure units offer the FastLog function to capture voltage and current measurement results. This data can be stored on an external USB storage device or transferred to an external PC via USB or LAN. With an acquisition rate of up to 500 ksample/s, voltage and current results are available every 2 μs.

FastLog high speed data acquisition
Open Lightbox

FastLog high speed data acquisition

The FastLog function follows voltage/current variations with a resolution of up to 2 μs.

Voltage priority and current priority mode

Optimized for voltage/current regulation

In voltage priority mode, fast voltage regulation provides short recovery times of less than 30 μs. Current regulation is designed to be somewhat slower to avoid oscillation. When precise and quick current regulation is desired, the R&S®NGU source measure units can be operated in current priority mode. Optimized for fast current regulation (load recovery time < 50 μs), this mode allows tasks such as LED testing, which are sensitive to even short current spikes.

Voltage/current priority mode
Open Lightbox

Voltage/current priority mode

The standard mode provides fast voltage regulation when there is risk of current overshoot. The special mode has fast and risk-free current regulation.

High-capacitance mode

Compensate capacitors

Typical measurement configurations often have capacitance at the DUT input. Connecting the power supply with leads causes low pass behavior from the leads and capacitance. In high-capacitance mode, R&S®NGU source measure units compensate for the capacitance and display the current directly at the DUT.

Fast load regulation

Handles fast load changes

Consumer electronics such as mobile phones and IoT devices require very little power in sleep mode. However, the current increases abruptly as soon as the device switches to transmit mode. A power supply for these DUTs must handle load changes from a few nA to the ampere range without creating voltage drops or overshoots.

Optimized load recovery time
Open Lightbox

Optimized load recovery time

Power supplies often respond to load changes with overshoot and slow recovery times. The R&S®NGU source measure units have recovery times of < 30 μs.

Easy to use, price transparent configurator

We help customers choose the right T&M instrument quickly, easily and with full price transparency. The R&S®NGU and other instruments from the R&S®Essentials portfolio can now be configured online, providing the following benefits:
- user-friendly and easy to navigate configurator
- full cost transparency at every configuration step
- fast order processing through authorized distribution partners 
- next-day delivery from selected partners

Available models

Available models
Modèles
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Commençant à

R&S®NGU201

Numéro de commande 3639.3763.02

Number of output channels
1
Max. output power
60 W
Output voltage per channel
0 V to 20 V
Output current per channel
≤ 6 V: 8 A
> 6 V: 3 A
Commençant à
Prix sur demande

R&S®NGU401

Numéro de commande 3639.3763.03

Number of output channels
1
Max. output power
60 W
Output voltage per channel
-20 V to +20 V
Output current per channel
≤ 6 V: ±8 A
> 6 V: ±3 A
Commençant à
Prix sur demande

R&S®NGU411

Numéro de commande 3639.3763.04

Number of output channels
1
Max. output power
20 W
Output voltage per channel
-20 V to +20 V
Output current per channel
≤ 10 V: ±2 A
> 10 V: ±1 A
Commençant à
Prix sur demande

Available options

Hardware options
Produit
Désignation
R&S®NGU-B105

Numéro de commande 3661.0763.02

Désignation

IEEE-488 (GPIB) interface

Software options
Produit
Désignation
R&S®NGU-K103

Numéro de commande 3662.9335.02

Désignation

Digital trigger I/O

R&S®NGU-K104

Numéro de commande 3663.0390.02

Désignation

Digital voltmeter function (R&S®NGU201 only)

R&S®NGU-K106

Numéro de commande 3663.0625.02

Désignation

Battery simulation (R&S®NGU201 only)

General accessories
Produit
Désignation
R&S®HZN96

Numéro de commande 3638.7813.02

Désignation

19'' rack adapter, 2HU

Related video

Webpage, VNC & FTP on R&S®DC Power Supplies

Learn how easy it is to control and operate our instrument from any location via ethernet-based remote services

High Precision Power Supplies

The R&S®NGM/L/U come with a linear design, 2 or 4-quadrant operation, high readback resolution, and advanced functionalities.

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.